Estimation of Intracranial Pressure in Patients with Traumatic Brain Injury by Optic Nerve Sheath Diameter Ultrasonography.

IF 1.7 4区 医学 Q3 CLINICAL NEUROLOGY
Mohamed Ali Youssef ElBheery, Abdelmaksod Mohammed Mousa, Mohamed Amr Eltayab, AbdElRhman Enayet
{"title":"Estimation of Intracranial Pressure in Patients with Traumatic Brain Injury by Optic Nerve Sheath Diameter Ultrasonography.","authors":"Mohamed Ali Youssef ElBheery, Abdelmaksod Mohammed Mousa, Mohamed Amr Eltayab, AbdElRhman Enayet","doi":"10.1227/ons.0000000000001549","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Intracranial pressure (ICP) is the cornerstone for physiological neuromonitoring after traumatic brain injuries (TBIs). Optic nerve sheath diameter (ONSD) ultrasonography serves as a noninvasive alternative for the gold standard invasive ICP monitoring devices. We aimed to evaluate the use of ultrasound ONSD as a tool for early detection and follow-up of increasing ICP in TBI in a low socioeconomic developing country where invasive devices are not always available.</p><p><strong>Methods: </strong>A prospective observational study was conducted on 50 polytrauma patients with TBI, who were older than 18 years with and Glasgow Coma Scale above 5, and a computed tomography (CT) brain in trauma survey showing signs of increasing ICP. All patients were recruited from the emergency department and intensive care unit at Cairo and October 6 University hospitals from January to May 2022. Clinical assessment, CT brain, and ONSD ultrasonography were performed on admission, after 12 hours, and after 48 hours. ONSD 5.0 mm was correlated with raised ICP in this study.</p><p><strong>Results: </strong>ONSD ranged from 4.6 to 7.1 mm with mean ± SD of 5.93 ± 0.55 on admission. On the second follow-up, the range regressed to 4.5 to 6.0 mm with mean ± SD of 4.8 ± 0.48, suggesting a decrease in the measurements of ONSD after receiving treatment either medical or surgical. The correlation between the measurement of ONSD and the CT findings indicating raised or decreased ICP was found in 94%, 82%, and 90% of patients on admission, first follow-up, and second follow-up, respectively. The specificity of ONSD measurement was 100% on admission and second follow-up, and its accuracy was 94% and 90 % for both occasions, respectively.</p><p><strong>Conclusion: </strong>Bedside ONSD measurements are highly correlated with CT brain findings and dynamic changes in ICP in response to head trauma management protocols. Hence, ultrasonic ONSD can replace invasive monitoring in following the ICP of patients with TBI.</p>","PeriodicalId":54254,"journal":{"name":"Operative Neurosurgery","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1227/ons.0000000000001549","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: Intracranial pressure (ICP) is the cornerstone for physiological neuromonitoring after traumatic brain injuries (TBIs). Optic nerve sheath diameter (ONSD) ultrasonography serves as a noninvasive alternative for the gold standard invasive ICP monitoring devices. We aimed to evaluate the use of ultrasound ONSD as a tool for early detection and follow-up of increasing ICP in TBI in a low socioeconomic developing country where invasive devices are not always available.

Methods: A prospective observational study was conducted on 50 polytrauma patients with TBI, who were older than 18 years with and Glasgow Coma Scale above 5, and a computed tomography (CT) brain in trauma survey showing signs of increasing ICP. All patients were recruited from the emergency department and intensive care unit at Cairo and October 6 University hospitals from January to May 2022. Clinical assessment, CT brain, and ONSD ultrasonography were performed on admission, after 12 hours, and after 48 hours. ONSD 5.0 mm was correlated with raised ICP in this study.

Results: ONSD ranged from 4.6 to 7.1 mm with mean ± SD of 5.93 ± 0.55 on admission. On the second follow-up, the range regressed to 4.5 to 6.0 mm with mean ± SD of 4.8 ± 0.48, suggesting a decrease in the measurements of ONSD after receiving treatment either medical or surgical. The correlation between the measurement of ONSD and the CT findings indicating raised or decreased ICP was found in 94%, 82%, and 90% of patients on admission, first follow-up, and second follow-up, respectively. The specificity of ONSD measurement was 100% on admission and second follow-up, and its accuracy was 94% and 90 % for both occasions, respectively.

Conclusion: Bedside ONSD measurements are highly correlated with CT brain findings and dynamic changes in ICP in response to head trauma management protocols. Hence, ultrasonic ONSD can replace invasive monitoring in following the ICP of patients with TBI.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Operative Neurosurgery
Operative Neurosurgery Medicine-Neurology (clinical)
CiteScore
3.10
自引率
13.00%
发文量
530
期刊介绍: Operative Neurosurgery is a bi-monthly, unique publication focusing exclusively on surgical technique and devices, providing practical, skill-enhancing guidance to its readers. Complementing the clinical and research studies published in Neurosurgery, Operative Neurosurgery brings the reader technical material that highlights operative procedures, anatomy, instrumentation, devices, and technology. Operative Neurosurgery is the practical resource for cutting-edge material that brings the surgeon the most up to date literature on operative practice and technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信