The HbA1c-Adjusted Slow Valley Height Ratio, a Depth Indicator of the Valley Between HbA1c and HbA0 Measured by High-Performance Liquid Chromatography, Is Useful for the Diagnosis of Hb Toranomon.
Masafumi Koga, Aki Ishido, Yasushi Inoue, Yoshimi Imai, Hiroko Ijima, Hideaki Jinnouchi, Jun Murai, Mika Ito
{"title":"The HbA1c-Adjusted Slow Valley Height Ratio, a Depth Indicator of the Valley Between HbA1c and HbA0 Measured by High-Performance Liquid Chromatography, Is Useful for the Diagnosis of Hb Toranomon.","authors":"Masafumi Koga, Aki Ishido, Yasushi Inoue, Yoshimi Imai, Hiroko Ijima, Hideaki Jinnouchi, Jun Murai, Mika Ito","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>HbA1c values in patients with Hb Toranomon, a hemoglobin variant, are falsely high when measured with the Tosoh high-performance liquid chromatography (HPLC) analyzer. Moreover, a phenomenon has been observed in which the valley between HbA1c and HbA0 [slow valley (SV)] appears shallow on the chromatograms measured by the Tosoh HPLC analyzer in patients with Hb Toranomon. In the present study, the usefulness of the indicator, HbA1c (A1c)-adjusted SV height rate (AaSVHR), as a screening test for Hb Toranomon to quantify the SV height (SVH) was investigated.</p><p><strong>Methods: </strong>This study included six patients with Hb Toranomon and 100 control participants, comprising 50 diabetic patients and 50 non-diabetic participants. The SVH between HbA1c and HbA0 and the height of HbA1c (A1cH) on HPLC (G9) chromatograms were measured to determine the ratio of SVH to A1cH [SVH ratio (SVHR)]. Given that the SVHR obtained showed a significant negative correlation with HbA1c measured by HPLC, SVHR was corrected with HbA1c [A1c-adjusted SVHR (AaSVHR)], but it showed no significant correlation with HbA1c.</p><p><strong>Results: </strong>AaSVHR exceeded 14% across all participants with Hb Toranomon, but it was no more than 14% in all control participants.</p><p><strong>Conclusion: </strong>AaSVHR measurements are useful as an Hb Toranomon screening test in patients whose HbA1c measured with a Tosoh HPLC analyzer is falsely high. A high AaSVHR exceeding 14% raises a strong suspicion for the presence of a hemoglobin variant including Hb Toranomon.</p>","PeriodicalId":8228,"journal":{"name":"Annals of clinical and laboratory science","volume":"55 1","pages":"108-114"},"PeriodicalIF":1.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of clinical and laboratory science","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: HbA1c values in patients with Hb Toranomon, a hemoglobin variant, are falsely high when measured with the Tosoh high-performance liquid chromatography (HPLC) analyzer. Moreover, a phenomenon has been observed in which the valley between HbA1c and HbA0 [slow valley (SV)] appears shallow on the chromatograms measured by the Tosoh HPLC analyzer in patients with Hb Toranomon. In the present study, the usefulness of the indicator, HbA1c (A1c)-adjusted SV height rate (AaSVHR), as a screening test for Hb Toranomon to quantify the SV height (SVH) was investigated.
Methods: This study included six patients with Hb Toranomon and 100 control participants, comprising 50 diabetic patients and 50 non-diabetic participants. The SVH between HbA1c and HbA0 and the height of HbA1c (A1cH) on HPLC (G9) chromatograms were measured to determine the ratio of SVH to A1cH [SVH ratio (SVHR)]. Given that the SVHR obtained showed a significant negative correlation with HbA1c measured by HPLC, SVHR was corrected with HbA1c [A1c-adjusted SVHR (AaSVHR)], but it showed no significant correlation with HbA1c.
Results: AaSVHR exceeded 14% across all participants with Hb Toranomon, but it was no more than 14% in all control participants.
Conclusion: AaSVHR measurements are useful as an Hb Toranomon screening test in patients whose HbA1c measured with a Tosoh HPLC analyzer is falsely high. A high AaSVHR exceeding 14% raises a strong suspicion for the presence of a hemoglobin variant including Hb Toranomon.
期刊介绍:
The Annals of Clinical & Laboratory Science
welcomes manuscripts that report research in clinical
science, including pathology, clinical chemistry,
biotechnology, molecular biology, cytogenetics,
microbiology, immunology, hematology, transfusion
medicine, organ and tissue transplantation, therapeutics, toxicology, and clinical informatics.