Eco-friendly RP-HPLC method for simultaneous determination of water-soluble and fat-soluble vitamins in nano-formula and pharmaceutical dosage forms

IF 4.3 2区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
Safaa Hussein Salah El-Din, Amr M. Mahmoud, Amany Morsi
{"title":"Eco-friendly RP-HPLC method for simultaneous determination of water-soluble and fat-soluble vitamins in nano-formula and pharmaceutical dosage forms","authors":"Safaa Hussein Salah El-Din,&nbsp;Amr M. Mahmoud,&nbsp;Amany Morsi","doi":"10.1186/s13065-025-01441-1","DOIUrl":null,"url":null,"abstract":"<div><p>A green method for simultaneous determination of water soluble vitamin (vitamin C) and fat soluble vitamin (vitamin A) was developed using reversed phase high performance liquid chromatography technique. The method succeed to separate the water-soluble and fat-soluble vitamins by isocratic elution using Agilent Zorbax octylsilane column (250 × 4.6 mm, 5 μm) in a short single run. The proposed mobile phase consisted of buffer (10 mM potassium dihydrogen phosphate and 3 mM hexane sulfonic acid sodium salt), pH adjusted to 2.5 using orthophosphoric acid and methanol in a ratio (8:92 v/v) with flow rate 1.0 mL.min<sup>− 1</sup> and UV detection 328 nm for vitamin A and 243 nm for vitamin C in concentration range (0.5–30 IU.mL<sup>− 1</sup>) and (1–60 µg.mL<sup>− 1</sup>), respectively. Accuracy results were 99.49% ± 1.58 for vitamin C and 100.26% ± 1.86 for vitamin A, limit of detection (L.O.D) of vitamin C is 0.3 µg.mL<sup>− 1</sup> while for vitamin A is 0.15 IU.mL<sup>− 1</sup> and limit of quantification (L.O.Q) of vitamin C is 1.0 µg.mL<sup>− 1</sup> while for vitamin A is 0.5 IU.mL<sup>− 1</sup>. Analytical eco scale and green analytical procedure index showed that our proposed method is greener than the reported method. The proposed method validation was performed according to ICH guidelines and the method was applied successfully for determination of vitamin A and vitamin C simultaneously in cosmetic nano-formulation, pharmaceutical dosage form and in pure forms.</p></div>","PeriodicalId":496,"journal":{"name":"BMC Chemistry","volume":"19 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://bmcchem.biomedcentral.com/counter/pdf/10.1186/s13065-025-01441-1","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1186/s13065-025-01441-1","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

A green method for simultaneous determination of water soluble vitamin (vitamin C) and fat soluble vitamin (vitamin A) was developed using reversed phase high performance liquid chromatography technique. The method succeed to separate the water-soluble and fat-soluble vitamins by isocratic elution using Agilent Zorbax octylsilane column (250 × 4.6 mm, 5 μm) in a short single run. The proposed mobile phase consisted of buffer (10 mM potassium dihydrogen phosphate and 3 mM hexane sulfonic acid sodium salt), pH adjusted to 2.5 using orthophosphoric acid and methanol in a ratio (8:92 v/v) with flow rate 1.0 mL.min− 1 and UV detection 328 nm for vitamin A and 243 nm for vitamin C in concentration range (0.5–30 IU.mL− 1) and (1–60 µg.mL− 1), respectively. Accuracy results were 99.49% ± 1.58 for vitamin C and 100.26% ± 1.86 for vitamin A, limit of detection (L.O.D) of vitamin C is 0.3 µg.mL− 1 while for vitamin A is 0.15 IU.mL− 1 and limit of quantification (L.O.Q) of vitamin C is 1.0 µg.mL− 1 while for vitamin A is 0.5 IU.mL− 1. Analytical eco scale and green analytical procedure index showed that our proposed method is greener than the reported method. The proposed method validation was performed according to ICH guidelines and the method was applied successfully for determination of vitamin A and vitamin C simultaneously in cosmetic nano-formulation, pharmaceutical dosage form and in pure forms.

同时测定纳米配方和药物剂型中水溶性和脂溶性维生素的环保型 RP-HPLC 方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Chemistry
BMC Chemistry Chemistry-General Chemistry
CiteScore
5.30
自引率
2.20%
发文量
92
审稿时长
27 weeks
期刊介绍: BMC Chemistry, formerly known as Chemistry Central Journal, is now part of the BMC series journals family. Chemistry Central Journal has served the chemistry community as a trusted open access resource for more than 10 years – and we are delighted to announce the next step on its journey. In January 2019 the journal has been renamed BMC Chemistry and now strengthens the BMC series footprint in the physical sciences by publishing quality articles and by pushing the boundaries of open chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信