Titanium micro-particles are commonly found in soft tissues surrounding dental implants.

IF 5.4 Q1 MEDICINE, RESEARCH & EXPERIMENTAL
Carlotta Dionigi, Gyula Nagy, Jan Derks, Yuki Ichioka, Cristiano Tomasi, Lena Larsson, Daniel Primetzhofer, Tord Berglundh
{"title":"Titanium micro-particles are commonly found in soft tissues surrounding dental implants.","authors":"Carlotta Dionigi, Gyula Nagy, Jan Derks, Yuki Ichioka, Cristiano Tomasi, Lena Larsson, Daniel Primetzhofer, Tord Berglundh","doi":"10.1038/s43856-025-00756-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Dental implants are one of the most frequently used medical devices for therapeutic purposes in dentistry. Peri-implantitis is a severe, microbial biofilm-associated condition, characterized by inflammation in peri-implant soft tissues and destruction of supporting bone. It has been suggested that metal particles originating from the implant may influence the local host response to microbial biofilms.</p><p><strong>Methods: </strong>Soft tissue biopsies were collected from implant sites with and without peri-implantitis in 21 patients. Micro Proton-induced X-ray Emission (µ-PIXE) analysis was used to localize, quantify and characterize titanium micro-particles within tissues. RNA sequencing was performed to evaluate potential associations between titanium micro-particles and gene expression profiles in peri-implantitis lesions.</p><p><strong>Results: </strong>Titanium micro-particles are consistent findings in soft tissues surrounding dental implants. Their occurrence varies across patients but not between sites with and without peri-implantitis within the same individual. Most particles reside in a 2-mm wide tissue portion close to the implant/tissue interface. The time in function of the implants does not influence the volumetric density of titanium micro-particles, while implant systems do. Fourteen differentially expressed genes are identified when comparing peri-implantitis samples with high and low densities of titanium micro-particles. The gene-set enrichment analysis reveals functions related to the regulation of the immune response and epithelial development.</p><p><strong>Conclusions: </strong>The present results indicate that titanium micro-particles are commonly found in tissues surrounding dental implants and are not associated with the occurrence of peri-implantitis.</p>","PeriodicalId":72646,"journal":{"name":"Communications medicine","volume":"5 1","pages":"78"},"PeriodicalIF":5.4000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Communications medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s43856-025-00756-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Dental implants are one of the most frequently used medical devices for therapeutic purposes in dentistry. Peri-implantitis is a severe, microbial biofilm-associated condition, characterized by inflammation in peri-implant soft tissues and destruction of supporting bone. It has been suggested that metal particles originating from the implant may influence the local host response to microbial biofilms.

Methods: Soft tissue biopsies were collected from implant sites with and without peri-implantitis in 21 patients. Micro Proton-induced X-ray Emission (µ-PIXE) analysis was used to localize, quantify and characterize titanium micro-particles within tissues. RNA sequencing was performed to evaluate potential associations between titanium micro-particles and gene expression profiles in peri-implantitis lesions.

Results: Titanium micro-particles are consistent findings in soft tissues surrounding dental implants. Their occurrence varies across patients but not between sites with and without peri-implantitis within the same individual. Most particles reside in a 2-mm wide tissue portion close to the implant/tissue interface. The time in function of the implants does not influence the volumetric density of titanium micro-particles, while implant systems do. Fourteen differentially expressed genes are identified when comparing peri-implantitis samples with high and low densities of titanium micro-particles. The gene-set enrichment analysis reveals functions related to the regulation of the immune response and epithelial development.

Conclusions: The present results indicate that titanium micro-particles are commonly found in tissues surrounding dental implants and are not associated with the occurrence of peri-implantitis.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信