New compartment model for hepatic blood flow quantification in humans from 15O-water PET images

IF 8.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Oona Rainio, Juhani Knuuti, Riku Klén
{"title":"New compartment model for hepatic blood flow quantification in humans from 15O-water PET images","authors":"Oona Rainio, Juhani Knuuti, Riku Klén","doi":"10.1007/s00259-025-07210-5","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Background</h3><p>Different compartment models are commonly used to derive crucial information about blood flow, metabolism, and oxygenation from the results of a dynamic positron emission tomography (PET) scan. However, compared to blood flow in many other organs of interest, the hepatic blood flow (HBF) quantification is challenging due to the dual blood supply of liver from both the hepatic artery and the portal vein (PV). Here, we introduce a new model that can be used to estimate the HBF in combination with an automatic volume of interest selection method.</p><h3 data-test=\"abstract-sub-heading\">Materials and methods</h3><p>By using the <span>\\(^{15}\\)</span>O-water PET data of 57 patients, we extract the mean time-activity curves (TACs) from aorta, hepatic PV, liver, and spleen with help of an automated computer tomography-based segmentation tool and systematically fit our new compartment model and three earlier compartment models from literature to the TACs. After this, we compare the model performance with mean relative error (MRE), mean squared error, and Akaike’s information criteria with one-sided Wilcoxon signed-rank tests. After determining the best model, we study possible HBF differences caused by age, sex, and weight with Mann-Whitney U test and Pearson’s correlations coefficient.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>We obtained the mean arterial HBF of 0.299±0.168 mL/min/mL, the mean portal HBF of 0.930±0.520 mL/min/mL, and the total HBF of 1.229±0.612 mL/min/mL with our new model. Based on earlier research, both these estimates and also the results of two earlier versions of the original dual-input model are realistic. Out of these three models, our proposed model performed the best in terms of MRE (p-values<span>\\(\\le \\)</span>0.001). According to our results, there are no significant sex- or age-based differences but there is moderate positive correlation between the arterial and portal HBFs and negative correlation between the total HBF and the weight of patients.</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>The HBF can effectively be estimated from <span>\\(^{15}\\)</span>O-water PET data with our new model in combination with robust segmentation by TotalSegmentator. Due to the fact that potential underestimation of the PV concentration caused by the small size of this vessel might lead to overestimation of the HBF, more research would be beneficial to validate these methods further. Our results suggests that there is a negative trend between the HBF and the weight, though this might be related to the underlying conditions of the patients.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":"88 1","pages":""},"PeriodicalIF":8.6000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-025-07210-5","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Different compartment models are commonly used to derive crucial information about blood flow, metabolism, and oxygenation from the results of a dynamic positron emission tomography (PET) scan. However, compared to blood flow in many other organs of interest, the hepatic blood flow (HBF) quantification is challenging due to the dual blood supply of liver from both the hepatic artery and the portal vein (PV). Here, we introduce a new model that can be used to estimate the HBF in combination with an automatic volume of interest selection method.

Materials and methods

By using the \(^{15}\)O-water PET data of 57 patients, we extract the mean time-activity curves (TACs) from aorta, hepatic PV, liver, and spleen with help of an automated computer tomography-based segmentation tool and systematically fit our new compartment model and three earlier compartment models from literature to the TACs. After this, we compare the model performance with mean relative error (MRE), mean squared error, and Akaike’s information criteria with one-sided Wilcoxon signed-rank tests. After determining the best model, we study possible HBF differences caused by age, sex, and weight with Mann-Whitney U test and Pearson’s correlations coefficient.

Results

We obtained the mean arterial HBF of 0.299±0.168 mL/min/mL, the mean portal HBF of 0.930±0.520 mL/min/mL, and the total HBF of 1.229±0.612 mL/min/mL with our new model. Based on earlier research, both these estimates and also the results of two earlier versions of the original dual-input model are realistic. Out of these three models, our proposed model performed the best in terms of MRE (p-values\(\le \)0.001). According to our results, there are no significant sex- or age-based differences but there is moderate positive correlation between the arterial and portal HBFs and negative correlation between the total HBF and the weight of patients.

Conclusion

The HBF can effectively be estimated from \(^{15}\)O-water PET data with our new model in combination with robust segmentation by TotalSegmentator. Due to the fact that potential underestimation of the PV concentration caused by the small size of this vessel might lead to overestimation of the HBF, more research would be beneficial to validate these methods further. Our results suggests that there is a negative trend between the HBF and the weight, though this might be related to the underlying conditions of the patients.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信