Selection of DNA Aptamers Against Parathyroid Hormone for Electrochemical Impedimetric Biosensor System Development.

IF 3.2 4区 生物学 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
Reza Didarian, Saharnaz Bargh, Almina Gülerman, Veli Cengiz Özalp, Özcan Erel, Nimet Yildirim-Tirgil
{"title":"Selection of DNA Aptamers Against Parathyroid Hormone for Electrochemical Impedimetric Biosensor System Development.","authors":"Reza Didarian, Saharnaz Bargh, Almina Gülerman, Veli Cengiz Özalp, Özcan Erel, Nimet Yildirim-Tirgil","doi":"10.1002/bab.2745","DOIUrl":null,"url":null,"abstract":"<p><p>This work presents the pioneering development of an aptamer-based electrochemical biosensor for real-time monitoring of parathyroid hormone (PTH) levels, with a focus on intraoperative assessment during parathyroid surgery. It introduces, for the first time, the selection and characterization of aptamers targeting distinct segments of the PTH peptide. The study demonstrates the feasibility and efficacy of the biosensing platform through a precisely designed experimental framework, including SELEX-based aptamer selection, aptamer-peptide interaction analysis, and biosensor fabrication. The SELEX process yields aptamers with notable binding affinities to different fragments of PTH, with the PTH (53-84) aptamer showing particularly sensitive binding to the hormone's C terminus, allowing for precise PTH analysis. Electrochemical characterization reveals significant changes in electrochemical impedance spectroscopy (EIS) signals upon exposure to varying PTH concentrations, highlighting the sensor's sensitivity and selectivity. The increase in charge transfer resistance (Rct) values with rising PTH concentrations underscores the biosensor's capability to detect PTH-induced structural changes, validating its potential for accurate measurement. The biosensor shows remarkable selectivity in the presence of common interferents in serum samples, ensuring precise PTH detection. Stability assessments over a 45-day storage period demonstrate the biosensor's robustness and long-term reliability, affirming its practical suitability. In summary, the developed aptamer-based biosensor represents a promising tool for sensitive and selective PTH detection, with potential applications in biomedical research and clinical diagnostics, particularly for intraoperative PTH analysis during parathyroidectomy. Continued research and optimization efforts hold promise for enhancing its performance and expanding its utility in diverse healthcare settings.</p>","PeriodicalId":9274,"journal":{"name":"Biotechnology and applied biochemistry","volume":" ","pages":"e2745"},"PeriodicalIF":3.2000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology and applied biochemistry","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/bab.2745","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This work presents the pioneering development of an aptamer-based electrochemical biosensor for real-time monitoring of parathyroid hormone (PTH) levels, with a focus on intraoperative assessment during parathyroid surgery. It introduces, for the first time, the selection and characterization of aptamers targeting distinct segments of the PTH peptide. The study demonstrates the feasibility and efficacy of the biosensing platform through a precisely designed experimental framework, including SELEX-based aptamer selection, aptamer-peptide interaction analysis, and biosensor fabrication. The SELEX process yields aptamers with notable binding affinities to different fragments of PTH, with the PTH (53-84) aptamer showing particularly sensitive binding to the hormone's C terminus, allowing for precise PTH analysis. Electrochemical characterization reveals significant changes in electrochemical impedance spectroscopy (EIS) signals upon exposure to varying PTH concentrations, highlighting the sensor's sensitivity and selectivity. The increase in charge transfer resistance (Rct) values with rising PTH concentrations underscores the biosensor's capability to detect PTH-induced structural changes, validating its potential for accurate measurement. The biosensor shows remarkable selectivity in the presence of common interferents in serum samples, ensuring precise PTH detection. Stability assessments over a 45-day storage period demonstrate the biosensor's robustness and long-term reliability, affirming its practical suitability. In summary, the developed aptamer-based biosensor represents a promising tool for sensitive and selective PTH detection, with potential applications in biomedical research and clinical diagnostics, particularly for intraoperative PTH analysis during parathyroidectomy. Continued research and optimization efforts hold promise for enhancing its performance and expanding its utility in diverse healthcare settings.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biotechnology and applied biochemistry
Biotechnology and applied biochemistry 工程技术-生化与分子生物学
CiteScore
6.00
自引率
7.10%
发文量
117
审稿时长
3 months
期刊介绍: Published since 1979, Biotechnology and Applied Biochemistry is dedicated to the rapid publication of high quality, significant research at the interface between life sciences and their technological exploitation. The Editors will consider papers for publication based on their novelty and impact as well as their contribution to the advancement of medical biotechnology and industrial biotechnology, covering cutting-edge research in synthetic biology, systems biology, metabolic engineering, bioengineering, biomaterials, biosensing, and nano-biotechnology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信