Usage of 150 mm Mueller - Hinton Agar for the EUCAST rapid antimicrobial susceptibility test (RAST) directly from positive blood culture bottles.

IF 1.3 4区 医学 Q4 IMMUNOLOGY
Acta microbiologica et immunologica Hungarica Pub Date : 2025-03-20 Print Date: 2025-03-27 DOI:10.1556/030.2025.02538
Serap Süzük Yıldız, Sevgi Şahin, Esra Tavukcu, İpek Mumcuoğlu, Can Hüseyin Hekimoğlu, Ayşe Semra Güreser, Tuba Dal
{"title":"Usage of 150 mm Mueller - Hinton Agar for the EUCAST rapid antimicrobial susceptibility test (RAST) directly from positive blood culture bottles.","authors":"Serap Süzük Yıldız, Sevgi Şahin, Esra Tavukcu, İpek Mumcuoğlu, Can Hüseyin Hekimoğlu, Ayşe Semra Güreser, Tuba Dal","doi":"10.1556/030.2025.02538","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we evaluated the performance of modified rapid antimicrobial susceptibility test (mRAST) with 150 mm Mueller Hinton Agar (MHA) plates which was earlier standardized for 90 mm MHA by EUCAST. Blood culture bottles spiked with ATCC quality control strains were prepared. For quality control Escherichia coli ATCC 25922, Pseudomonas aeruginosa ATCC 27853, Staphylococcus aureus ATCC 29213, and Enterococcus faecalis ATCC 29212 strains were used. By calculating and proportioning the surface areas of the plates comparing with 90 mm plates, 350 ± 50 µL undiluted blood culture samples were inoculated in 150 mm MHA, and 12 disks were placed. This process was repeated independently for three days and three times on each day for reproducibility. The mRAST test was performed on 50 samples with positive signals and gram-negative bacilli on Gram-stained samples (20 Klebsiella pneumoniae, 15 E. coli, 10 Acinetobacter baumannii, and five P. aeruginosa).Comparison of 90 mm MHA and 150 mm MHA showed that the categorical agreement of ATCC strains and 50 gram negative isolates was 100% and >95%, respectively, for all antibiotics. For K. pneumoniae, only 0.4 major error (ME) was detected at 4 h. For E. coli, 3.2, 1.6, and 1.5 ME were detected at 4, 8, and 20 h, respectively, whereas 1.6 very major error (VME) was detected at 4 h and 1.0 VME was detected at both 8, and 20 h, respectively. No errors were detected for P. aeruginosa or A. baumannii.These results indicated that 350 ± 50 µL of undiluted blood culture in 150 mm MHA was suitable for the mRAST test in vitro.</p>","PeriodicalId":7119,"journal":{"name":"Acta microbiologica et immunologica Hungarica","volume":" ","pages":"43-48"},"PeriodicalIF":1.3000,"publicationDate":"2025-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta microbiologica et immunologica Hungarica","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1556/030.2025.02538","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/27 0:00:00","PubModel":"Print","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we evaluated the performance of modified rapid antimicrobial susceptibility test (mRAST) with 150 mm Mueller Hinton Agar (MHA) plates which was earlier standardized for 90 mm MHA by EUCAST. Blood culture bottles spiked with ATCC quality control strains were prepared. For quality control Escherichia coli ATCC 25922, Pseudomonas aeruginosa ATCC 27853, Staphylococcus aureus ATCC 29213, and Enterococcus faecalis ATCC 29212 strains were used. By calculating and proportioning the surface areas of the plates comparing with 90 mm plates, 350 ± 50 µL undiluted blood culture samples were inoculated in 150 mm MHA, and 12 disks were placed. This process was repeated independently for three days and three times on each day for reproducibility. The mRAST test was performed on 50 samples with positive signals and gram-negative bacilli on Gram-stained samples (20 Klebsiella pneumoniae, 15 E. coli, 10 Acinetobacter baumannii, and five P. aeruginosa).Comparison of 90 mm MHA and 150 mm MHA showed that the categorical agreement of ATCC strains and 50 gram negative isolates was 100% and >95%, respectively, for all antibiotics. For K. pneumoniae, only 0.4 major error (ME) was detected at 4 h. For E. coli, 3.2, 1.6, and 1.5 ME were detected at 4, 8, and 20 h, respectively, whereas 1.6 very major error (VME) was detected at 4 h and 1.0 VME was detected at both 8, and 20 h, respectively. No errors were detected for P. aeruginosa or A. baumannii.These results indicated that 350 ± 50 µL of undiluted blood culture in 150 mm MHA was suitable for the mRAST test in vitro.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
13.30%
发文量
36
审稿时长
>12 weeks
期刊介绍: AMIH is devoted to the publication of research in all fields of medical microbiology (bacteriology, virology, parasitology, mycology); immunology of infectious diseases and study of the microbiome related to human diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信