{"title":"Machine Learning-Based Rapid Prediction of Torsional Performance of Personalized Peripheral Artery Stent","authors":"Xiang Shen,&nbsp;Jiahao Chen,&nbsp;Zewen He,&nbsp;Yue Xu,&nbsp;Qiang Liu,&nbsp;Hongyu Liang,&nbsp;Hengfeng Yan","doi":"10.1002/cnm.70029","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The complex mechanical environment of peripheral arteries makes stents with poor torsional performance more prone to fracture, and stent fracture is considered a precursor to in-stent restenosis (ISR). Therefore, studying the torsional performance of stents is crucial. However, while the finite element method (FEM) can accurately simulate the torsional behavior of stents, its time-consuming nature makes it difficult to meet the rapid design requirements for individualized stents. Thus, integrating efficient machine learning (ML) models into the stent design process may be a viable approach. In this study, a machine learning-based rapid prediction method was established to achieve the rapid prediction of torsional performance of personalized peripheral artery stents. A dataset containing 200 different stent designs was generated using Latin Hypercube Sampling (LHS) and FEM. The dataset was divided into a training set (160 samples) and a test set (40 samples). Based on four input variables—the length of strut ring (LS), the width of strut (WS), the width of link (WL), and the thickness of stent (T)—the predictive performance of polynomial regression (PR), random forest regression (RFR), and support vector regression (SVR) for the twist metric (TM) was compared. To simulate the real-world application of ML models, after training and testing the ML models, the entire dataset (combining the training and test sets) was used for re-learning while keeping the control parameters unchanged. A validation set (10 samples) was generated through sampling and FEM, and the re-learned ML models were used to predict and validate their performance. By comprehensively comparing the predictive performance of the ML models on the training set, test set, and validation set, the algorithm performance ranked as follows: PR&gt;SVR&gt;RFR. The PR model achieved a mean absolute error (MAE) of (training set = 0.02847; test set = 0.03083; validation set = 0.04311) and a coefficient of determination (<i>R</i><sup>2</sup>) of (training set = 0.95148; test set = 0.97822; validation set = 0.94397). This method can effectively shorten the design cycle of stents and meet the need for personalized stent rapid design and choice. In addition, this method can also be extended to predict other mechanical properties of the stent and can be used in stent multi-objective design optimization.</p>\n </div>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"41 3","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.70029","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The complex mechanical environment of peripheral arteries makes stents with poor torsional performance more prone to fracture, and stent fracture is considered a precursor to in-stent restenosis (ISR). Therefore, studying the torsional performance of stents is crucial. However, while the finite element method (FEM) can accurately simulate the torsional behavior of stents, its time-consuming nature makes it difficult to meet the rapid design requirements for individualized stents. Thus, integrating efficient machine learning (ML) models into the stent design process may be a viable approach. In this study, a machine learning-based rapid prediction method was established to achieve the rapid prediction of torsional performance of personalized peripheral artery stents. A dataset containing 200 different stent designs was generated using Latin Hypercube Sampling (LHS) and FEM. The dataset was divided into a training set (160 samples) and a test set (40 samples). Based on four input variables—the length of strut ring (LS), the width of strut (WS), the width of link (WL), and the thickness of stent (T)—the predictive performance of polynomial regression (PR), random forest regression (RFR), and support vector regression (SVR) for the twist metric (TM) was compared. To simulate the real-world application of ML models, after training and testing the ML models, the entire dataset (combining the training and test sets) was used for re-learning while keeping the control parameters unchanged. A validation set (10 samples) was generated through sampling and FEM, and the re-learned ML models were used to predict and validate their performance. By comprehensively comparing the predictive performance of the ML models on the training set, test set, and validation set, the algorithm performance ranked as follows: PR>SVR>RFR. The PR model achieved a mean absolute error (MAE) of (training set = 0.02847; test set = 0.03083; validation set = 0.04311) and a coefficient of determination (R2) of (training set = 0.95148; test set = 0.97822; validation set = 0.94397). This method can effectively shorten the design cycle of stents and meet the need for personalized stent rapid design and choice. In addition, this method can also be extended to predict other mechanical properties of the stent and can be used in stent multi-objective design optimization.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信