Status of Cardiac Magnetic Resonance in Clinical Application and Scientific Research: A National Survey in China.

IF 4.2 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Huaying Zhang, Mengdi Jiang, Wenjing Yang, Di Zhou, Yining Wang, Leyi Zhu, Qiang Zhang Oxford, Arlene Sirajuddin, Andrew E Arai, Shihua Zhao, Xiaohu Li, Xinxiang Zhao, Hui Liu, Hongjie Hu, Min Liu, Yi He, Qi Yang, Yining Wang, Yingkun Guo, Minwen Zheng, Fuhua Yan, Minjie Lu
{"title":"Status of Cardiac Magnetic Resonance in Clinical Application and Scientific Research: A National Survey in China.","authors":"Huaying Zhang, Mengdi Jiang, Wenjing Yang, Di Zhou, Yining Wang, Leyi Zhu, Qiang Zhang Oxford, Arlene Sirajuddin, Andrew E Arai, Shihua Zhao, Xiaohu Li, Xinxiang Zhao, Hui Liu, Hongjie Hu, Min Liu, Yi He, Qi Yang, Yining Wang, Yingkun Guo, Minwen Zheng, Fuhua Yan, Minjie Lu","doi":"10.1016/j.jocmr.2025.101877","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiovascular magnetic resonance (CMR) is rapidly expanding in China, yet comprehensive national data on its clinical application and research status are limited. This study aims to evaluate the current landscape of CMR across the country.</p><p><strong>Methods: </strong>An electronic survey was conducted targeting two groups: physicians trained at the Fuwai Fellowship Program and members of the Chinese Society of Radiology. The survey encompassed details on CMR equipment, clinical practices, and research activities.</p><p><strong>Results: </strong>Of 248 hospitals responded to the survey, 98.0% were tertiary centers. The number of scanners distributed unevenly across geographic regions, with Central South China leading with 5.89/center. Siemens, Philips and GE were top three scanner vendors. Most centers initiated CMR program post-2015. Coronary artery disease was the primary indication for CMR. The median annual volume was 120/center. High-volume centers unevenly concentrated most CMR cases. The weighted average waiting period was 14.2 days, while scan durations ranged from 40 to 60minutes. Two thirds of hospitals used post-processing software to analyze imaging. Half of responding centers included T1 and T2 mapping in clinical routine, but stress perfusion was underutilized in both clinic and research. Approximately one-third of centers had published CMR-related research. The majority of physicians were confident about the development of CMR. Major barriers to CMR development included long scan times, high costs, insufficient equipment, and limited training.</p><p><strong>Conclusions: </strong>CMR is experiencing rapid growth in China but faces significant regional disparities in access to technology and expertise. Efforts to reduce costs, improve training, and expand access to advanced techniques are crucial for balanced development.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"101877"},"PeriodicalIF":4.2000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2025.101877","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cardiovascular magnetic resonance (CMR) is rapidly expanding in China, yet comprehensive national data on its clinical application and research status are limited. This study aims to evaluate the current landscape of CMR across the country.

Methods: An electronic survey was conducted targeting two groups: physicians trained at the Fuwai Fellowship Program and members of the Chinese Society of Radiology. The survey encompassed details on CMR equipment, clinical practices, and research activities.

Results: Of 248 hospitals responded to the survey, 98.0% were tertiary centers. The number of scanners distributed unevenly across geographic regions, with Central South China leading with 5.89/center. Siemens, Philips and GE were top three scanner vendors. Most centers initiated CMR program post-2015. Coronary artery disease was the primary indication for CMR. The median annual volume was 120/center. High-volume centers unevenly concentrated most CMR cases. The weighted average waiting period was 14.2 days, while scan durations ranged from 40 to 60minutes. Two thirds of hospitals used post-processing software to analyze imaging. Half of responding centers included T1 and T2 mapping in clinical routine, but stress perfusion was underutilized in both clinic and research. Approximately one-third of centers had published CMR-related research. The majority of physicians were confident about the development of CMR. Major barriers to CMR development included long scan times, high costs, insufficient equipment, and limited training.

Conclusions: CMR is experiencing rapid growth in China but faces significant regional disparities in access to technology and expertise. Efforts to reduce costs, improve training, and expand access to advanced techniques are crucial for balanced development.

心脏磁共振在临床应用和科学研究中的现状:一项全国调查。
背景:心血管磁共振(CMR)技术在中国发展迅速,但其临床应用和研究现状的全国性综合数据有限。本研究旨在评估全国CMR的现状。方法:采用电子问卷调查的方式,对阜外研修医师和中国放射学会会员进行调查。调查包括CMR设备、临床实践和研究活动的细节。结果:248家受访医院中,三级医院占98.0%。扫描仪数量在地理区域的分布不均匀,以中南地区的5.89台/台居首。西门子、飞利浦和通用电气是前三大扫描仪供应商。大部分中心是在2015年后启动CMR项目的。冠状动脉疾病是CMR的主要适应症。年平均容积为120个/中心。高容量中心不均匀地集中了大多数CMR病例。加权平均等待时间为14.2天,扫描时间从40到60分钟不等。三分之二的医院使用后处理软件来分析图像。一半的应答中心在临床常规中包含T1和T2制图,但在临床和研究中均未充分利用应激灌注。大约三分之一的中心发表了与cmr相关的研究。大多数医生对CMR的发展充满信心。CMR发展的主要障碍包括扫描时间长、成本高、设备不足和培训有限。结论:CMR在中国正在快速增长,但在获取技术和专业知识方面面临着显著的地区差异。努力降低成本、改进培训和扩大获得先进技术的机会对平衡发展至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.90
自引率
12.50%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to: New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system. New methods to enhance or accelerate image acquisition and data analysis. Results of multicenter, or larger single-center studies that provide insight into the utility of CMR. Basic biological perceptions derived by CMR methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信