An analytic linear relation between the imposed heat flux and the pipe-end temperature for flat heat pipes with porous wicks

IF 5 2区 工程技术 Q1 ENGINEERING, MECHANICAL
Salar Saadatian, Harris Wong
{"title":"An analytic linear relation between the imposed heat flux and the pipe-end temperature for flat heat pipes with porous wicks","authors":"Salar Saadatian,&nbsp;Harris Wong","doi":"10.1016/j.ijheatmasstransfer.2025.126950","DOIUrl":null,"url":null,"abstract":"<div><div>Flat heat pipes have been extensively used in thermal management of microelectronic devices. However, their heat-transfer mechanism has not been analyzed rigorously. A flat heat pipe can be separated into three sections: evaporator, adiabatic, and condenser. Heat is supplied to the evaporator and removed from the condenser. We consider a horizontal flat heat pipe with an idealized porous wick on either one or both walls. The pores in the wick are straight circular capillaries running along and across the wick and are filled with a partially-wetting liquid. The rest of the pipe is filled with its vapor. We assume that the heat transfer is one-dimensional, and the pore size is extremely small compared with the pipe length. Therefore, the pore-level phenomena can be studied separately from those at the pipe level. The analytic solution for the mass evaporative rate in a single pore is incorporated into the mass, momentum, and energy balances along the pipe. We take the evaporator to have the same length as the condenser which leads to skew-symmetric solutions. Hence, we only need to focus on the heated half of the pipe, and solve the steady-state problem with a specified heat flux <span><math><msup><mrow><mi>q</mi></mrow><mrow><mo>′</mo><mo>′</mo></mrow></msup></math></span> at the evaporator. We find for the first time an analytic linear relation between <span><math><msup><mrow><mi>q</mi></mrow><mrow><mo>′</mo><mo>′</mo></mrow></msup></math></span> and <span><math><mrow><mi>Δ</mi><mi>T</mi></mrow></math></span>, where <span><math><mrow><mn>2</mn><mi>Δ</mi><mi>T</mi></mrow></math></span> is the temperature difference between the two ends of the pipe. This analytic relation is validated by comparing with four published experiments. The analytic relation shows that to optimize the performance, a flat heat pipe should be designed with maximum wick porosity, liquid thermal conductivity, and number of evaporative pores, and minimum wick permeability.</div></div>","PeriodicalId":336,"journal":{"name":"International Journal of Heat and Mass Transfer","volume":"245 ","pages":"Article 126950"},"PeriodicalIF":5.0000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Heat and Mass Transfer","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0017931025002911","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Flat heat pipes have been extensively used in thermal management of microelectronic devices. However, their heat-transfer mechanism has not been analyzed rigorously. A flat heat pipe can be separated into three sections: evaporator, adiabatic, and condenser. Heat is supplied to the evaporator and removed from the condenser. We consider a horizontal flat heat pipe with an idealized porous wick on either one or both walls. The pores in the wick are straight circular capillaries running along and across the wick and are filled with a partially-wetting liquid. The rest of the pipe is filled with its vapor. We assume that the heat transfer is one-dimensional, and the pore size is extremely small compared with the pipe length. Therefore, the pore-level phenomena can be studied separately from those at the pipe level. The analytic solution for the mass evaporative rate in a single pore is incorporated into the mass, momentum, and energy balances along the pipe. We take the evaporator to have the same length as the condenser which leads to skew-symmetric solutions. Hence, we only need to focus on the heated half of the pipe, and solve the steady-state problem with a specified heat flux q at the evaporator. We find for the first time an analytic linear relation between q and ΔT, where 2ΔT is the temperature difference between the two ends of the pipe. This analytic relation is validated by comparing with four published experiments. The analytic relation shows that to optimize the performance, a flat heat pipe should be designed with maximum wick porosity, liquid thermal conductivity, and number of evaporative pores, and minimum wick permeability.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.30
自引率
13.50%
发文量
1319
审稿时长
41 days
期刊介绍: International Journal of Heat and Mass Transfer is the vehicle for the exchange of basic ideas in heat and mass transfer between research workers and engineers throughout the world. It focuses on both analytical and experimental research, with an emphasis on contributions which increase the basic understanding of transfer processes and their application to engineering problems. Topics include: -New methods of measuring and/or correlating transport-property data -Energy engineering -Environmental applications of heat and/or mass transfer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信