Evaluating Indoor Thermal Comfort of the Elderly During Summer in the Hot-Humid and Less-Windy Climate

IF 4.3 2区 环境科学与生态学 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Indoor air Pub Date : 2025-03-17 DOI:10.1155/ina/8864602
Li Wang, Xian Yang, Huabin Xie, Qi Wang, Jiang He
{"title":"Evaluating Indoor Thermal Comfort of the Elderly During Summer in the Hot-Humid and Less-Windy Climate","authors":"Li Wang,&nbsp;Xian Yang,&nbsp;Huabin Xie,&nbsp;Qi Wang,&nbsp;Jiang He","doi":"10.1155/ina/8864602","DOIUrl":null,"url":null,"abstract":"<p>There is still a lack of research on the evaluation of summer thermal comfort for the elderly. This study conducted a questionnaire survey and indoor thermal environment measurement in Nanning, China, with a hot-humid and less-windy climate. Six hundred elderly subjects were selected to answer the thermal sensation questionnaire in the naturally ventilated residential buildings during the summer. The analysis results of the collected data show that the neutral temperature for the local elderly is 28.0°C, and the range of operative temperature for 80% thermal acceptability is 26.4°C–29.5°C. An adaptive thermal comfort model was developed using the measured data, and its predicted thermal neutral temperature is 28.1°C, nearly equal to the measured value (28.0°C). The thermal neutral temperatures for the local male and female elderly are 27.7°C and 28.2°C, respectively, which reveals that there are gender differences in the thermal comfort. It was also found that the outdoor air temperature has a significant impact on the thermal neutral temperature, and the developed adaptive thermal comfort model can more accurately predict the indoor thermal comfort of the local elderly. The findings in this study can provide theoretical support and supporting data for the indoor thermal environment design of new old-age facilities and aging-adapted renovation of existing buildings in hot and humid climates.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2025 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/ina/8864602","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor air","FirstCategoryId":"93","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/ina/8864602","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

There is still a lack of research on the evaluation of summer thermal comfort for the elderly. This study conducted a questionnaire survey and indoor thermal environment measurement in Nanning, China, with a hot-humid and less-windy climate. Six hundred elderly subjects were selected to answer the thermal sensation questionnaire in the naturally ventilated residential buildings during the summer. The analysis results of the collected data show that the neutral temperature for the local elderly is 28.0°C, and the range of operative temperature for 80% thermal acceptability is 26.4°C–29.5°C. An adaptive thermal comfort model was developed using the measured data, and its predicted thermal neutral temperature is 28.1°C, nearly equal to the measured value (28.0°C). The thermal neutral temperatures for the local male and female elderly are 27.7°C and 28.2°C, respectively, which reveals that there are gender differences in the thermal comfort. It was also found that the outdoor air temperature has a significant impact on the thermal neutral temperature, and the developed adaptive thermal comfort model can more accurately predict the indoor thermal comfort of the local elderly. The findings in this study can provide theoretical support and supporting data for the indoor thermal environment design of new old-age facilities and aging-adapted renovation of existing buildings in hot and humid climates.

Abstract Image

评估炎热-潮湿和少风气候下老年人夏季室内热舒适度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Indoor air
Indoor air 环境科学-工程:环境
CiteScore
10.80
自引率
10.30%
发文量
175
审稿时长
3 months
期刊介绍: The quality of the environment within buildings is a topic of major importance for public health. Indoor Air provides a location for reporting original research results in the broad area defined by the indoor environment of non-industrial buildings. An international journal with multidisciplinary content, Indoor Air publishes papers reflecting the broad categories of interest in this field: health effects; thermal comfort; monitoring and modelling; source characterization; ventilation and other environmental control techniques. The research results present the basic information to allow designers, building owners, and operators to provide a healthy and comfortable environment for building occupants, as well as giving medical practitioners information on how to deal with illnesses related to the indoor environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信