A cutting-edge design of a novel electrochemical voltammetric nanosensor modified with molecularly imprinted polymer along with multi-walled carbon nanotubes for selective safinamide recognition

IF 4.1 Q1 CHEMISTRY, ANALYTICAL
Engy A. Ibrahim , Samah S. Saad , Maha A. Hegazy , Laila E. Abdel Fattah , Hoda M. Marzouk
{"title":"A cutting-edge design of a novel electrochemical voltammetric nanosensor modified with molecularly imprinted polymer along with multi-walled carbon nanotubes for selective safinamide recognition","authors":"Engy A. Ibrahim ,&nbsp;Samah S. Saad ,&nbsp;Maha A. Hegazy ,&nbsp;Laila E. Abdel Fattah ,&nbsp;Hoda M. Marzouk","doi":"10.1016/j.talo.2025.100428","DOIUrl":null,"url":null,"abstract":"<div><div>Safinamide mesylate (SAF) is an innovative adjuvant treatment for managing wearing-off symptoms in Parkinson's disease (PD). Our novel approach involves the development of a differential pulse voltammetric (DPV) technique for SAF determination. This method utilizes a carbon nanocomposite paste electrode that is modified by a molecularly imprinted polymer (MIP) to serve as a recognition element for SAF. Additionally, multi-walled carbon nanotubes (MWCNTs) are incorporated to enhance the electrode's sensitivity. The MIP was subjected to a thorough characterization process, including analysis of rebinding, differential scanning calorimetry, field emission scanning electron microscopy, and Fourier-transform infrared spectroscopy. The cavities of the MIP recognize and bind to the medication, functioning as reliable host-tailored artificial receptors. The resulting modified electrode functions as a voltammetric sensor, enabling the nano detection of SAF. The fabricated MIP/MWCNTs-CPE demonstrates a linear range from 0.3 to 22.0 μg/mL and excellent sensitivity, with a limit of detection (LOD) of 0.079 μg/mL. According to ICH guidelines, the enhanced method has been validated for quality control testing on the pharmaceutical product and spiked human plasma. The proposed method was found to be practical, reliable, cost-effective, and efficient means of estimating the investigated drug. The method's sustainability was assessed by analyzing its scores for greenness, blueness, and whiteness. Therefore, this method has the potential to be a long-term, practical analytical tool for in vitro studies and quality control laboratories.</div></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"11 ","pages":"Article 100428"},"PeriodicalIF":4.1000,"publicationDate":"2025-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831925000311","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Safinamide mesylate (SAF) is an innovative adjuvant treatment for managing wearing-off symptoms in Parkinson's disease (PD). Our novel approach involves the development of a differential pulse voltammetric (DPV) technique for SAF determination. This method utilizes a carbon nanocomposite paste electrode that is modified by a molecularly imprinted polymer (MIP) to serve as a recognition element for SAF. Additionally, multi-walled carbon nanotubes (MWCNTs) are incorporated to enhance the electrode's sensitivity. The MIP was subjected to a thorough characterization process, including analysis of rebinding, differential scanning calorimetry, field emission scanning electron microscopy, and Fourier-transform infrared spectroscopy. The cavities of the MIP recognize and bind to the medication, functioning as reliable host-tailored artificial receptors. The resulting modified electrode functions as a voltammetric sensor, enabling the nano detection of SAF. The fabricated MIP/MWCNTs-CPE demonstrates a linear range from 0.3 to 22.0 μg/mL and excellent sensitivity, with a limit of detection (LOD) of 0.079 μg/mL. According to ICH guidelines, the enhanced method has been validated for quality control testing on the pharmaceutical product and spiked human plasma. The proposed method was found to be practical, reliable, cost-effective, and efficient means of estimating the investigated drug. The method's sustainability was assessed by analyzing its scores for greenness, blueness, and whiteness. Therefore, this method has the potential to be a long-term, practical analytical tool for in vitro studies and quality control laboratories.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信