Abdullah S Alhunayni, Nehal F Albelasy, Ahmad M Hafez
{"title":"Evaluation of Different Surface Roughening Techniques on Clear Aligner Attachments Bonded to Monolithic Zirconia: <i>In Vitro</i> Study.","authors":"Abdullah S Alhunayni, Nehal F Albelasy, Ahmad M Hafez","doi":"10.5005/jp-journals-10024-3793","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The objective of this study is to assess the impact of three different surface etching techniques and two composite materials on surface roughness (<i>R</i><sub>a</sub>) and the shear bond strength (SBS) of clear aligner attachments bonded to monolithic zirconia (MZ).</p><p><strong>Materials and methods: </strong>Sixty-six MZ disks were divided into three main groups (<i>n</i> = 22) according to the surface treatment method: group I: hydrofluoric acid (HFA) 9.5%, group II: 50 µm aluminum oxide (Al<sub>2</sub>O<sub>3</sub>) sandblasting, and group III: Er:Cr:YSGG laser. Each group was then subdivided into two subgroups according to the composite material (<i>n</i> = 11) used for bonding of the attachment, either packable composite Filtek Z350 or composite Filtek Z250. Clear aligner attachments were then bonded to the disks, and measurements of <i>R</i><sub>a</sub> and SBS were taken. Statistical analysis was carried out using the Kruskal-Wallis test and two-way analysis of variance.</p><p><strong>Results: </strong>The HFA groups showed the highest SBS (11.29 ± 2.83 MPa) and <i>R</i><sub>a</sub> (0.82 µm), while the laser groups exhibited the lowest SBS (8.29 ± 2.38 MPa) and <i>R</i><sub>a</sub> (0.634 µm). In Filtek Z350, there was a significant difference observed between the subgroups regarding SBS but not in Filtek Z250 subgroups.</p><p><strong>Conclusion: </strong>The 9.5% HFA provided the highest SBS value in comparison with Er:Cr:YSGG laser and sandblasting (<i>p</i> <0.05).</p><p><strong>Clinical significance: </strong>This study has the potential to benefit both orthodontists and patients by providing insights into techniques that can improve the bond strength and longevity of clear aligner attachments to MZ. How to cite this article: Alhunayni AS, Albelasy NF, Hafez AM. Evaluation of Different Surface Roughening Techniques on Clear Aligner Attachments Bonded to Monolithic Zirconia: <i>In Vitro</i> Study. J Contemp Dent Pract 2024;25(12):1104-1109.</p>","PeriodicalId":35792,"journal":{"name":"Journal of Contemporary Dental Practice","volume":"25 12","pages":"1104-1109"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Dental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10024-3793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: The objective of this study is to assess the impact of three different surface etching techniques and two composite materials on surface roughness (Ra) and the shear bond strength (SBS) of clear aligner attachments bonded to monolithic zirconia (MZ).
Materials and methods: Sixty-six MZ disks were divided into three main groups (n = 22) according to the surface treatment method: group I: hydrofluoric acid (HFA) 9.5%, group II: 50 µm aluminum oxide (Al2O3) sandblasting, and group III: Er:Cr:YSGG laser. Each group was then subdivided into two subgroups according to the composite material (n = 11) used for bonding of the attachment, either packable composite Filtek Z350 or composite Filtek Z250. Clear aligner attachments were then bonded to the disks, and measurements of Ra and SBS were taken. Statistical analysis was carried out using the Kruskal-Wallis test and two-way analysis of variance.
Results: The HFA groups showed the highest SBS (11.29 ± 2.83 MPa) and Ra (0.82 µm), while the laser groups exhibited the lowest SBS (8.29 ± 2.38 MPa) and Ra (0.634 µm). In Filtek Z350, there was a significant difference observed between the subgroups regarding SBS but not in Filtek Z250 subgroups.
Conclusion: The 9.5% HFA provided the highest SBS value in comparison with Er:Cr:YSGG laser and sandblasting (p <0.05).
Clinical significance: This study has the potential to benefit both orthodontists and patients by providing insights into techniques that can improve the bond strength and longevity of clear aligner attachments to MZ. How to cite this article: Alhunayni AS, Albelasy NF, Hafez AM. Evaluation of Different Surface Roughening Techniques on Clear Aligner Attachments Bonded to Monolithic Zirconia: In Vitro Study. J Contemp Dent Pract 2024;25(12):1104-1109.
期刊介绍:
The Journal of Contemporary Dental Practice (JCDP), is a peer-reviewed, open access MEDLINE indexed journal. The journal’s full text is available online at http://www.thejcdp.com. The journal allows free access (open access) to its contents. Articles with clinical relevance will be given preference for publication. The Journal publishes original research papers, review articles, rare and novel case reports, and clinical techniques. Manuscripts are invited from all specialties of dentistry i.e., conservative dentistry and endodontics, dentofacial orthopedics and orthodontics, oral medicine and radiology, oral pathology, oral surgery, orodental diseases, pediatric dentistry, implantology, periodontics, clinical aspects of public health dentistry, and prosthodontics.