{"title":"Near-infrared spectroscopy in perioperative medicine","authors":"Igor Feinstein, Martin S Angst","doi":"10.1136/bmj.r539","DOIUrl":null,"url":null,"abstract":"Current insights and remaining questions Near-infrared spectroscopy (NIRS), originally described in 1977, entered clinical practice as a non-invasive method to assess regional tissue oxygenation.1 This monitoring technique was initially used in high risk surgeries to measure cerebral oxygenation in real time. After encouraging results that linked intraoperative NIRS guided, goal directed treatment to improved neurological outcomes in cardiac surgery, NIRS use quickly expanded.234 This increased use has sparked the development of multiple competing clinically approved NIRS monitoring systems, highlighting the substantial market interest in this technology.5 Despite the widespread use of NIRS, negative findings from subsequent trials have raised concerns about whether NIRS monitoring truly improves outcomes.678 These concerns have prompted a debate regarding the surgical populations who might benefit from NIRS and the best practices for its use.9 In a linked research paper (doi:10.1136/bmj-2024-082104), Han and colleagues present noteworthy findings from the Bottomline-CS trial, which examined whether perioperative care guided by cerebral and peripheral tissue oximetry enhanced clinical outcomes in patients undergoing off-pump coronary artery bypass graft surgery …","PeriodicalId":22388,"journal":{"name":"The BMJ","volume":"28 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The BMJ","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmj.r539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Current insights and remaining questions Near-infrared spectroscopy (NIRS), originally described in 1977, entered clinical practice as a non-invasive method to assess regional tissue oxygenation.1 This monitoring technique was initially used in high risk surgeries to measure cerebral oxygenation in real time. After encouraging results that linked intraoperative NIRS guided, goal directed treatment to improved neurological outcomes in cardiac surgery, NIRS use quickly expanded.234 This increased use has sparked the development of multiple competing clinically approved NIRS monitoring systems, highlighting the substantial market interest in this technology.5 Despite the widespread use of NIRS, negative findings from subsequent trials have raised concerns about whether NIRS monitoring truly improves outcomes.678 These concerns have prompted a debate regarding the surgical populations who might benefit from NIRS and the best practices for its use.9 In a linked research paper (doi:10.1136/bmj-2024-082104), Han and colleagues present noteworthy findings from the Bottomline-CS trial, which examined whether perioperative care guided by cerebral and peripheral tissue oximetry enhanced clinical outcomes in patients undergoing off-pump coronary artery bypass graft surgery …