Influence of an artificial intelligence-based application on the accuracy of complete arch implant scans recorded by using an intraoral scanner.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Marta Revilla-León, Rocio Cascos, Abdul B Barmak, John C Kois, Miguel Gómez-Polo
{"title":"Influence of an artificial intelligence-based application on the accuracy of complete arch implant scans recorded by using an intraoral scanner.","authors":"Marta Revilla-León, Rocio Cascos, Abdul B Barmak, John C Kois, Miguel Gómez-Polo","doi":"10.1016/j.prosdent.2025.02.010","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Artificial intelligence (AI)-based applications have been integrated into intraoral scanner (IOS) programs aiming to assist the digitizing procedure, including the automatic alignment of the computer-aided design (CAD) file of the selected implant scan body (ISB). However, the impact of this AI-based application on the accuracy of complete arch implant scans remains unknown.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to assess the impact of an AI-based application on the accuracy of complete arch implant scans recorded by using an IOS.</p><p><strong>Material and methods: </strong>A maxillary edentulous stone cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was obtained. Three groups were created based on the technique used to record complete arch implant scans by using an IOS (i700): prescan with the posterior ISB scan activating (Pre-AI group) or disabling the AI-based application (Pre-NoAI group) or obtaining a complete arch implant scan without prescan (NoPre group) (n=10). A complete arch scan involving the implant abutments was obtained (prescan) and duplicated 20 times. Then, an ISB (Elos Accurate IO 2C-A) was hand tightened into each implant abutment analog. In the Pre-AI group, for each duplicated prescan, each ISB was scanned until each scanned ISB was automatically aligned with the CAD file by the AI-based program. In the Pre-NoAI group, for each duplicated prescan, the ISBs were digitized to obtain the experimental complete arch implant scans. In the NoPre group, a complete arch implant scan was obtained. Lastly, a laboratory scan (reference scan) was obtained (T710). For each scan, an implant-supported bar was designed by using a program (DentalCAD). The bar designs were imported into another program (Geomagic), and linear and angular measurements among the implants were made. The measurements obtained in the control scan were used as a reference to measure the scanning distortion of each specimen. A 1-way Welch ANOVA test followed by the post hoc pairwise multiple comparison Tukey test was used to analyze trueness (α=.05). The Levene test was used to analyze precision (α=.05).</p><p><strong>Results: </strong>Significant linear (P<.001) trueness discrepancies were found among the groups. The Pre-AI group obtained significantly worse linear trueness than the other 2 groups. Additionally, significant angular trueness (P<.001) and precision (P<.001) discrepancies were revealed among the groups. The Pre-AI group obtained significantly worse angular trueness and precision than the other groups tested.</p><p><strong>Conclusions: </strong>The implant scanning technique impacted the 3-dimensional implant positions recorded by using the IOS tested.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.02.010","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: Artificial intelligence (AI)-based applications have been integrated into intraoral scanner (IOS) programs aiming to assist the digitizing procedure, including the automatic alignment of the computer-aided design (CAD) file of the selected implant scan body (ISB). However, the impact of this AI-based application on the accuracy of complete arch implant scans remains unknown.

Purpose: The purpose of this in vitro study was to assess the impact of an AI-based application on the accuracy of complete arch implant scans recorded by using an IOS.

Material and methods: A maxillary edentulous stone cast with 6 implant abutment analogs (MultiUnit Abutment Plus Replica) was obtained. Three groups were created based on the technique used to record complete arch implant scans by using an IOS (i700): prescan with the posterior ISB scan activating (Pre-AI group) or disabling the AI-based application (Pre-NoAI group) or obtaining a complete arch implant scan without prescan (NoPre group) (n=10). A complete arch scan involving the implant abutments was obtained (prescan) and duplicated 20 times. Then, an ISB (Elos Accurate IO 2C-A) was hand tightened into each implant abutment analog. In the Pre-AI group, for each duplicated prescan, each ISB was scanned until each scanned ISB was automatically aligned with the CAD file by the AI-based program. In the Pre-NoAI group, for each duplicated prescan, the ISBs were digitized to obtain the experimental complete arch implant scans. In the NoPre group, a complete arch implant scan was obtained. Lastly, a laboratory scan (reference scan) was obtained (T710). For each scan, an implant-supported bar was designed by using a program (DentalCAD). The bar designs were imported into another program (Geomagic), and linear and angular measurements among the implants were made. The measurements obtained in the control scan were used as a reference to measure the scanning distortion of each specimen. A 1-way Welch ANOVA test followed by the post hoc pairwise multiple comparison Tukey test was used to analyze trueness (α=.05). The Levene test was used to analyze precision (α=.05).

Results: Significant linear (P<.001) trueness discrepancies were found among the groups. The Pre-AI group obtained significantly worse linear trueness than the other 2 groups. Additionally, significant angular trueness (P<.001) and precision (P<.001) discrepancies were revealed among the groups. The Pre-AI group obtained significantly worse angular trueness and precision than the other groups tested.

Conclusions: The implant scanning technique impacted the 3-dimensional implant positions recorded by using the IOS tested.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信