High performance charge detection mass spectrometry without ultra-high vacuum†

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2025-03-24 DOI:10.1039/D5AN00019J
Emeline Hanozin, Conner C. Harper, Jacob S. Jordan, Zachary M. Miller and Evan R. Williams
{"title":"High performance charge detection mass spectrometry without ultra-high vacuum†","authors":"Emeline Hanozin, Conner C. Harper, Jacob S. Jordan, Zachary M. Miller and Evan R. Williams","doi":"10.1039/D5AN00019J","DOIUrl":null,"url":null,"abstract":"<p >Charge detection mass spectrometry (CDMS) measurements of individual ions using either Orbitrap or electrostatic ion trap-based instruments have heretofore been performed under ultra-high vacuum conditions (10<small><sup>−9</sup></small> Torr or lower). The rationale for this expensive and often cumbersome requirement is that these measurements need to be performed in an environment where collisions with background gas do not adversely affect the measurements. Here, the use of an electrostatic trap that accepts a broad range of ion energies and a dynamic ion signal analysis method enables accurate CDMS mass measurements at pressures as high as 1 × 10<small><sup>−6</sup></small> Torr, multiple orders of magnitude higher than previously demonstrated. Consistent, accurate masses were obtained for pentameric antibody complexes (∼800 kDa), adeno-associated viruses (∼4.8 MDa), and both ∼50 and ∼100 nm diameter polystyrene nanoparticles (∼35 MDa and ∼330 MDa, respectively) at pressures ranging from 1 × 10<small><sup>−8</sup></small> Torr to 1 × 10<small><sup>−6</sup></small> Torr. The relationships between ion mass, trap pressure, ion lifetimes, individual ion energies and survival rates were investigated over a 1 s trapping period. Larger ions are more robust to higher pressures. While the trapping lifetimes of smaller ions decrease with increasing pressure, enough survive long enough for accurate mass measurements to be made. Some ions are lost because collisional dampening decreases their energies below the minimum stability threshold of the trap, but others with sufficient energy are still lost due to collision-induced scattering that moves the ions too far from the central trapping axis.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":" 8","pages":" 1605-1616"},"PeriodicalIF":3.6000,"publicationDate":"2025-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/an/d5an00019j","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Charge detection mass spectrometry (CDMS) measurements of individual ions using either Orbitrap or electrostatic ion trap-based instruments have heretofore been performed under ultra-high vacuum conditions (10−9 Torr or lower). The rationale for this expensive and often cumbersome requirement is that these measurements need to be performed in an environment where collisions with background gas do not adversely affect the measurements. Here, the use of an electrostatic trap that accepts a broad range of ion energies and a dynamic ion signal analysis method enables accurate CDMS mass measurements at pressures as high as 1 × 10−6 Torr, multiple orders of magnitude higher than previously demonstrated. Consistent, accurate masses were obtained for pentameric antibody complexes (∼800 kDa), adeno-associated viruses (∼4.8 MDa), and both ∼50 and ∼100 nm diameter polystyrene nanoparticles (∼35 MDa and ∼330 MDa, respectively) at pressures ranging from 1 × 10−8 Torr to 1 × 10−6 Torr. The relationships between ion mass, trap pressure, ion lifetimes, individual ion energies and survival rates were investigated over a 1 s trapping period. Larger ions are more robust to higher pressures. While the trapping lifetimes of smaller ions decrease with increasing pressure, enough survive long enough for accurate mass measurements to be made. Some ions are lost because collisional dampening decreases their energies below the minimum stability threshold of the trap, but others with sufficient energy are still lost due to collision-induced scattering that moves the ions too far from the central trapping axis.

Abstract Image

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信