Adult national diagnostic reference levels for common computed tomography examinations in Zambia: A preliminary study with findings from public hospitals

IF 2.5 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
S. Kafwimbi , J.M. Sichone , F. Munsanje , O. Sutherland , O. Bwanga , B. Ohene-Botwe , S.M. Munsaka
{"title":"Adult national diagnostic reference levels for common computed tomography examinations in Zambia: A preliminary study with findings from public hospitals","authors":"S. Kafwimbi ,&nbsp;J.M. Sichone ,&nbsp;F. Munsanje ,&nbsp;O. Sutherland ,&nbsp;O. Bwanga ,&nbsp;B. Ohene-Botwe ,&nbsp;S.M. Munsaka","doi":"10.1016/j.radi.2025.102925","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>While many European and American countries have established national diagnostic reference levels (NDRLs), few African countries have. Therefore, this study aimed to propose adult NDRLs for common computed tomography (CT) examinations in Zambia.</div></div><div><h3>Methods</h3><div>1360 CT patient data for the brain, chest, abdomen and pelvis were collected from 10 public CT facilities. The CT images were assessed for acceptable image quality and patient anthropometry was done, with patients' anteroposterior diameter used as the patient parameter. NDRLs were set at the 75th percentile of the distribution of volume-based CT dose index (CTDI<sub>vol</sub>) and dose length product (DLP) and were compared to countries’ NDRLs.</div></div><div><h3>Results</h3><div>NDRLs for CTDI<sub>vol</sub> in mGy were calculated as follows; non-contrast brain 70.5, contrast brain 56.74, non-contrast chest 20.24, contrast chest 20, non-contrast abdomen/pelvis, 21.3, contrast abdomen/pelvic 21.3, non-contrast chest/abdomen/pelvis 20 and contrast chest/abdomen/pelvis 19.1. The corresponding NDRLs for DLP in mGy.cm are 1455, 1206, 745.8, DLP 666.7, 1103, 1103, 1237 and 1141. Variations in DLP values between facilities were statistically significant (<em>p</em> &lt; 0.0001). NDRLs for the brain and chest were higher than those from other countries but lower for the abdomen/pelvis and chest/abdomen/pelvis. Correlations between the CT scanner's number of detector rows and CTDI<sub>vol</sub> were (r = 0.08285, <em>p</em> &lt; 0.0.0022) and (r = 0.5038, <em>p</em> &lt; 0.0001) between patients' AP diameter and CTDI<sub>vol.</sub></div></div><div><h3>Conclusion</h3><div>The proposed NDRLs confirmed the need to optimise CT scan parameters and protocols in Zambia. Therefore, extensive training of all CT radiographers in optimising CT image acquisition parameters and regular dose audits is recommended.</div></div><div><h3>Implication of practice</h3><div>NDRLs will likely provide a benchmarking mechanism for dose optimisation practices among CT radiographers in Zambia and beyond.</div></div>","PeriodicalId":47416,"journal":{"name":"Radiography","volume":"31 3","pages":"Article 102925"},"PeriodicalIF":2.5000,"publicationDate":"2025-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1078817425000665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

While many European and American countries have established national diagnostic reference levels (NDRLs), few African countries have. Therefore, this study aimed to propose adult NDRLs for common computed tomography (CT) examinations in Zambia.

Methods

1360 CT patient data for the brain, chest, abdomen and pelvis were collected from 10 public CT facilities. The CT images were assessed for acceptable image quality and patient anthropometry was done, with patients' anteroposterior diameter used as the patient parameter. NDRLs were set at the 75th percentile of the distribution of volume-based CT dose index (CTDIvol) and dose length product (DLP) and were compared to countries’ NDRLs.

Results

NDRLs for CTDIvol in mGy were calculated as follows; non-contrast brain 70.5, contrast brain 56.74, non-contrast chest 20.24, contrast chest 20, non-contrast abdomen/pelvis, 21.3, contrast abdomen/pelvic 21.3, non-contrast chest/abdomen/pelvis 20 and contrast chest/abdomen/pelvis 19.1. The corresponding NDRLs for DLP in mGy.cm are 1455, 1206, 745.8, DLP 666.7, 1103, 1103, 1237 and 1141. Variations in DLP values between facilities were statistically significant (p < 0.0001). NDRLs for the brain and chest were higher than those from other countries but lower for the abdomen/pelvis and chest/abdomen/pelvis. Correlations between the CT scanner's number of detector rows and CTDIvol were (r = 0.08285, p < 0.0.0022) and (r = 0.5038, p < 0.0001) between patients' AP diameter and CTDIvol.

Conclusion

The proposed NDRLs confirmed the need to optimise CT scan parameters and protocols in Zambia. Therefore, extensive training of all CT radiographers in optimising CT image acquisition parameters and regular dose audits is recommended.

Implication of practice

NDRLs will likely provide a benchmarking mechanism for dose optimisation practices among CT radiographers in Zambia and beyond.
赞比亚成人普通计算机断层扫描检查的国家诊断参考水平:来自公立医院的初步研究结果
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiography
Radiography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.70
自引率
34.60%
发文量
169
审稿时长
63 days
期刊介绍: Radiography is an International, English language, peer-reviewed journal of diagnostic imaging and radiation therapy. Radiography is the official professional journal of the College of Radiographers and is published quarterly. Radiography aims to publish the highest quality material, both clinical and scientific, on all aspects of diagnostic imaging and radiation therapy and oncology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信