Estimating the plasma volume by infusing albumin: a retrospective feasibility study.

IF 2.8 Q2 CRITICAL CARE MEDICINE
Robert G Hahn, Joachim H Zdolsek
{"title":"Estimating the plasma volume by infusing albumin: a retrospective feasibility study.","authors":"Robert G Hahn, Joachim H Zdolsek","doi":"10.1186/s40635-025-00743-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The combined changes in plasma albumin and blood hemoglobin can probably be used to estimate the plasma volume (PV) when albumin is infused. However, the optimal setup, timing of the blood sampling, and the importance of capillary leakage to the calculations are unclear.</p><p><strong>Methods: </strong>In this technical vignette, we estimated the PV using retrospective data on plasma albumin and blood hemoglobin obtained during intravenous infusion of 3 mL/kg of 20% albumin over 30 min in 41 volunteers and 45 patients. We used a manual and a kinetic correction for capillary leakage of albumin. The results were compared to the mean of two anthropometric equations derived via tracer methods.</p><p><strong>Results: </strong>The anthropometric PV was 3.00 ± 0.63 L (mean ± SD). The strongest linearity between the albumin-derived and anthropometric PV was obtained at the end, and 10 min after the end, of the 30-min infusions; the correlation coefficient was 0.75 over this time frame. The difference between the two measures (the prediction error) was 0.31 ± 0.56 L but the SD was only half as high for PVs< 2.5 L than for larger PVs. There was slightly stronger linearity and better accuracy, but no better precision, when data were corrected for capillary leakage.</p><p><strong>Conclusion: </strong>This study suggests how an evaluation of this method using isotopes can be conducted. Changes in plasma albumin and blood hemoglobin have the best chance to accurately indicate the PV at the end of, or 10 min after, a 30-min infusion of albumin. Subtraction of 0.3 L from the PV is sufficient to correct for capillary leakage of albumin.</p>","PeriodicalId":13750,"journal":{"name":"Intensive Care Medicine Experimental","volume":"13 1","pages":"35"},"PeriodicalIF":2.8000,"publicationDate":"2025-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11923349/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intensive Care Medicine Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40635-025-00743-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The combined changes in plasma albumin and blood hemoglobin can probably be used to estimate the plasma volume (PV) when albumin is infused. However, the optimal setup, timing of the blood sampling, and the importance of capillary leakage to the calculations are unclear.

Methods: In this technical vignette, we estimated the PV using retrospective data on plasma albumin and blood hemoglobin obtained during intravenous infusion of 3 mL/kg of 20% albumin over 30 min in 41 volunteers and 45 patients. We used a manual and a kinetic correction for capillary leakage of albumin. The results were compared to the mean of two anthropometric equations derived via tracer methods.

Results: The anthropometric PV was 3.00 ± 0.63 L (mean ± SD). The strongest linearity between the albumin-derived and anthropometric PV was obtained at the end, and 10 min after the end, of the 30-min infusions; the correlation coefficient was 0.75 over this time frame. The difference between the two measures (the prediction error) was 0.31 ± 0.56 L but the SD was only half as high for PVs< 2.5 L than for larger PVs. There was slightly stronger linearity and better accuracy, but no better precision, when data were corrected for capillary leakage.

Conclusion: This study suggests how an evaluation of this method using isotopes can be conducted. Changes in plasma albumin and blood hemoglobin have the best chance to accurately indicate the PV at the end of, or 10 min after, a 30-min infusion of albumin. Subtraction of 0.3 L from the PV is sufficient to correct for capillary leakage of albumin.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Intensive Care Medicine Experimental
Intensive Care Medicine Experimental CRITICAL CARE MEDICINE-
CiteScore
5.10
自引率
2.90%
发文量
48
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信