Investigations on Directional Hearing With One-Sided Fitting of an Active Middle Ear Implant or Bone Conduction Hearing Implant.

IF 2.6 2区 医学 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Christoph Müller, Hannes Seidler, Janina Kuch, Anna Tsypina, Thomas Zahnert, Susen Lailach
{"title":"Investigations on Directional Hearing With One-Sided Fitting of an Active Middle Ear Implant or Bone Conduction Hearing Implant.","authors":"Christoph Müller, Hannes Seidler, Janina Kuch, Anna Tsypina, Thomas Zahnert, Susen Lailach","doi":"10.1097/AUD.0000000000001650","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In patients with conductive or combined unilateral hearing loss, implantable hearing systems can be a treatment option. Due to the overlapping indications of hearing implants, a systematic evaluation of audiologic differences in terms of speech intelligibility and binaural hearing abilities is necessary. Because of the unilateral cochlear stimulation in patients implanted with an active middle ear implant, we expect superior binaural hearing performance compared with patients implanted with a bone-conducting implant that causes bilateral cochlear stimulation. This study focuses especially on comparing directional hearing abilities between the aforementioned groups of implantable hearing aid users.</p><p><strong>Methods: </strong>In 13 patients unilaterally fitted with Vibrant Soundbridge (VSB) and 8 patients fitted with Bonebridge (BB) (both implants manufactured by MED-EL, Austria) (implantation at least 6 months ago, contralateral ear with at most mild hearing loss [pure tone average across 4 frequencies <30 dB]), sound localization ability, speech intelligibility (Freiburger monosyllabic word test and Oldenburgsentencetest), audiometric threshold-based measurements and patient-reported outcome measures (International Outcome Inventory for Hearing Aids and Speech, Spatial and Qualities of Hearing Scale 12) have been examined.</p><p><strong>Results: </strong>The groups did not differ significantly (p > 0.05) in terms of patient age (VSB: 44.6 ± 14.4 years [SD]; BB: 44.5 ± 17.3 years), pure tone average across 4 frequencies of bone conduction (VSB: 26.4 ± 6.9 dB; BB: 23.3 ± 6.7 dB), speech intelligibility (VSB: 80.0% ± 16.7%; BB: 69.4% ± 13.2% [Freiburger]) and Oldenburgsentencetest (VSB -8.9 ± 2.6 dB; BB: -7.2 ± 4.4 dB). Implantation was 4.2 ± 2.7 years (VSB) and 7.5 ± 3.5 years (BB) (p < 0.05). Sound tended to be localized more frequently (56% ± 16%) within the reference range in the VSB group than in the BB group (49% ± 12.9%) (p > 0.05). The VSB group tended to show a smaller lateral deviation of sound detection from the actual sound presentation direction, especially with frontal sound presentation, compared with the BB group. Lateral sound presentations above 60° were increasingly perceived in the direction contralateral to the sound source in both groups (p > 0.05). Subjective hearing disabilities were scored significantly lower in the VSB group compared with the BB group.</p><p><strong>Conclusion: </strong>When comparing the sound localization ability between BB and VSB users, the study displayed a trend toward better results with the VSB. Further measurement data of patient cohorts with larger group sizes have to be collected for a final judgment on the clinical significance of these differences.</p>","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/AUD.0000000000001650","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In patients with conductive or combined unilateral hearing loss, implantable hearing systems can be a treatment option. Due to the overlapping indications of hearing implants, a systematic evaluation of audiologic differences in terms of speech intelligibility and binaural hearing abilities is necessary. Because of the unilateral cochlear stimulation in patients implanted with an active middle ear implant, we expect superior binaural hearing performance compared with patients implanted with a bone-conducting implant that causes bilateral cochlear stimulation. This study focuses especially on comparing directional hearing abilities between the aforementioned groups of implantable hearing aid users.

Methods: In 13 patients unilaterally fitted with Vibrant Soundbridge (VSB) and 8 patients fitted with Bonebridge (BB) (both implants manufactured by MED-EL, Austria) (implantation at least 6 months ago, contralateral ear with at most mild hearing loss [pure tone average across 4 frequencies <30 dB]), sound localization ability, speech intelligibility (Freiburger monosyllabic word test and Oldenburgsentencetest), audiometric threshold-based measurements and patient-reported outcome measures (International Outcome Inventory for Hearing Aids and Speech, Spatial and Qualities of Hearing Scale 12) have been examined.

Results: The groups did not differ significantly (p > 0.05) in terms of patient age (VSB: 44.6 ± 14.4 years [SD]; BB: 44.5 ± 17.3 years), pure tone average across 4 frequencies of bone conduction (VSB: 26.4 ± 6.9 dB; BB: 23.3 ± 6.7 dB), speech intelligibility (VSB: 80.0% ± 16.7%; BB: 69.4% ± 13.2% [Freiburger]) and Oldenburgsentencetest (VSB -8.9 ± 2.6 dB; BB: -7.2 ± 4.4 dB). Implantation was 4.2 ± 2.7 years (VSB) and 7.5 ± 3.5 years (BB) (p < 0.05). Sound tended to be localized more frequently (56% ± 16%) within the reference range in the VSB group than in the BB group (49% ± 12.9%) (p > 0.05). The VSB group tended to show a smaller lateral deviation of sound detection from the actual sound presentation direction, especially with frontal sound presentation, compared with the BB group. Lateral sound presentations above 60° were increasingly perceived in the direction contralateral to the sound source in both groups (p > 0.05). Subjective hearing disabilities were scored significantly lower in the VSB group compared with the BB group.

Conclusion: When comparing the sound localization ability between BB and VSB users, the study displayed a trend toward better results with the VSB. Further measurement data of patient cohorts with larger group sizes have to be collected for a final judgment on the clinical significance of these differences.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Ear and Hearing
Ear and Hearing 医学-耳鼻喉科学
CiteScore
5.90
自引率
10.80%
发文量
207
审稿时长
6-12 weeks
期刊介绍: From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信