Rating of perceived exertion versus heart rate for isometric exercise prescription: Reliability and agreement study.

IF 1.3 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL
Sao Paulo Medical Journal Pub Date : 2025-03-17 eCollection Date: 2025-01-01 DOI:10.1590/1516-3180.2024.0092.R1.29072024
Paulo Henrique de Melo, Anderson Cavalcante, Jessika Karla Tavares do Nascimento Faustino Silva, José Lucas Porto Aguiar, Jefferson Maxwell De Farias Silva, Theo Victor Alves Soares Rêgo, Raphael Mendes Ritti-Dias, Breno Quintella Farah
{"title":"Rating of perceived exertion versus heart rate for isometric exercise prescription: Reliability and agreement study.","authors":"Paulo Henrique de Melo, Anderson Cavalcante, Jessika Karla Tavares do Nascimento Faustino Silva, José Lucas Porto Aguiar, Jefferson Maxwell De Farias Silva, Theo Victor Alves Soares Rêgo, Raphael Mendes Ritti-Dias, Breno Quintella Farah","doi":"10.1590/1516-3180.2024.0092.R1.29072024","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Previous studies have shown that isometric exercise training reduces systolic blood pressure by approximately 8 mmHg and diastolic blood pressure by approximately 4 mmHg in both normotensive and hypertensive individuals. However, the prescription of isometric exercises can be based on the rating of perceived exertion (RPE) or heart rate (HR) obtained during the maximal incremental isometry test. The reliability and agreement of this test have not been assessed.</p><p><strong>Objectives: </strong>To analyze the reliability and agreement indicators of HR and RPE during isometric wall squat incremental tests.</p><p><strong>Design and setting: </strong>A reliability and agreement study was conducted at Universidade Federal de Pernambuco.</p><p><strong>Methods: </strong>Twenty-eight healthy subjects (54% men, 26 ± 5 years) performed two isometric wall squat incremental tests. The test began with a knee joint angle of 135° (knee and leg) progressively reduced by 10° at each stage. Each stage lasts 2 minutes or until voluntary exhaustion. The HR and RPE were obtained during the tests. Reliability and agreement were established using test-retest (paired t-test or Wilcoxon test), intraclass correlation coefficient (ICC), standard error of measurement (SEM), coefficient of variation (CV), and Bland-Altman plots.</p><p><strong>Results: </strong>The HR and RPE increased significantly during both tests. The HR and RPE at each stage were similar between the two test sessions (P > 0.05). Both HRmax (ICC: 0.695, P = 0.002, SEM = 8.1 bpm and CV = 5.8%) and RPEmax (ICC: 0.525, P = 0.036, SEM = 0.4 and CV = 3.6%) presented similar reliability indicators, and no statistically significant differences were obtained between the two test sessions (P > 0.05). The Bland-Altman plots indicated good agreement between HRmax and RPEmax.</p><p><strong>Conclusion: </strong>HR and RPE showed similar reliability and agreement during the isometric wall squat incremental test.</p>","PeriodicalId":49574,"journal":{"name":"Sao Paulo Medical Journal","volume":"143 2","pages":"e2024092"},"PeriodicalIF":1.3000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11922297/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sao Paulo Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1516-3180.2024.0092.R1.29072024","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Previous studies have shown that isometric exercise training reduces systolic blood pressure by approximately 8 mmHg and diastolic blood pressure by approximately 4 mmHg in both normotensive and hypertensive individuals. However, the prescription of isometric exercises can be based on the rating of perceived exertion (RPE) or heart rate (HR) obtained during the maximal incremental isometry test. The reliability and agreement of this test have not been assessed.

Objectives: To analyze the reliability and agreement indicators of HR and RPE during isometric wall squat incremental tests.

Design and setting: A reliability and agreement study was conducted at Universidade Federal de Pernambuco.

Methods: Twenty-eight healthy subjects (54% men, 26 ± 5 years) performed two isometric wall squat incremental tests. The test began with a knee joint angle of 135° (knee and leg) progressively reduced by 10° at each stage. Each stage lasts 2 minutes or until voluntary exhaustion. The HR and RPE were obtained during the tests. Reliability and agreement were established using test-retest (paired t-test or Wilcoxon test), intraclass correlation coefficient (ICC), standard error of measurement (SEM), coefficient of variation (CV), and Bland-Altman plots.

Results: The HR and RPE increased significantly during both tests. The HR and RPE at each stage were similar between the two test sessions (P > 0.05). Both HRmax (ICC: 0.695, P = 0.002, SEM = 8.1 bpm and CV = 5.8%) and RPEmax (ICC: 0.525, P = 0.036, SEM = 0.4 and CV = 3.6%) presented similar reliability indicators, and no statistically significant differences were obtained between the two test sessions (P > 0.05). The Bland-Altman plots indicated good agreement between HRmax and RPEmax.

Conclusion: HR and RPE showed similar reliability and agreement during the isometric wall squat incremental test.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Sao Paulo Medical Journal
Sao Paulo Medical Journal 医学-医学:内科
CiteScore
2.20
自引率
7.10%
发文量
210
审稿时长
6-12 weeks
期刊介绍: Published bimonthly by the Associação Paulista de Medicina, the journal accepts articles in the fields of clinical health science (internal medicine, gynecology and obstetrics, mental health, surgery, pediatrics and public health). Articles will be accepted in the form of original articles (clinical trials, cohort, case-control, prevalence, incidence, accuracy and cost-effectiveness studies and systematic reviews with or without meta-analysis), narrative reviews of the literature, case reports, short communications and letters to the editor. Papers with a commercial objective will not be accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信