Anatomic characteristics of the vertebrobasilar artery: A three-dimensional reconstruction study based on computed tomography angiography.

IF 1.3 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL
Qing Chao, YuanLiang Hu, Biao Zhao, YuXi Sun, Hansheng Shu, DaWei Wang, Zhe Cheng
{"title":"Anatomic characteristics of the vertebrobasilar artery: A three-dimensional reconstruction study based on computed tomography angiography.","authors":"Qing Chao, YuanLiang Hu, Biao Zhao, YuXi Sun, Hansheng Shu, DaWei Wang, Zhe Cheng","doi":"10.1097/MD.0000000000041931","DOIUrl":null,"url":null,"abstract":"<p><p>The vertebrobasilar artery (VBA) exhibits substantial inter-individual variation that must be considered in diagnosis and surgical planning. We conducted 3-dimensional reconstruction of the bilateral VBA based on head and neck computed tomography angiography (CTA) to assess bilateral, individual, age-dependent, and sex-dependent differences in anatomical parameters. A retrospective study was performed. Individual 3-dimensional models of the VBA and skull were constructed and morphology evaluated based on head and neck CTA data from 199 adults. According to morphological and anatomical variation, the VBA was divided into 3 types: balanced, L, and S. The diameters and lengths of basilar and bilateral vertebral artery (VA) intracranial segments as well as VBA blending length, and bilateral distances of the vertebral arteries moving up the atlas were measured and statistically compared. The L-type was the most common VBA morphology, and anatomic type distribution differed significantly by age (P < .05). VA diameter was 3.34 ± 0.68 mm on the left side and 3.09 ± 0.71 mm on the right side, while bending length was 5.62 ± 3.35 mm on the left and 4.94 ± 3.41 mm on the right side. Balanced basilar arteries measured 3.41 ± 0.61 mm in diameter, 2.83 ± 0.33 cm in length, and 2.55 ± 2.45 mm in bending length. The L-type basilar artery measured 3.48 ± 0.71 mm in diameter, 3.06 ± 0.44 cm in length, and 2.78 ± 0.37 mm in bending length. Finally, S-type basilar arteries measured 3.84 ± 0.86 mm in diameter, 3.38 ± 0.61 cm in length, and 3.67 ± 4.39 mm in bending length. The distance traveled by the VA across the atlas differed significantly between left and right sides as well as between males and females (P < .05). The vertebrobasilar arteries in the general healthy population were successfully fused and 3-dimensionally reconstructed based on the CTA, and an observational study was conducted on their morphological and anatomical characteristics. Three-dimensional reconstruction of the VBA using CTA is feasible for anatomical research and also has diagnostic value for the variations and anatomical parameters of the VBA.</p>","PeriodicalId":18549,"journal":{"name":"Medicine","volume":"104 12","pages":"e41931"},"PeriodicalIF":1.3000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11936587/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MD.0000000000041931","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

The vertebrobasilar artery (VBA) exhibits substantial inter-individual variation that must be considered in diagnosis and surgical planning. We conducted 3-dimensional reconstruction of the bilateral VBA based on head and neck computed tomography angiography (CTA) to assess bilateral, individual, age-dependent, and sex-dependent differences in anatomical parameters. A retrospective study was performed. Individual 3-dimensional models of the VBA and skull were constructed and morphology evaluated based on head and neck CTA data from 199 adults. According to morphological and anatomical variation, the VBA was divided into 3 types: balanced, L, and S. The diameters and lengths of basilar and bilateral vertebral artery (VA) intracranial segments as well as VBA blending length, and bilateral distances of the vertebral arteries moving up the atlas were measured and statistically compared. The L-type was the most common VBA morphology, and anatomic type distribution differed significantly by age (P < .05). VA diameter was 3.34 ± 0.68 mm on the left side and 3.09 ± 0.71 mm on the right side, while bending length was 5.62 ± 3.35 mm on the left and 4.94 ± 3.41 mm on the right side. Balanced basilar arteries measured 3.41 ± 0.61 mm in diameter, 2.83 ± 0.33 cm in length, and 2.55 ± 2.45 mm in bending length. The L-type basilar artery measured 3.48 ± 0.71 mm in diameter, 3.06 ± 0.44 cm in length, and 2.78 ± 0.37 mm in bending length. Finally, S-type basilar arteries measured 3.84 ± 0.86 mm in diameter, 3.38 ± 0.61 cm in length, and 3.67 ± 4.39 mm in bending length. The distance traveled by the VA across the atlas differed significantly between left and right sides as well as between males and females (P < .05). The vertebrobasilar arteries in the general healthy population were successfully fused and 3-dimensionally reconstructed based on the CTA, and an observational study was conducted on their morphological and anatomical characteristics. Three-dimensional reconstruction of the VBA using CTA is feasible for anatomical research and also has diagnostic value for the variations and anatomical parameters of the VBA.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Medicine
Medicine 医学-医学:内科
CiteScore
2.80
自引率
0.00%
发文量
4342
审稿时长
>12 weeks
期刊介绍: Medicine is now a fully open access journal, providing authors with a distinctive new service offering continuous publication of original research across a broad spectrum of medical scientific disciplines and sub-specialties. As an open access title, Medicine will continue to provide authors with an established, trusted platform for the publication of their work. To ensure the ongoing quality of Medicine’s content, the peer-review process will only accept content that is scientifically, technically and ethically sound, and in compliance with standard reporting guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信