Diagnostic Performance of Four-Dimensional CT in Preoperative Localization of Primary Hyperparathyroidism.

Q4 Medicine
Wang Man, Wang Yun, Zhang Zhu-Hua, S U Tong, Chen Yu, Jin Zheng-Yu
{"title":"Diagnostic Performance of Four-Dimensional CT in Preoperative Localization of Primary Hyperparathyroidism.","authors":"Wang Man, Wang Yun, Zhang Zhu-Hua, S U Tong, Chen Yu, Jin Zheng-Yu","doi":"10.3881/j.issn.1000-503X.16069","DOIUrl":null,"url":null,"abstract":"<p><p>Objective To evaluate the application value of four-dimensional CT(4D-CT)in the preoperative localization of primary hyperparathyroidism(PHPT). Methods A retrospective analysis was conducted on the clinical data and parathyroid 4D-CT images of 63 patients who underwent PHPT surgery at Peking Union Medical College Hospital between April 2020 and April 2023.Based on the clinical experience of the hospital's surgeons,parathyroid lesions were categorized into six anatomical regions:around the upper pole of the thyroid,posterior to the mid-thyroid,posterior to the lower pole of the thyroid and the tracheoesophageal groove,below the lower pole of the thyroid and the suprasternal fossa,retrosternal anterior mediastinum,and other rare locations.All images were independently analyzed by two experienced radiologists,with discrepancies resolved through discussion led by a senior radiologist.Using pathological results as the gold standard,the accuracy,sensitivity,specificity,positive predictive value(PPV),negative predictive value(NPV),Youden index,positive likelihood ratio(PLR),and negative likelihood ratio(NLR)of preoperative 4D-CT in diagnosing PHPT were calculated. Results There were no statistically significant differences between preoperative 4D-CT and surgical localization in the following regions:around the upper pole of the thyroid(<i>χ<sup>2</sup></i>=0.500,<i>P</i>=0.480),posterior to the mid-thyroid(<i>χ<sup>2</sup></i><0.001,<i>P</i>>0.999),posterior to the lower pole of the thyroid and the tracheoesophageal groove(<i>χ<sup>2</sup></i>=0.571,<i>P</i>=0.450),below the lower pole of the thyroid and the suprasternal fossa(<i>χ<sup>2</sup></i><0.001,<i>P</i>>0.999),retrosternal anterior mediastinum(<i>χ<sup>2</sup></i><0.001,<i>P</i>>0.999),and other rare locations(<i>χ<sup>2</sup></i><0.001,<i>P</i>>0.999).The preoperative 4D-CT diagnosis of PHPT lesions demonstrated a sensitivity of 82.09%,specificity of 97.43%,PPV of 87.30%,NPV of 96.19%,accuracy of 94.71%,Youden index of 79.52%,PLR of 31.94,and NLR of 0.18. Conclusion Parathyroid 4D-CT demonstrates good diagnostic efficacy in the preoperative localization of PHPT.</p>","PeriodicalId":6919,"journal":{"name":"中国医学科学院学报","volume":"47 1","pages":"42-47"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国医学科学院学报","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3881/j.issn.1000-503X.16069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To evaluate the application value of four-dimensional CT(4D-CT)in the preoperative localization of primary hyperparathyroidism(PHPT). Methods A retrospective analysis was conducted on the clinical data and parathyroid 4D-CT images of 63 patients who underwent PHPT surgery at Peking Union Medical College Hospital between April 2020 and April 2023.Based on the clinical experience of the hospital's surgeons,parathyroid lesions were categorized into six anatomical regions:around the upper pole of the thyroid,posterior to the mid-thyroid,posterior to the lower pole of the thyroid and the tracheoesophageal groove,below the lower pole of the thyroid and the suprasternal fossa,retrosternal anterior mediastinum,and other rare locations.All images were independently analyzed by two experienced radiologists,with discrepancies resolved through discussion led by a senior radiologist.Using pathological results as the gold standard,the accuracy,sensitivity,specificity,positive predictive value(PPV),negative predictive value(NPV),Youden index,positive likelihood ratio(PLR),and negative likelihood ratio(NLR)of preoperative 4D-CT in diagnosing PHPT were calculated. Results There were no statistically significant differences between preoperative 4D-CT and surgical localization in the following regions:around the upper pole of the thyroid(χ2=0.500,P=0.480),posterior to the mid-thyroid(χ2<0.001,P>0.999),posterior to the lower pole of the thyroid and the tracheoesophageal groove(χ2=0.571,P=0.450),below the lower pole of the thyroid and the suprasternal fossa(χ2<0.001,P>0.999),retrosternal anterior mediastinum(χ2<0.001,P>0.999),and other rare locations(χ2<0.001,P>0.999).The preoperative 4D-CT diagnosis of PHPT lesions demonstrated a sensitivity of 82.09%,specificity of 97.43%,PPV of 87.30%,NPV of 96.19%,accuracy of 94.71%,Youden index of 79.52%,PLR of 31.94,and NLR of 0.18. Conclusion Parathyroid 4D-CT demonstrates good diagnostic efficacy in the preoperative localization of PHPT.

求助全文
约1分钟内获得全文 求助全文
来源期刊
中国医学科学院学报
中国医学科学院学报 Medicine-Medicine (all)
CiteScore
0.60
自引率
0.00%
发文量
6813
期刊介绍: Acta Academiae Medicinae Sinicae was founded in February 1979. It is a comprehensive medical academic journal published in China and abroad, supervised by the Ministry of Health of the People's Republic of China and sponsored by the Chinese Academy of Medical Sciences and Peking Union Medical College. The journal mainly reports the latest research results, work progress and dynamics in the fields of basic medicine, clinical medicine, pharmacy, preventive medicine, biomedicine, medical teaching and research, aiming to promote the exchange of medical information and improve the academic level of medicine. At present, the journal has been included in 10 famous foreign retrieval systems and their databases [Medline (PubMed online version), Elsevier, EMBASE, CA, WPRIM, ExtraMED, IC, JST, UPD and EBSCO-ASP]; and has been included in important domestic retrieval systems and databases [China Science Citation Database (Documentation and Information Center of the Chinese Academy of Sciences), China Core Journals Overview (Peking University Library), China Science and Technology Paper Statistical Source Database (China Science and Technology Core Journals) (China Institute of Scientific and Technological Information), China Science and Technology Journal Paper and Citation Database (China Institute of Scientific and Technological Information)].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信