Numerical study on the flow and thermal characteristics of a two-phase closed thermosyphon filled with low surface tension working fluid under various wettability

IF 6.4 2区 工程技术 Q1 MECHANICS
Wandong Min, Wei Zhong, Lin Wang, Yanping Yuan, Xiaoling Cao
{"title":"Numerical study on the flow and thermal characteristics of a two-phase closed thermosyphon filled with low surface tension working fluid under various wettability","authors":"Wandong Min,&nbsp;Wei Zhong,&nbsp;Lin Wang,&nbsp;Yanping Yuan,&nbsp;Xiaoling Cao","doi":"10.1016/j.icheatmasstransfer.2025.108848","DOIUrl":null,"url":null,"abstract":"<div><div>Although two-phase closed thermosyphons (TPCTs) with low surface tension fluids are increasingly being applied in various fields, existing studies mainly focus on TPCTs with water as the working fluid under different wettability, and there is a lack of research on the condensation dynamics of low surface tension fluids in TPCTs under varying wettability. This paper addresses this gap by presenting a novel CFD model that integrates a dynamic condensation mass transfer time relaxation parameter into the Lee model and couples it with the contact angle model. The results indicate that the numerical model is more accurate in simulating the formation of a liquid film when the liquid phase is set for the primary phase and the density model of the vapor phase is used as an incompressible ideal gas. When low surface tension working fluids, such as methanol and ethanol, are used in TPCTs, the size of bubbles and boiling intensity in the evaporator are lower compared to when water is used as the working fluid. Surface tension and gravity induce the formation of a fluctuating condensate film on the condenser of a methanol-TPCT. The liquid film in the condenser of the ethanol-TPCT is approximately 1.5 times thicker than that of the methanol-TPCT. As the contact angle increases, the thickness of the liquid film on the wall decreases, leading to the phenomenon of temperature rise on the upper wall of the evaporator. These advancements provide a design tool for next-generation TPCTs in applications like data center cooling and hyperloop systems.</div></div>","PeriodicalId":332,"journal":{"name":"International Communications in Heat and Mass Transfer","volume":"164 ","pages":"Article 108848"},"PeriodicalIF":6.4000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Communications in Heat and Mass Transfer","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0735193325002738","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 0

Abstract

Although two-phase closed thermosyphons (TPCTs) with low surface tension fluids are increasingly being applied in various fields, existing studies mainly focus on TPCTs with water as the working fluid under different wettability, and there is a lack of research on the condensation dynamics of low surface tension fluids in TPCTs under varying wettability. This paper addresses this gap by presenting a novel CFD model that integrates a dynamic condensation mass transfer time relaxation parameter into the Lee model and couples it with the contact angle model. The results indicate that the numerical model is more accurate in simulating the formation of a liquid film when the liquid phase is set for the primary phase and the density model of the vapor phase is used as an incompressible ideal gas. When low surface tension working fluids, such as methanol and ethanol, are used in TPCTs, the size of bubbles and boiling intensity in the evaporator are lower compared to when water is used as the working fluid. Surface tension and gravity induce the formation of a fluctuating condensate film on the condenser of a methanol-TPCT. The liquid film in the condenser of the ethanol-TPCT is approximately 1.5 times thicker than that of the methanol-TPCT. As the contact angle increases, the thickness of the liquid film on the wall decreases, leading to the phenomenon of temperature rise on the upper wall of the evaporator. These advancements provide a design tool for next-generation TPCTs in applications like data center cooling and hyperloop systems.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
11.00
自引率
10.00%
发文量
648
审稿时长
32 days
期刊介绍: International Communications in Heat and Mass Transfer serves as a world forum for the rapid dissemination of new ideas, new measurement techniques, preliminary findings of ongoing investigations, discussions, and criticisms in the field of heat and mass transfer. Two types of manuscript will be considered for publication: communications (short reports of new work or discussions of work which has already been published) and summaries (abstracts of reports, theses or manuscripts which are too long for publication in full). Together with its companion publication, International Journal of Heat and Mass Transfer, with which it shares the same Board of Editors, this journal is read by research workers and engineers throughout the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信