Electrochemical detection of creatinine at picomolar scale with an extended linear dynamic range in human body fluids for diagnosis of kidney dysfunction

IF 5.7 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Sanya Khursheed , Sumera Sarwar , Dilshad Hussain , Muhammad Raza Shah , Jiri Barek , Muhammad Imran Malik
{"title":"Electrochemical detection of creatinine at picomolar scale with an extended linear dynamic range in human body fluids for diagnosis of kidney dysfunction","authors":"Sanya Khursheed ,&nbsp;Sumera Sarwar ,&nbsp;Dilshad Hussain ,&nbsp;Muhammad Raza Shah ,&nbsp;Jiri Barek ,&nbsp;Muhammad Imran Malik","doi":"10.1016/j.aca.2025.343978","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Creatinine levels in different body fluids can serve as an important biomarker for kidney functioning relevant to prostate cancer and chronic kidney disease (CKD). Creatinine levels vary in concentration in different body fluids, such as blood, urine, and saliva. Unlike previously reported sensors, the developed creatinine sensor can be employed for all levels of creatinine in samples of real patients.</div></div><div><h3>Results</h3><div>In this study, an efficient voltammetric sensor for creatinine is developed by modifying a glassy carbon electrode (GCE) with poly (ethyleneimine) (PEI) capped silver nanoparticles at titanium dioxide (PEI-AgNPs)/TiO<sub>2</sub>, i.e., titanium dioxide (TiO<sub>2</sub>)/graphene oxide (GO) nanocomposites (Ag@GO/TiO<sub>2</sub>-GCE). The Ag@GO/TiO<sub>2</sub> nanocomposite was characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), thermal gravimetric analysis (TGA), X-ray diffraction (XRD), transmission electron microscopy (TEM), dynamic light scattering (DLS), zeta potential, Fourier transform infrared (FT-IR) spectroscopy, and UV–Vis spectrophotometry. Various voltammetric techniques namely cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry (CA), and differential pulse voltammetry (DPV) were employed. The Ag@GO/TiO<sub>2</sub>-GCE demonstrated good selectivity, stability, and a quick response time of 1.0 s for creatinine. An extended linear dynamic range (LDR) of creatinine from 0.01 pM (DPV) to 1.0 M (CV) based on different voltammetric techniques is imperative for detecting diverse creatinine levels in various body fluids. The LOD and LOQ of the developed creatinine detection method were found to be 1.15 pM and 3.5 pM, respectively. The electrochemical sensor exhibited an exceptionally high sensitivity of 15.74 μApM<sup>−1</sup>cm<sup>−2</sup>.The body fluids from healthy volunteers were spiked with a known amount of creatinine to evaluate sensor efficiency in the context of recovery. Finally, blood serum, saliva, and urine samples of kidney patients were analyzed for creatinine levels.</div></div><div><h3>Significance</h3><div>An important merit of the developed creatinine sensor is its ability for non-invasive point-of-care diagnosis in saliva with more than 90 % recovery. The comparison of the developed method with the standard Jaffes' colorimetric method endorsed its reliability and extended ability for the samples where Jaffes’ method fails. The low LOD, high sensitivity, extended LDR, and low-cost render the possibility of adopting this method for point-of-care diagnosis.</div></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"1353 ","pages":"Article 343978"},"PeriodicalIF":5.7000,"publicationDate":"2025-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267025003721","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Creatinine levels in different body fluids can serve as an important biomarker for kidney functioning relevant to prostate cancer and chronic kidney disease (CKD). Creatinine levels vary in concentration in different body fluids, such as blood, urine, and saliva. Unlike previously reported sensors, the developed creatinine sensor can be employed for all levels of creatinine in samples of real patients.

Results

In this study, an efficient voltammetric sensor for creatinine is developed by modifying a glassy carbon electrode (GCE) with poly (ethyleneimine) (PEI) capped silver nanoparticles at titanium dioxide (PEI-AgNPs)/TiO2, i.e., titanium dioxide (TiO2)/graphene oxide (GO) nanocomposites (Ag@GO/TiO2-GCE). The Ag@GO/TiO2 nanocomposite was characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), thermal gravimetric analysis (TGA), X-ray diffraction (XRD), transmission electron microscopy (TEM), dynamic light scattering (DLS), zeta potential, Fourier transform infrared (FT-IR) spectroscopy, and UV–Vis spectrophotometry. Various voltammetric techniques namely cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry (CA), and differential pulse voltammetry (DPV) were employed. The Ag@GO/TiO2-GCE demonstrated good selectivity, stability, and a quick response time of 1.0 s for creatinine. An extended linear dynamic range (LDR) of creatinine from 0.01 pM (DPV) to 1.0 M (CV) based on different voltammetric techniques is imperative for detecting diverse creatinine levels in various body fluids. The LOD and LOQ of the developed creatinine detection method were found to be 1.15 pM and 3.5 pM, respectively. The electrochemical sensor exhibited an exceptionally high sensitivity of 15.74 μApM−1cm−2.The body fluids from healthy volunteers were spiked with a known amount of creatinine to evaluate sensor efficiency in the context of recovery. Finally, blood serum, saliva, and urine samples of kidney patients were analyzed for creatinine levels.

Significance

An important merit of the developed creatinine sensor is its ability for non-invasive point-of-care diagnosis in saliva with more than 90 % recovery. The comparison of the developed method with the standard Jaffes' colorimetric method endorsed its reliability and extended ability for the samples where Jaffes’ method fails. The low LOD, high sensitivity, extended LDR, and low-cost render the possibility of adopting this method for point-of-care diagnosis.

Abstract Image

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信