An ultra-fast UPLC-MS/MS approach for the quantification of baricitinib in the HLM matrix: greenness assessment with application to in vitro and in silico metabolic stability studies

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Mohamed W. Attwa, Ali S. Abdelhameed and Adnan A. Kadi
{"title":"An ultra-fast UPLC-MS/MS approach for the quantification of baricitinib in the HLM matrix: greenness assessment with application to in vitro and in silico metabolic stability studies","authors":"Mohamed W. Attwa, Ali S. Abdelhameed and Adnan A. Kadi","doi":"10.1039/D5AY00294J","DOIUrl":null,"url":null,"abstract":"<p >Baricitinib (Olumiant) is a Janus kinase inhibitor utilized for the management of COVID-19, rheumatoid arthritis, and alopecia areata. It received U.S. Food and Drug Administration approval on May 31, 2018. This work developed a sensitive, rapid, environmentally friendly, and reliable UPLC-MS/MS method for quantifying baricitinib in human liver microsomes, utilized to evaluate the <em>in vitro</em> metabolic stability of baricitinib in HLMs. The StarDrop software, with DEREK and P450 metabolic programs, was employed to detect the structural warnings related to BCB and assess the <em>in silico</em> metabolic lability. The validation of the UPLC-MS/MS approach conformed to U.S. Food and Drug Administration standards for bioanalytical approach validation. The present UPLC-MS/MS method exhibited a wide range of linearity (1.0–3000 ng mL<small><sup>−1</sup></small>) and optimum separation of analytes in an ultra-fast separation time (1 min) and was reproducible and accurate in the absence of human liver microsome matrix effects. Baricitinib and encorafenib (the internal standard) were examined employing an isocratic mobile phase technique on a reversed phase (SB C18) column. This study assessed the accuracy and precision of UPLC-MS/MS methodologies for intra- and inter-day evaluations, which ranged from −1.20% to 8.67% and 0.12% to 11.67%, respectively. The intrinsic clearance of baricitinib was quantified at 27.49 mL min<small><sup>−1</sup></small> kg<small><sup>−1</sup></small>, while the <em>in vitro</em> half-life was established at 29.50 minutes. <em>In silico</em> analysis proposes that slight structural alterations to the pyrrole ring (88%) and the pyrimidine ring (5%) in drug design may increase safety and metabolic stability related to baricitinib. The evaluation of <em>in silico</em> absorption, distribution, metabolism, excretion, and metabolic stability characteristics for baricitinib is crucial for advancing innovative drug discovery focused on enhancing metabolic stability.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 13","pages":" 2718-2732"},"PeriodicalIF":2.7000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d5ay00294j","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Baricitinib (Olumiant) is a Janus kinase inhibitor utilized for the management of COVID-19, rheumatoid arthritis, and alopecia areata. It received U.S. Food and Drug Administration approval on May 31, 2018. This work developed a sensitive, rapid, environmentally friendly, and reliable UPLC-MS/MS method for quantifying baricitinib in human liver microsomes, utilized to evaluate the in vitro metabolic stability of baricitinib in HLMs. The StarDrop software, with DEREK and P450 metabolic programs, was employed to detect the structural warnings related to BCB and assess the in silico metabolic lability. The validation of the UPLC-MS/MS approach conformed to U.S. Food and Drug Administration standards for bioanalytical approach validation. The present UPLC-MS/MS method exhibited a wide range of linearity (1.0–3000 ng mL−1) and optimum separation of analytes in an ultra-fast separation time (1 min) and was reproducible and accurate in the absence of human liver microsome matrix effects. Baricitinib and encorafenib (the internal standard) were examined employing an isocratic mobile phase technique on a reversed phase (SB C18) column. This study assessed the accuracy and precision of UPLC-MS/MS methodologies for intra- and inter-day evaluations, which ranged from −1.20% to 8.67% and 0.12% to 11.67%, respectively. The intrinsic clearance of baricitinib was quantified at 27.49 mL min−1 kg−1, while the in vitro half-life was established at 29.50 minutes. In silico analysis proposes that slight structural alterations to the pyrrole ring (88%) and the pyrimidine ring (5%) in drug design may increase safety and metabolic stability related to baricitinib. The evaluation of in silico absorption, distribution, metabolism, excretion, and metabolic stability characteristics for baricitinib is crucial for advancing innovative drug discovery focused on enhancing metabolic stability.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信