Temperature Changes of NaOCl after Irrigation Using Passive Ultrasonic Irrigation, Easy Clean, and XP-Endo Finisher: A Randomized Crossover Clinical Trial.
Geraldo Edson Freitas Athayde de Moraes, Daniel Guimarães Pedro Rocha, Carlos Eduardo Fontana, Rina Andréa Pelegrine, Alexandre Sigrist de Martin, Índia Olinta De Azevedo Queiroz, Carlos Eduardo da Silveira Bueno
{"title":"Temperature Changes of NaOCl after Irrigation Using Passive Ultrasonic Irrigation, Easy Clean, and XP-Endo Finisher: A Randomized Crossover Clinical Trial.","authors":"Geraldo Edson Freitas Athayde de Moraes, Daniel Guimarães Pedro Rocha, Carlos Eduardo Fontana, Rina Andréa Pelegrine, Alexandre Sigrist de Martin, Índia Olinta De Azevedo Queiroz, Carlos Eduardo da Silveira Bueno","doi":"10.1055/s-0044-1791685","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the temperature changes of sodium hypochlorite (NaOCl) after the use of different activation techniques: passive ultrasonic irrigation (PUI), XP-Endo Finisher (XP), and Easy Clean (EC).Thirty patients were selected for this randomized crossover study and each patient received root canal treatment in maxillary incisor. Each tooth was subjected to three activation techniques in a random order in the final irrigation of the treatment. All irrigation was performed using a 2.5% NaOCl solution, with the solution's temperature stabilized at 21°C (baseline) in the syringe. No agitation was used as a control before the use of the devices. After each activation technique, the intracanal temperature was measured using a K-type thermocouple. Statistical analyses were performed using Kruskal-Wallis and Dunn tests.Temperatures remain in the range of 21.0 to 21.2°C at baseline and were higher in the control (29.5-34.1°C), PUI (29.9-34.2°C), EC (29.8-35.6°C), and XP (29.9-34.7°C) groups. The temperature average of the baseline period was inferior to those observed in all groups; moreover, despite of temperature changes among the control and all experimental groups no difference between them were identified.The temperature increase caused by activation with PUI, EC, and XP was similar and did not exceed the levels observed when no agitation was performed.</p>","PeriodicalId":12028,"journal":{"name":"European Journal of Dentistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1791685","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of this study was to evaluate the temperature changes of sodium hypochlorite (NaOCl) after the use of different activation techniques: passive ultrasonic irrigation (PUI), XP-Endo Finisher (XP), and Easy Clean (EC).Thirty patients were selected for this randomized crossover study and each patient received root canal treatment in maxillary incisor. Each tooth was subjected to three activation techniques in a random order in the final irrigation of the treatment. All irrigation was performed using a 2.5% NaOCl solution, with the solution's temperature stabilized at 21°C (baseline) in the syringe. No agitation was used as a control before the use of the devices. After each activation technique, the intracanal temperature was measured using a K-type thermocouple. Statistical analyses were performed using Kruskal-Wallis and Dunn tests.Temperatures remain in the range of 21.0 to 21.2°C at baseline and were higher in the control (29.5-34.1°C), PUI (29.9-34.2°C), EC (29.8-35.6°C), and XP (29.9-34.7°C) groups. The temperature average of the baseline period was inferior to those observed in all groups; moreover, despite of temperature changes among the control and all experimental groups no difference between them were identified.The temperature increase caused by activation with PUI, EC, and XP was similar and did not exceed the levels observed when no agitation was performed.
期刊介绍:
The European Journal of Dentistry is the official journal of the Dental Investigations Society, based in Turkey. It is a double-blinded peer-reviewed, Open Access, multi-disciplinary international journal addressing various aspects of dentistry. The journal''s board consists of eminent investigators in dentistry from across the globe and presents an ideal international composition. The journal encourages its authors to submit original investigations, reviews, and reports addressing various divisions of dentistry including oral pathology, prosthodontics, endodontics, orthodontics etc. It is available both online and in print.