Evaluation of stapes image quality with ultra-high-resolution CT in comparison to cone-beam CT and high-resolution CT in cadaveric heads.

U Puel, S Boukhzer, M Doyen, G Hossu, F Boubaker, F Groubatch, A Blum, P A Gondim Teixeira, M Eliezer, C Parietti-Winkler, R Gillet
{"title":"Evaluation of stapes image quality with ultra-high-resolution CT in comparison to cone-beam CT and high-resolution CT in cadaveric heads.","authors":"U Puel, S Boukhzer, M Doyen, G Hossu, F Boubaker, F Groubatch, A Blum, P A Gondim Teixeira, M Eliezer, C Parietti-Winkler, R Gillet","doi":"10.3174/ajnr.A8748","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>The purpose of this study was to evaluate the ability of high-resolution (HR), ultra-high-resolution (UHR) with and without deep learning reconstruction (DLR), and cone-beam (CB) CT scanners to image the stapes using micro-CT as a reference.</p><p><strong>Materials and methods: </strong>11 temporal bone specimens were imaged using all imaging modalities. Subjective image analysis was performed by grading image quality on a Likert scale, and objective image analysis was performed by taking various measurements of the stapes superstructure and footplate. Image noise and radiation dose were also recorded.</p><p><strong>Results: </strong>The global image quality scores were all worse than micro-CT (<i>P</i> ≤ 0.01). UHR-CT with and without DLR had the second-best global image quality scores (<i>P</i> > 0.99), which were both better than CB-CT (<i>P</i> = 0.01 for both). CB-CT had a better global image quality score than HR-CT (<i>P</i> = 0.01). Most of the measurements differed between HR-CT and micro-CT (<i>P</i> ≤ 0.02), but not between UHR-CT with and without DLR, CB-CT, and micro-CT (<i>P</i> > 0.06). The air noise value of UHR-CT with DLR was not different from CB-CT (<i>P</i> = 0.49), but HR-CT and UHR-CT without DLR exhibited higher values than UHR-CT with DLR (<i>P</i> ≤ 0.001). HR-CT and UHR-CT with and without DLR yielded the same effective radiation dose values of 1.23 ± 0.11 (1.13-1.35) mSv, which was four times higher than that of CB-CT (0.35 ± 0 mSv, <i>P</i> ≤ 0.01).</p><p><strong>Conclusion: </strong>UHR-CT with and without DLR offers comparable objective image analysis to CB-CT while providing superior subjective image quality. However, this is achieved at the cost of a higher radiation dose. Both CB-CT and UHR-CT with and without DLR are more effective than HR-CT in objective and subjective image analysis.</p><p><strong>Abbreviations: </strong>CB: Cone beam; CT: Computed tomography; DLR: Deep learning reconstruction; HR: High-resolution; UHR: Ultra-high resolution.</p>","PeriodicalId":93863,"journal":{"name":"AJNR. American journal of neuroradiology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AJNR. American journal of neuroradiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3174/ajnr.A8748","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: The purpose of this study was to evaluate the ability of high-resolution (HR), ultra-high-resolution (UHR) with and without deep learning reconstruction (DLR), and cone-beam (CB) CT scanners to image the stapes using micro-CT as a reference.

Materials and methods: 11 temporal bone specimens were imaged using all imaging modalities. Subjective image analysis was performed by grading image quality on a Likert scale, and objective image analysis was performed by taking various measurements of the stapes superstructure and footplate. Image noise and radiation dose were also recorded.

Results: The global image quality scores were all worse than micro-CT (P ≤ 0.01). UHR-CT with and without DLR had the second-best global image quality scores (P > 0.99), which were both better than CB-CT (P = 0.01 for both). CB-CT had a better global image quality score than HR-CT (P = 0.01). Most of the measurements differed between HR-CT and micro-CT (P ≤ 0.02), but not between UHR-CT with and without DLR, CB-CT, and micro-CT (P > 0.06). The air noise value of UHR-CT with DLR was not different from CB-CT (P = 0.49), but HR-CT and UHR-CT without DLR exhibited higher values than UHR-CT with DLR (P ≤ 0.001). HR-CT and UHR-CT with and without DLR yielded the same effective radiation dose values of 1.23 ± 0.11 (1.13-1.35) mSv, which was four times higher than that of CB-CT (0.35 ± 0 mSv, P ≤ 0.01).

Conclusion: UHR-CT with and without DLR offers comparable objective image analysis to CB-CT while providing superior subjective image quality. However, this is achieved at the cost of a higher radiation dose. Both CB-CT and UHR-CT with and without DLR are more effective than HR-CT in objective and subjective image analysis.

Abbreviations: CB: Cone beam; CT: Computed tomography; DLR: Deep learning reconstruction; HR: High-resolution; UHR: Ultra-high resolution.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信