Enhancing antibiotic detection via an aptasensor: the case of ciprofloxacin

IF 4.3 2区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
Eva Hobeika, Joseph Saab, Souheil Hallit, Isaac-Aaron Morales Frias, Nicole Jaffrezic-Renault, Abdelhamid Errachid
{"title":"Enhancing antibiotic detection via an aptasensor: the case of ciprofloxacin","authors":"Eva Hobeika,&nbsp;Joseph Saab,&nbsp;Souheil Hallit,&nbsp;Isaac-Aaron Morales Frias,&nbsp;Nicole Jaffrezic-Renault,&nbsp;Abdelhamid Errachid","doi":"10.1186/s13065-025-01425-1","DOIUrl":null,"url":null,"abstract":"<div><p>The need for fast, efficient, and cost-effective test systems for antibiotics is surging, to control resistant bacterial strains. Electrochemical biosensors offer a good alternative to routine laboratory-bound analytical methods. These biosensors are portable, suitable for in-field analysis and biocompatible for detection of small biomolecules. The aim of this work is the ciprofloxacin active pharmaceutical ingredient since resistance of bacteria to this antibiotic is reportedly increasing worldwide, especially in Lebanon where hospitalization bills are no longer affordable. So, the target is ciprofloxacin detection, a fluoroquinolone antibiotic, on screen-printed electrodes. Following diazonium salt, also known as carboxymethylaniline (CMA) deposition, a ciprofloxacin oligonucleotide was incubated on the electrode. This aptamer acts as an anchor for the ciprofloxacin molecule, allowing the latter’s attachment to the electrode and its quantification. Electrochemical characterization, through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) allowed for deposition of molecules on electrodes and confirmation that an electrochemical change took place. Scanning Electron Microscope images are used to confirm conformational changes on the surface of electrodes. Impedance results reported a limit of detection of LOD = 3 nM, a dynamic range from 10 nM to 100 µM, and reproducibility of results between two aptasensors to be 10%. Moreover, impedimetric sensor specificity evaluation was through the effect of interfering compounds tobramycin, ofloxacin, norfloxacin and ceftriaxone, on the aptasensor’s response. Based on available literature, this LOD level reached allows for the detection of ciprofloxacin via a portable potentiostat in environmental (wastewater, food), biological (urine, saliva) and pharmaceutical samples (efficient market withdrawal of counterfeit medications from pharmaceutical storage facilities).</p></div>","PeriodicalId":496,"journal":{"name":"BMC Chemistry","volume":"19 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://bmcchem.biomedcentral.com/counter/pdf/10.1186/s13065-025-01425-1","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1186/s13065-025-01425-1","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The need for fast, efficient, and cost-effective test systems for antibiotics is surging, to control resistant bacterial strains. Electrochemical biosensors offer a good alternative to routine laboratory-bound analytical methods. These biosensors are portable, suitable for in-field analysis and biocompatible for detection of small biomolecules. The aim of this work is the ciprofloxacin active pharmaceutical ingredient since resistance of bacteria to this antibiotic is reportedly increasing worldwide, especially in Lebanon where hospitalization bills are no longer affordable. So, the target is ciprofloxacin detection, a fluoroquinolone antibiotic, on screen-printed electrodes. Following diazonium salt, also known as carboxymethylaniline (CMA) deposition, a ciprofloxacin oligonucleotide was incubated on the electrode. This aptamer acts as an anchor for the ciprofloxacin molecule, allowing the latter’s attachment to the electrode and its quantification. Electrochemical characterization, through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) allowed for deposition of molecules on electrodes and confirmation that an electrochemical change took place. Scanning Electron Microscope images are used to confirm conformational changes on the surface of electrodes. Impedance results reported a limit of detection of LOD = 3 nM, a dynamic range from 10 nM to 100 µM, and reproducibility of results between two aptasensors to be 10%. Moreover, impedimetric sensor specificity evaluation was through the effect of interfering compounds tobramycin, ofloxacin, norfloxacin and ceftriaxone, on the aptasensor’s response. Based on available literature, this LOD level reached allows for the detection of ciprofloxacin via a portable potentiostat in environmental (wastewater, food), biological (urine, saliva) and pharmaceutical samples (efficient market withdrawal of counterfeit medications from pharmaceutical storage facilities).

为了控制抗药性细菌菌株,对快速、高效、经济的抗生素检测系统的需求急剧增加。电化学生物传感器为常规实验室分析方法提供了一个很好的替代方案。这些生物传感器便于携带,适合现场分析,并具有生物兼容性,可用于小生物分子的检测。这项工作的目标是环丙沙星的活性药物成分,因为据报道,细菌对这种抗生素的耐药性正在全球范围内不断增加,特别是在黎巴嫩,那里的住院费用已不再负担得起。因此,目标是在丝网印刷电极上检测环丙沙星(一种氟喹诺酮类抗生素)。在重氮盐(也称为羧甲基苯胺(CMA))沉积后,在电极上孵育环丙沙星寡核苷酸。这种适配体可作为环丙沙星分子的锚,使后者附着在电极上并进行定量。通过循环伏安法(CV)和电化学阻抗谱法(EIS)进行电化学表征,可以在电极上沉积分子,并确认发生了电化学变化。扫描电子显微镜图像用于确认电极表面的构象变化。阻抗结果表明,检测限为 LOD = 3 nM,动态范围为 10 nM 至 100 µM,两个适体传感器之间的结果重现性为 10%。此外,还通过干扰化合物妥布霉素、氧氟沙星、诺氟沙星和头孢曲松对准传感器响应的影响,对阻抗传感器的特异性进行了评估。根据现有文献,所达到的 LOD 水平允许通过便携式电位仪检测环境(废水、食品)、生物(尿液、唾液)和药品样品(从药品储存设施中有效地提取市场上的假药)中的环丙沙星。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Chemistry
BMC Chemistry Chemistry-General Chemistry
CiteScore
5.30
自引率
2.20%
发文量
92
审稿时长
27 weeks
期刊介绍: BMC Chemistry, formerly known as Chemistry Central Journal, is now part of the BMC series journals family. Chemistry Central Journal has served the chemistry community as a trusted open access resource for more than 10 years – and we are delighted to announce the next step on its journey. In January 2019 the journal has been renamed BMC Chemistry and now strengthens the BMC series footprint in the physical sciences by publishing quality articles and by pushing the boundaries of open chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信