Selectivity Enhancement of Pesticide Biosensors via Polymer Coating

Angkana Phongphut;Seeroong Prichanont;Chanchana Thanachayanont;Hsin-Yi Tsai;Yu-Hsuan Lin;Keng-Ku Liu;Ruey-An Doong;Bralee Chayasombat
{"title":"Selectivity Enhancement of Pesticide Biosensors via Polymer Coating","authors":"Angkana Phongphut;Seeroong Prichanont;Chanchana Thanachayanont;Hsin-Yi Tsai;Yu-Hsuan Lin;Keng-Ku Liu;Ruey-An Doong;Bralee Chayasombat","doi":"10.1109/OJIM.2025.3545978","DOIUrl":null,"url":null,"abstract":"This work investigated the effects of polymer films [chitosan (CS), Nafion (NF), and polyvinyl alcohol (PVA)] on the performances of acetylcholinesterase (AChE) biosensors for the selectivity of pesticide types and their concentration levels using principal component analysis (PCA). AChE was immobilized on montmorillonite/gold nanoparticles (Mt/AuNPs). The surface charge of the polymer films significantly influenced sensor performance: NF and PVA films, with negative charges, enhanced the preconcentration of positively charged acetylthiocholine chloride (ATCh), resulting in increased electroactive surface area and current response. In contrast, the positively charged CS film impeded mass diffusion of ATCh, reducing electroactive surface area and current response. Sensor/PVA showed the lowest limit of detection (LOD) for chlorpyrifos and pirimiphos-methyl, while Sensor/CS showed the lowest LOD for carbaryl. The unique response from three different biosensors demonstrated the successful discrimination of the pesticide group and their concentration levels by PCA. The total contribution variance was 99.8%. PC1 suggested the concentration levels, while PC2 was explicitly realized for organophosphate pesticides (negative PC2) and carbaryl (positive PC2). These findings demonstrate that the simple application of polymer coatings, combined with PCA, can significantly improve the selectivity and storage stability of AChE-based biosensors.","PeriodicalId":100630,"journal":{"name":"IEEE Open Journal of Instrumentation and Measurement","volume":"4 ","pages":"1-12"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10908626","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Instrumentation and Measurement","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10908626/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work investigated the effects of polymer films [chitosan (CS), Nafion (NF), and polyvinyl alcohol (PVA)] on the performances of acetylcholinesterase (AChE) biosensors for the selectivity of pesticide types and their concentration levels using principal component analysis (PCA). AChE was immobilized on montmorillonite/gold nanoparticles (Mt/AuNPs). The surface charge of the polymer films significantly influenced sensor performance: NF and PVA films, with negative charges, enhanced the preconcentration of positively charged acetylthiocholine chloride (ATCh), resulting in increased electroactive surface area and current response. In contrast, the positively charged CS film impeded mass diffusion of ATCh, reducing electroactive surface area and current response. Sensor/PVA showed the lowest limit of detection (LOD) for chlorpyrifos and pirimiphos-methyl, while Sensor/CS showed the lowest LOD for carbaryl. The unique response from three different biosensors demonstrated the successful discrimination of the pesticide group and their concentration levels by PCA. The total contribution variance was 99.8%. PC1 suggested the concentration levels, while PC2 was explicitly realized for organophosphate pesticides (negative PC2) and carbaryl (positive PC2). These findings demonstrate that the simple application of polymer coatings, combined with PCA, can significantly improve the selectivity and storage stability of AChE-based biosensors.
通过聚合物涂层提高农药生物传感器的选择性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信