{"title":"One-year outcomes of biological mesh in hiatal hernia repair: a real-world study.","authors":"Xianggang Huang, Xiangyu Shao, Junsheng Li","doi":"10.1007/s10029-025-03316-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The placement of synthetic mesh during laparoscopic hiatal hernia repair has been verified to reduce postoperative recurrence, but mesh erosion and other related complications may occur to synthetic mesh, and our aim was to verify the safety and efficacy of biological mesh in hiatal hernia repair.</p><p><strong>Methods: </strong>Patients with hiatal hernia who were treated at a tertiary teaching university hospital from December 2020 to May 2023 were prospectively included in this study. General clinical data, hernia-related data, and intraoperative data were collected, and the patients were followed up at 1, 3, 6, and 12 months after surgery, after 12 months, follow-up as needed for primary outcome until September 2024. The following parameters were recorded during follow-up visit: gastroesophageal reflux symptoms, Gastroesophageal reflux disease-Health related quality of life (GERD-HRQL) questionnaire, postoperative recurrence, mesh-related complications and patients' overall satisfaction.</p><p><strong>Results: </strong>A total of 82 patients with hiatal hernia were included in this study. The mean age of the patients was 62.68 ± 15.93 years, mean BMI 24.81 ± 4.05 kg/m<sup>2</sup>, the average operation time was 128.21 ± 39.20 min. There was statistically significant improvement of GERD symptom postoperative (p<0.05). 72 cases (93.5%) were rated as \"Great\" on the GERD-HRQL at the 12 months after surgery; 65 cases (84.4%) were rated as \"very satisfactory\" on the overall satisfaction scale at the 12 months after surgery. 6 patients (7.3%) experienced recurrences, with no mesh-related complications reported during the follow-up.</p><p><strong>Conclusion: </strong>At a mean follow-up of 25.43 ± 10.38 months, the present study showed that laparoscopic hiatal hernia repair with biologic mesh results in low rates of 1-year recurrence and complications and increased patient satisfaction.</p>","PeriodicalId":13168,"journal":{"name":"Hernia","volume":"29 1","pages":"123"},"PeriodicalIF":2.6000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hernia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10029-025-03316-9","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The placement of synthetic mesh during laparoscopic hiatal hernia repair has been verified to reduce postoperative recurrence, but mesh erosion and other related complications may occur to synthetic mesh, and our aim was to verify the safety and efficacy of biological mesh in hiatal hernia repair.
Methods: Patients with hiatal hernia who were treated at a tertiary teaching university hospital from December 2020 to May 2023 were prospectively included in this study. General clinical data, hernia-related data, and intraoperative data were collected, and the patients were followed up at 1, 3, 6, and 12 months after surgery, after 12 months, follow-up as needed for primary outcome until September 2024. The following parameters were recorded during follow-up visit: gastroesophageal reflux symptoms, Gastroesophageal reflux disease-Health related quality of life (GERD-HRQL) questionnaire, postoperative recurrence, mesh-related complications and patients' overall satisfaction.
Results: A total of 82 patients with hiatal hernia were included in this study. The mean age of the patients was 62.68 ± 15.93 years, mean BMI 24.81 ± 4.05 kg/m2, the average operation time was 128.21 ± 39.20 min. There was statistically significant improvement of GERD symptom postoperative (p<0.05). 72 cases (93.5%) were rated as "Great" on the GERD-HRQL at the 12 months after surgery; 65 cases (84.4%) were rated as "very satisfactory" on the overall satisfaction scale at the 12 months after surgery. 6 patients (7.3%) experienced recurrences, with no mesh-related complications reported during the follow-up.
Conclusion: At a mean follow-up of 25.43 ± 10.38 months, the present study showed that laparoscopic hiatal hernia repair with biologic mesh results in low rates of 1-year recurrence and complications and increased patient satisfaction.
期刊介绍:
Hernia was founded in 1997 by Jean P. Chevrel with the purpose of promoting clinical studies and basic research as they apply to groin hernias and the abdominal wall . Since that time, a true revolution in the field of hernia studies has transformed the field from a ”simple” disease to one that is very specialized. While the majority of surgeries for primary inguinal and abdominal wall hernia are performed in hospitals worldwide, complex situations such as multi recurrences, complications, abdominal wall reconstructions and others are being studied and treated in specialist centers. As a result, major institutions and societies are creating specific parameters and criteria to better address the complexities of hernia surgery.
Hernia is a journal written by surgeons who have made abdominal wall surgery their specific field of interest, but we will consider publishing content from any surgeon who wishes to improve the science of this field. The Journal aims to ensure that hernia surgery is safer and easier for surgeons as well as patients, and provides a forum to all surgeons in the exchange of new ideas, results, and important research that is the basis of professional activity.