Needle sharpness is minimally affected by vaccine vial puncture.

IF 1.6 2区 农林科学 Q2 VETERINARY SCIENCES
Julia R Tawil, Emma C Vitello, Gina M Agostini-Walesch, John C Mitchell, Rachael E Kreisler
{"title":"Needle sharpness is minimally affected by vaccine vial puncture.","authors":"Julia R Tawil, Emma C Vitello, Gina M Agostini-Walesch, John C Mitchell, Rachael E Kreisler","doi":"10.2460/javma.25.01.0025","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To survey the commonality of needle-changing practices among veterinarians and measure whether 1 or 2 passages through a vaccine vial septum affects needle sharpness.</p><p><strong>Methods: </strong>An anonymous online survey of needle-changing behaviors by veterinary professionals was conducted from April to May 2023. Subsequently, a blinded randomized controlled bench trial assessed the impact of septum passage on needle sharpness between June and August 2023 at Midwestern University. Veterinary hypodermic needles of 3 brands and 4 gauges were tested after passing through a septum 0, 1, or 2 times. The primary outcome was the peak penetration force (PF) required to puncture standardized material. Secondary analysis involved visual examination of needles with the use of an optical 3-D surface roughness measurement instrument.</p><p><strong>Results: </strong>Of 482 survey respondents, 76% routinely changed needles due to concerns about dulling. Experimental results showed a minor increase in PF after 1 (9%) and 2 (18%) septum passages. Needle gauge and brand impacted PF more than septum passage, with differences of 6% to 58% and 9% to 10%, respectively. Visual inspection revealed a 40% incidence of gross defects after 1 passage and 52% after 2 passages, with PF through the vial septum being the strongest damage predictor.</p><p><strong>Conclusions: </strong>While septum passage slightly increased the PF, brand and gauge had a more substantial impact.</p><p><strong>Clinical relevance: </strong>This study suggests that changing needles may not be necessary for maintaining sharpness if proper technique is used, potentially reducing the risk of needlestick injuries and medical waste.</p>","PeriodicalId":14658,"journal":{"name":"Javma-journal of The American Veterinary Medical Association","volume":" ","pages":"1-7"},"PeriodicalIF":1.6000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Javma-journal of The American Veterinary Medical Association","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2460/javma.25.01.0025","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To survey the commonality of needle-changing practices among veterinarians and measure whether 1 or 2 passages through a vaccine vial septum affects needle sharpness.

Methods: An anonymous online survey of needle-changing behaviors by veterinary professionals was conducted from April to May 2023. Subsequently, a blinded randomized controlled bench trial assessed the impact of septum passage on needle sharpness between June and August 2023 at Midwestern University. Veterinary hypodermic needles of 3 brands and 4 gauges were tested after passing through a septum 0, 1, or 2 times. The primary outcome was the peak penetration force (PF) required to puncture standardized material. Secondary analysis involved visual examination of needles with the use of an optical 3-D surface roughness measurement instrument.

Results: Of 482 survey respondents, 76% routinely changed needles due to concerns about dulling. Experimental results showed a minor increase in PF after 1 (9%) and 2 (18%) septum passages. Needle gauge and brand impacted PF more than septum passage, with differences of 6% to 58% and 9% to 10%, respectively. Visual inspection revealed a 40% incidence of gross defects after 1 passage and 52% after 2 passages, with PF through the vial septum being the strongest damage predictor.

Conclusions: While septum passage slightly increased the PF, brand and gauge had a more substantial impact.

Clinical relevance: This study suggests that changing needles may not be necessary for maintaining sharpness if proper technique is used, potentially reducing the risk of needlestick injuries and medical waste.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.60
自引率
15.80%
发文量
539
审稿时长
6-16 weeks
期刊介绍: Published twice monthly, this peer-reviewed, general scientific journal provides reports of clinical research, feature articles and regular columns of interest to veterinarians in private and public practice. The News and Classified Ad sections are posted online 10 days to two weeks before they are delivered in print.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信