Pressure drop study of two-phase flows under condensation within capillary tubes

Q1 Chemical Engineering
K. G. Domiciano , M. B. H. Mantelli , M. Mameli , S. Filippeschi
{"title":"Pressure drop study of two-phase flows under condensation within capillary tubes","authors":"K. G. Domiciano ,&nbsp;M. B. H. Mantelli ,&nbsp;M. Mameli ,&nbsp;S. Filippeschi","doi":"10.1016/j.ijft.2025.101169","DOIUrl":null,"url":null,"abstract":"<div><div>In the present study, an experimental investigation of pressure drops in two-phase flows within capillary tubes operating at low mass flow rates under condensation conditions was conducted. The primary objective was to understand the mechanics driving such flows to support the design of condensers for small two-phase devices, such as miniature loop heat pipes. A simple yet innovative experimental setup was developed, wherein the flows, similar to those in heat pipe technologies, were passively induced by vapor pressure. Pressure drops in two-phase flows under diabatic conditions were measured. Water and ethanol were tested, with mass flow rates below 6 × 10⁻⁵ kg/s and mass fluxes ranging from 15.5 to 209.3 kg/m²s. Copper and high-quality PVC capillary tubes with diameters between 0.446 mm and 1.010 mm were employed. Under diabatic conditions, the vapor entered the tubes with an initial vapor quality of one and condensed as it traveled through the tubes, leaving with vapor qualities between approximately 70 % and 90 %. In some cases, the condensed liquid coalesced into large plugs that completely filled the tube's cross-section, leading to confined flow conditions. These liquid plugs required higher vapor pressures to be pumped along the tube. Consequently, the pressure drop behavior was highly dependent on the flow regime. Lower pressure drops were observed when the vapor flowed at high velocities, causing the liquid to disperse into small droplets. Conversely, higher pressure drops occurred when the condensate formed blockages within the tube. The pressure drops in the flow ranged from 958 Pa to 75.4 kPa for water and 524 Pa to 59.8 kPa for ethanol. These values were consistently between the single-phase vapor and liquid pressure drops, typically closer to the latter. Notably, the observed pressure drops were significantly lower than those predicted by conventional literature correlations for two-phase flows. Furthermore, the study discusses the critical roles of pressure drops induced by fluid phase changes and the influence of capillary forces due to the confined liquid flows.</div></div>","PeriodicalId":36341,"journal":{"name":"International Journal of Thermofluids","volume":"27 ","pages":"Article 101169"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Thermofluids","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666202725001168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Chemical Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

In the present study, an experimental investigation of pressure drops in two-phase flows within capillary tubes operating at low mass flow rates under condensation conditions was conducted. The primary objective was to understand the mechanics driving such flows to support the design of condensers for small two-phase devices, such as miniature loop heat pipes. A simple yet innovative experimental setup was developed, wherein the flows, similar to those in heat pipe technologies, were passively induced by vapor pressure. Pressure drops in two-phase flows under diabatic conditions were measured. Water and ethanol were tested, with mass flow rates below 6 × 10⁻⁵ kg/s and mass fluxes ranging from 15.5 to 209.3 kg/m²s. Copper and high-quality PVC capillary tubes with diameters between 0.446 mm and 1.010 mm were employed. Under diabatic conditions, the vapor entered the tubes with an initial vapor quality of one and condensed as it traveled through the tubes, leaving with vapor qualities between approximately 70 % and 90 %. In some cases, the condensed liquid coalesced into large plugs that completely filled the tube's cross-section, leading to confined flow conditions. These liquid plugs required higher vapor pressures to be pumped along the tube. Consequently, the pressure drop behavior was highly dependent on the flow regime. Lower pressure drops were observed when the vapor flowed at high velocities, causing the liquid to disperse into small droplets. Conversely, higher pressure drops occurred when the condensate formed blockages within the tube. The pressure drops in the flow ranged from 958 Pa to 75.4 kPa for water and 524 Pa to 59.8 kPa for ethanol. These values were consistently between the single-phase vapor and liquid pressure drops, typically closer to the latter. Notably, the observed pressure drops were significantly lower than those predicted by conventional literature correlations for two-phase flows. Furthermore, the study discusses the critical roles of pressure drops induced by fluid phase changes and the influence of capillary forces due to the confined liquid flows.
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Thermofluids
International Journal of Thermofluids Engineering-Mechanical Engineering
CiteScore
10.10
自引率
0.00%
发文量
111
审稿时长
66 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信