{"title":"Improving energy efficiency through forecast-driven control in hybrid heat pumps","authors":"Marco Bizzarri,&nbsp;Paolo Conti,&nbsp;Eva Schito,&nbsp;Daniele Testi","doi":"10.1016/j.enconman.2025.119737","DOIUrl":null,"url":null,"abstract":"<div><div>Hybrid heat pumps (HHPs) are increasingly used for residential space heating, especially where stand-alone heat pumps (HPs) are inefficient. Typically, HHPs and HVAC systems controls rely on simple rule-based approaches. Smart controllers that employ building-system modeling can improve energy efficiency by determining which heat generation unit to activate and setting the supply water temperature according to actual building heat demand. Data-driven models are particularly suitable for widespread use, as they can self-learn building thermal characteristics and optimize system operation. In this study, we employed an autoregressive model to forecast short-term hourly energy demand and the corresponding water supply temperature to the heat emitters. These predictions helped to estimate generators performance and select the optimal unit to minimize energy costs while meeting heat demand. The predictive control procedure was tested on various case studies, both simulated and field-monitored, representative of the Italian housing stock. Results showed that in non-renovated buildings with radiators, the predictive control strategy can reduce operating costs by up to 20% compared to current commercial HHP controls. This improvement was mainly due to better supply temperature set-point evaluation and increased HP use. Similar benefits were observed in environmental and primary energy metrics. Conversely, in newer, well-insulated houses with low-temperature emitters, current controls are already efficient. Finally, we showed that the proposed control strategy deviates less than 3% from an ideal prediction and control in realistic on-field monitored test cases, representing a valuable trade-off between achievable benefits, data requirements, computational efforts, and implementation feasibility in real industrial HHP devices.</div></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":"332 ","pages":"Article 119737"},"PeriodicalIF":9.9000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0196890425002602","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Hybrid heat pumps (HHPs) are increasingly used for residential space heating, especially where stand-alone heat pumps (HPs) are inefficient. Typically, HHPs and HVAC systems controls rely on simple rule-based approaches. Smart controllers that employ building-system modeling can improve energy efficiency by determining which heat generation unit to activate and setting the supply water temperature according to actual building heat demand. Data-driven models are particularly suitable for widespread use, as they can self-learn building thermal characteristics and optimize system operation. In this study, we employed an autoregressive model to forecast short-term hourly energy demand and the corresponding water supply temperature to the heat emitters. These predictions helped to estimate generators performance and select the optimal unit to minimize energy costs while meeting heat demand. The predictive control procedure was tested on various case studies, both simulated and field-monitored, representative of the Italian housing stock. Results showed that in non-renovated buildings with radiators, the predictive control strategy can reduce operating costs by up to 20% compared to current commercial HHP controls. This improvement was mainly due to better supply temperature set-point evaluation and increased HP use. Similar benefits were observed in environmental and primary energy metrics. Conversely, in newer, well-insulated houses with low-temperature emitters, current controls are already efficient. Finally, we showed that the proposed control strategy deviates less than 3% from an ideal prediction and control in realistic on-field monitored test cases, representing a valuable trade-off between achievable benefits, data requirements, computational efforts, and implementation feasibility in real industrial HHP devices.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy Conversion and Management
Energy Conversion and Management 工程技术-力学
CiteScore
19.00
自引率
11.50%
发文量
1304
审稿时长
17 days
期刊介绍: The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics. The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信