Factors Influencing Fluorescence-Activated Cell Sorting for Multiple Myeloma Fluorescence in situ Hybridization: Real-World Experience.

IF 4 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Jaeguk Choi, Kyunghee Yu, Seung-Tae Lee, Saeam Shin, Jong Rak Choi
{"title":"Factors Influencing Fluorescence-Activated Cell Sorting for Multiple Myeloma Fluorescence <i>in situ</i> Hybridization: Real-World Experience.","authors":"Jaeguk Choi, Kyunghee Yu, Seung-Tae Lee, Saeam Shin, Jong Rak Choi","doi":"10.3343/alm.2024.0582","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>FISH is the standard method for detecting cytogenetic abnormalities (CAs) in patients with multiple myeloma, and pre-enrichment of plasma cells is recommended to increase detection rates. However, optimal strategies to ensure sufficient plasma cell retrieval when standard enrichment techniques fail remain underexplored. We investigated factors influencing the success of fluorescence-activated cell sorting (FACS) and assessed the use of direct FISH in cases in which FACS failed.</p><p><strong>Methods: </strong>A retrospective analysis was conducted on 457 bone marrow samples submitted for FISH between November 2016 and May 2022. FACS was considered successful when plasma cells (CD38+ and CD138+ cells) constituted >1% of the total number of cells. Direct FISH was performed for samples with FACS failure.</p><p><strong>Results: </strong>FACS was successful in 70.9% of cases and had a high positivity rate (94.8%). Shorter sample transfer times significantly improved FACS success, with a 77.1% success rate for transfer times <2 hrs, compared with 67.8% for longer times (<i>P</i> =0.0388). Plasma cell percentage was a strong determinant of FACS success, with a median of 31.2% in successful cases versus 8.5% in failures (<i>P</i> <0.0001). Even when FACS failed, direct FISH detected CAs in 43.6% of cases.</p><p><strong>Conclusions: </strong>Plasma cell percentage and sample transfer time are critical factors influencing FACS success. While FACS-FISH demonstrates superior sensitivity in detecting CAs, direct FISH serves as a valuable alternative when FACS fails. These findings highlight the importance of optimizing sample handling and FISH protocols for accurate cytogenetic analysis of multiple myeloma.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2024.0582","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: FISH is the standard method for detecting cytogenetic abnormalities (CAs) in patients with multiple myeloma, and pre-enrichment of plasma cells is recommended to increase detection rates. However, optimal strategies to ensure sufficient plasma cell retrieval when standard enrichment techniques fail remain underexplored. We investigated factors influencing the success of fluorescence-activated cell sorting (FACS) and assessed the use of direct FISH in cases in which FACS failed.

Methods: A retrospective analysis was conducted on 457 bone marrow samples submitted for FISH between November 2016 and May 2022. FACS was considered successful when plasma cells (CD38+ and CD138+ cells) constituted >1% of the total number of cells. Direct FISH was performed for samples with FACS failure.

Results: FACS was successful in 70.9% of cases and had a high positivity rate (94.8%). Shorter sample transfer times significantly improved FACS success, with a 77.1% success rate for transfer times <2 hrs, compared with 67.8% for longer times (P =0.0388). Plasma cell percentage was a strong determinant of FACS success, with a median of 31.2% in successful cases versus 8.5% in failures (P <0.0001). Even when FACS failed, direct FISH detected CAs in 43.6% of cases.

Conclusions: Plasma cell percentage and sample transfer time are critical factors influencing FACS success. While FACS-FISH demonstrates superior sensitivity in detecting CAs, direct FISH serves as a valuable alternative when FACS fails. These findings highlight the importance of optimizing sample handling and FISH protocols for accurate cytogenetic analysis of multiple myeloma.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Laboratory Medicine
Annals of Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
8.30
自引率
12.20%
发文量
100
审稿时长
6-12 weeks
期刊介绍: Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信