{"title":"Vessel density and retinal nerve fiber layer in pathological intraocular pressure.","authors":"Jakub Král, Ján Lešták, Martin Fůs","doi":"10.31348/2025/15","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of the study was to determine the correlation between intraocular pressure (IOP) and thickness of the retinal nerve fiber layer (RNFL), and vascular density (VD) in the optic nerve.</p><p><strong>Material and methodology: </strong>IOP was greater than 21 mmHg (21-36 mmHg) in all eyes and was measured as the result of an average of three measurements with the instrument Ocular Response Analyzer (ORA, Reichert). RNFL and VD thickness (in the papillary region of 4.5 x 4.5 mm) was measured with the instrument Avanti RTVue XR (Optovue). In the case of the VD, the scan area was further separated into individual anatomical segments. In the case of corrected RNFL (RNFLc), the VD value was subtracted from the total RNFL value. The relationship of IOP to VD, RNFL and RNFLc in each peripapillary segment was determined using a Pearson's correlation coefficient.</p><p><strong>Results: </strong>The most significant correlation with IOP was observed for small vessel VD in a full scan (r = -0.48) and VD in the IT segment (r = -0.48). A similar correlation was observed for IOP and RNFL (r = -0.42). No statistically significant correlation was observed for RNFLc.</p><p><strong>Conclusion: </strong>We demonstrated that VD values, specifically WI-VDs and peripapillary VDs in the IT segment, are significant markers for the early diagnosis of glaucoma.</p>","PeriodicalId":39839,"journal":{"name":"Ceska a Slovenska Oftalmologie","volume":"81 Ahead of Print","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceska a Slovenska Oftalmologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31348/2025/15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: The aim of the study was to determine the correlation between intraocular pressure (IOP) and thickness of the retinal nerve fiber layer (RNFL), and vascular density (VD) in the optic nerve.
Material and methodology: IOP was greater than 21 mmHg (21-36 mmHg) in all eyes and was measured as the result of an average of three measurements with the instrument Ocular Response Analyzer (ORA, Reichert). RNFL and VD thickness (in the papillary region of 4.5 x 4.5 mm) was measured with the instrument Avanti RTVue XR (Optovue). In the case of the VD, the scan area was further separated into individual anatomical segments. In the case of corrected RNFL (RNFLc), the VD value was subtracted from the total RNFL value. The relationship of IOP to VD, RNFL and RNFLc in each peripapillary segment was determined using a Pearson's correlation coefficient.
Results: The most significant correlation with IOP was observed for small vessel VD in a full scan (r = -0.48) and VD in the IT segment (r = -0.48). A similar correlation was observed for IOP and RNFL (r = -0.42). No statistically significant correlation was observed for RNFLc.
Conclusion: We demonstrated that VD values, specifically WI-VDs and peripapillary VDs in the IT segment, are significant markers for the early diagnosis of glaucoma.
期刊介绍:
- Redakce přijímá pouze práce vyhovující po odborné stránce, které jsou na odpovídající profesionální a formální úrovni. - Uveřejněná práce se stává majetkem časopisu, přetisknout její část nebo obrázek lze jen s citací původu. - Rukopis zasílejte v originále a dobře čitelné kopii (je nutná také kopie tabulek, legend, podle možnosti i obrázků). - Listy číslujte v pravém horním rohu a spojujte svorkou, nesešívejte. Přijímáme práce psané na jedné straně kvalitního bílého nelesklého papíru formátu A4 (neprůklepový) na psacím stroji nebo počítači s obvyklými typy.