A novel preoperative prosthetic position planning algorithm for total hip arthroplasty based on the no-impingement principle: A case study.

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Tao Feng, Hao Tang, Xiaogang Zhang, Yali Zhang, Yixin Zhou, Zhongmin Jin
{"title":"A novel preoperative prosthetic position planning algorithm for total hip arthroplasty based on the no-impingement principle: A case study.","authors":"Tao Feng, Hao Tang, Xiaogang Zhang, Yali Zhang, Yixin Zhou, Zhongmin Jin","doi":"10.1177/09544119251319960","DOIUrl":null,"url":null,"abstract":"<p><p>Most preoperative planning calculations of impingement-free range of motion (IFROM) and impingement-free safe zone (IFSZ) rarely consider non-standard shaped prostheses and bony impingement (BI) for total hip arthroplasty (THA). This research developed a novel algorithm that considers BI, prosthetic impingement, pelvic tilt angle (<i>PT</i>) in the sagittal plane, and non-standard-shaped hip prostheses. This research aimed to investigate the effect of BI and <i>PT</i> on hip IFROM, IFSZ, and the BI rate. Using this algorithm to calculate a case, we found that when considering BI, (1) the upper limit of the hip IFROM was decreased, and the different <i>PT</i> affected the upper limit of the hip IFROM of various movements; (2) the BI rate of the flat-rim liner in standing and sitting postures were 54.6% and 67%; and (3) the maximum IFSZ size of the flat-rim liner was reduced by 12%, the reduction rate of the combined pelvic position with a non-zero IFSZ size was 83.2% for the flat-rim liner. Consideration of BI further reduces the IFROM, the IFSZ size, and the number of the combined position of the pelvis with a non-zero IFSZ size of the hip joint. Importantly, this algorithm provides a reliable tool for personalized prosthesis positioning for THA. This algorithm has excellent applications in personalized surgical planning and surgical robotics.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"9544119251319960"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119251319960","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Most preoperative planning calculations of impingement-free range of motion (IFROM) and impingement-free safe zone (IFSZ) rarely consider non-standard shaped prostheses and bony impingement (BI) for total hip arthroplasty (THA). This research developed a novel algorithm that considers BI, prosthetic impingement, pelvic tilt angle (PT) in the sagittal plane, and non-standard-shaped hip prostheses. This research aimed to investigate the effect of BI and PT on hip IFROM, IFSZ, and the BI rate. Using this algorithm to calculate a case, we found that when considering BI, (1) the upper limit of the hip IFROM was decreased, and the different PT affected the upper limit of the hip IFROM of various movements; (2) the BI rate of the flat-rim liner in standing and sitting postures were 54.6% and 67%; and (3) the maximum IFSZ size of the flat-rim liner was reduced by 12%, the reduction rate of the combined pelvic position with a non-zero IFSZ size was 83.2% for the flat-rim liner. Consideration of BI further reduces the IFROM, the IFSZ size, and the number of the combined position of the pelvis with a non-zero IFSZ size of the hip joint. Importantly, this algorithm provides a reliable tool for personalized prosthesis positioning for THA. This algorithm has excellent applications in personalized surgical planning and surgical robotics.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信