LC-ESI-MS/MS method for the accurate quantification of eight nitrosamines in pharmaceutical products.

IF 1.1 4区 化学 Q4 PHYSICS, ATOMIC, MOLECULAR & CHEMICAL
Ibrahim Danis, Durisehvar Ozer Unal
{"title":"LC-ESI-MS/MS method for the accurate quantification of eight nitrosamines in pharmaceutical products.","authors":"Ibrahim Danis, Durisehvar Ozer Unal","doi":"10.1177/14690667251328823","DOIUrl":null,"url":null,"abstract":"<p><p>In 2018, the Food and Drug Administration and the European Medicines Agency identified nitrosamine impurities in certain drugs, prompting detailed investigations by international regulatory authorities. According to ICH M7 (R1) guidelines, nitrosamines are classified as Class 1 substances, the most hazardous category, based on their carcinogenic and mutagenic properties. They are also recognized as probable human carcinogens by the International Agency for Research on Cancer. Since nitrosamine-induced DNA damage poses significant health risks, identifying potential nitrosamines in pharmaceutical products is crucial. In this study, a simple and efficient extraction method was designed to minimize matrix effects. These effects were evaluated using calibration curves prepared for each drug product in their respective matrices. The developed method was performed using an Agilent 1260 series HPLC system and an Agilent 6460 triple quadrupole tandem mass spectrometer. An Inertsil ODS-3 C18 (5 µm, 4.6 × 150 mm) column was employed for chromatographic separation. A triple quadrupole mass detector with electrospray ionization was used for detection, and multiple reaction monitoring was employed for quantification. The correlation coefficients (r²) were at least 0.999 for all eight nitrosamines. Limit of detection and limit of quantification values were determined as 0.05-0.8 ng/mL and 0.1-2.0 ng/mL, respectively. Validation results demonstrated satisfactory selectivity, accuracy, precision, and stability. The results demonstrated that the developed method is capable of reliably detecting potential nitrosamines present in pharmaceutical products at trace levels. This method contributes significantly to pharmaceutical safety and can serve as a valuable tool for future analyses.</p>","PeriodicalId":12007,"journal":{"name":"European Journal of Mass Spectrometry","volume":" ","pages":"14690667251328823"},"PeriodicalIF":1.1000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/14690667251328823","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In 2018, the Food and Drug Administration and the European Medicines Agency identified nitrosamine impurities in certain drugs, prompting detailed investigations by international regulatory authorities. According to ICH M7 (R1) guidelines, nitrosamines are classified as Class 1 substances, the most hazardous category, based on their carcinogenic and mutagenic properties. They are also recognized as probable human carcinogens by the International Agency for Research on Cancer. Since nitrosamine-induced DNA damage poses significant health risks, identifying potential nitrosamines in pharmaceutical products is crucial. In this study, a simple and efficient extraction method was designed to minimize matrix effects. These effects were evaluated using calibration curves prepared for each drug product in their respective matrices. The developed method was performed using an Agilent 1260 series HPLC system and an Agilent 6460 triple quadrupole tandem mass spectrometer. An Inertsil ODS-3 C18 (5 µm, 4.6 × 150 mm) column was employed for chromatographic separation. A triple quadrupole mass detector with electrospray ionization was used for detection, and multiple reaction monitoring was employed for quantification. The correlation coefficients (r²) were at least 0.999 for all eight nitrosamines. Limit of detection and limit of quantification values were determined as 0.05-0.8 ng/mL and 0.1-2.0 ng/mL, respectively. Validation results demonstrated satisfactory selectivity, accuracy, precision, and stability. The results demonstrated that the developed method is capable of reliably detecting potential nitrosamines present in pharmaceutical products at trace levels. This method contributes significantly to pharmaceutical safety and can serve as a valuable tool for future analyses.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.40
自引率
7.70%
发文量
16
审稿时长
>12 weeks
期刊介绍: JMS - European Journal of Mass Spectrometry, is a peer-reviewed journal, devoted to the publication of innovative research in mass spectrometry. Articles in the journal come from proteomics, metabolomics, petroleomics and other areas developing under the umbrella of the “omic revolution”.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信