{"title":"Comparison of different Raman spectrometer models in the quantification of blood serum analytes.","authors":"Hector Enrique Giana, Luisa Oliveira Souza, Landulfo Silveira","doi":"10.1007/s10103-025-04413-y","DOIUrl":null,"url":null,"abstract":"<p><p>The analytical performance of three commercial Raman spectrometers in determining the concentrations of analytes associated with diagnosing metabolic, cardiovascular, and renal disorders has been compared. Two portable and one benchtop spectrometers were tested to predict the serum concentrations of triglycerides (TRI), cholesterol (COL), high-density cholesterol, creatinine, urea, and glucose in 193 serum samples using partial least squares (PLS) regression and PLS discriminant analysis, the latter for classifying samples as either altered or within reference values. Strong correlations (r > 0.81) were obtained for TRI and COL analytes using the benchtop and one of the portable spectrometers, and the classification accuracy rates exceeded 90%, suggesting potential for use in clinical screening. Adding a glucose solution improved the correlation and the root mean square error for TRI and COL analytes; however, it did not enhance the correlation or error for the glucose analyte. Raman spectroscopy showed potential to support routine laboratory activities and may have applications in clinical screening.</p>","PeriodicalId":17978,"journal":{"name":"Lasers in Medical Science","volume":"40 1","pages":"143"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lasers in Medical Science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10103-025-04413-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The analytical performance of three commercial Raman spectrometers in determining the concentrations of analytes associated with diagnosing metabolic, cardiovascular, and renal disorders has been compared. Two portable and one benchtop spectrometers were tested to predict the serum concentrations of triglycerides (TRI), cholesterol (COL), high-density cholesterol, creatinine, urea, and glucose in 193 serum samples using partial least squares (PLS) regression and PLS discriminant analysis, the latter for classifying samples as either altered or within reference values. Strong correlations (r > 0.81) were obtained for TRI and COL analytes using the benchtop and one of the portable spectrometers, and the classification accuracy rates exceeded 90%, suggesting potential for use in clinical screening. Adding a glucose solution improved the correlation and the root mean square error for TRI and COL analytes; however, it did not enhance the correlation or error for the glucose analyte. Raman spectroscopy showed potential to support routine laboratory activities and may have applications in clinical screening.

不同拉曼光谱仪模型在血清分析物定量分析中的比较。
三个商业拉曼光谱仪的分析性能在确定与诊断代谢,心血管和肾脏疾病相关的分析物的浓度进行了比较。使用偏最小二乘法(PLS)回归和PLS判别分析对193份血清样本中的甘油三酯(TRI)、胆固醇(COL)、高密度胆固醇、肌酸酐、尿素和葡萄糖的血清浓度进行了预测,后者用于将样本分类为改变或在参考值范围内。使用台式光谱仪和一台便携式光谱仪,TRI和COL分析物获得了强相关性(r > 0.81),分类准确率超过90%,提示在临床筛查中有应用潜力。葡萄糖溶液的加入改善了TRI和COL分析物的相关性和均方根误差;然而,它并没有提高葡萄糖分析物的相关性或误差。拉曼光谱显示出支持常规实验室活动的潜力,并可能在临床筛查中应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Lasers in Medical Science
Lasers in Medical Science 医学-工程:生物医学
CiteScore
4.50
自引率
4.80%
发文量
192
审稿时长
3-8 weeks
期刊介绍: Lasers in Medical Science (LIMS) has established itself as the leading international journal in the rapidly expanding field of medical and dental applications of lasers and light. It provides a forum for the publication of papers on the technical, experimental, and clinical aspects of the use of medical lasers, including lasers in surgery, endoscopy, angioplasty, hyperthermia of tumors, and photodynamic therapy. In addition to medical laser applications, LIMS presents high-quality manuscripts on a wide range of dental topics, including aesthetic dentistry, endodontics, orthodontics, and prosthodontics. The journal publishes articles on the medical and dental applications of novel laser technologies, light delivery systems, sensors to monitor laser effects, basic laser-tissue interactions, and the modeling of laser-tissue interactions. Beyond laser applications, LIMS features articles relating to the use of non-laser light-tissue interactions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信