Patrick T Gomella, Joon Yau Leong, Leonard G Gomella, Vivek S Tomar, Hector Teran, Edouard J Trabulsi, Madhukar L Thakur
{"title":"Non-DRE Voided Urine Test to Diagnose Prostate Cancer: Updated Results.","authors":"Patrick T Gomella, Joon Yau Leong, Leonard G Gomella, Vivek S Tomar, Hector Teran, Edouard J Trabulsi, Madhukar L Thakur","doi":"10.3390/diagnostics15050607","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> The standard diagnostic approach for prostate cancer (PCa) diagnosis consists of serum prostate-specific antigen (PSA) testing, digital rectal examination (DRE) and image-guided targeted biopsies. Given the invasive nature, potential adverse events and costs associated with these techniques, alternative approaches have been investigated, specifically with serum and urine assays. The work presented here is intended to further validate a novel noninvasive optical technique for PCa detection, targeting the VPAC genomic receptors that are overexpressed on prostate cancer's malignant cells (MC), in non-DRE voided urine. <b>Methods:</b> Patients (<i>N</i> = 62) who had image-guided biopsy and histologically confirmed localized PCa, and who were scheduled for radical prostatectomy, provided a non-DRE voided urine sample prior to surgery. Urine was cytocentrifuged and cells fixed on a glass slide, incubated with 0.5 μg TP4303 (a receptor-specific fluorophore developed in our laboratory with high affinity for VPAC), excess washed and treated with 4,6-diamidodino-2-phenylindole (DAPI) for nuclear staining. The field of cells on each slide was analyzed using a Zeiss AX10 Observer microscope (20×). The total number of cells and MC were then counted, and the florescent intensity around each MC was measured using Zeiss software. Additionally, non-DRE voided urine samples collected from clinically determined BPH patients (<i>N</i> = 97), were also analyzed similarly. <b>Results:</b> Urine samples from 62 patients were processed and analyzed. Mean PSA levels by Gleason grade (GG) group were 6.5 ± 4.1 ng/mL for GG1 (<i>N</i> = 10), 7.2 ± 3.8 for GG2 (<i>N</i> = 31), 13.2 ± 14.6 for GG3 (<i>N</i> = 13), 6.2 ± 2.2 for GG4 (<i>N</i> = 2) and 50.2 ± 104.9 for GG5 (<i>N</i> = 6). Like the PSA, % MC shed (66.7 ± 27.7) in voided urine and the fluorescent intensity (35.8 ± 5.7) were highest in patients with GG5 prostate cancer. All PCa patients in GG1 to GG5 shed MC in voided urine with increasing % of MC and increasing fluorescence intensity which correlated with the increasing GG for PCa. For BPH, the specificity for the assay was 89.6% (95% CI:81.9-94.9%), PPV was 0.0% and NPV was 100% (95.9% CI, 95.9-100%). <b>Conclusions:</b> These data indicate the following: (i) PCa MC shed in non-DRE voided urine can be detected by targeting VPAC receptors, (ii) MC are shed in non-DRE voided urine with increasing quantity, corresponding to the severity of the disease, and (iii) this non-DRE voided urine optical assay provides a simple, noninvasive, and reliable method for the preliminary detection of PCa with potentially a lower cost than the currently available pre-biopsy detection technologies.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 5","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11899178/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15050607","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The standard diagnostic approach for prostate cancer (PCa) diagnosis consists of serum prostate-specific antigen (PSA) testing, digital rectal examination (DRE) and image-guided targeted biopsies. Given the invasive nature, potential adverse events and costs associated with these techniques, alternative approaches have been investigated, specifically with serum and urine assays. The work presented here is intended to further validate a novel noninvasive optical technique for PCa detection, targeting the VPAC genomic receptors that are overexpressed on prostate cancer's malignant cells (MC), in non-DRE voided urine. Methods: Patients (N = 62) who had image-guided biopsy and histologically confirmed localized PCa, and who were scheduled for radical prostatectomy, provided a non-DRE voided urine sample prior to surgery. Urine was cytocentrifuged and cells fixed on a glass slide, incubated with 0.5 μg TP4303 (a receptor-specific fluorophore developed in our laboratory with high affinity for VPAC), excess washed and treated with 4,6-diamidodino-2-phenylindole (DAPI) for nuclear staining. The field of cells on each slide was analyzed using a Zeiss AX10 Observer microscope (20×). The total number of cells and MC were then counted, and the florescent intensity around each MC was measured using Zeiss software. Additionally, non-DRE voided urine samples collected from clinically determined BPH patients (N = 97), were also analyzed similarly. Results: Urine samples from 62 patients were processed and analyzed. Mean PSA levels by Gleason grade (GG) group were 6.5 ± 4.1 ng/mL for GG1 (N = 10), 7.2 ± 3.8 for GG2 (N = 31), 13.2 ± 14.6 for GG3 (N = 13), 6.2 ± 2.2 for GG4 (N = 2) and 50.2 ± 104.9 for GG5 (N = 6). Like the PSA, % MC shed (66.7 ± 27.7) in voided urine and the fluorescent intensity (35.8 ± 5.7) were highest in patients with GG5 prostate cancer. All PCa patients in GG1 to GG5 shed MC in voided urine with increasing % of MC and increasing fluorescence intensity which correlated with the increasing GG for PCa. For BPH, the specificity for the assay was 89.6% (95% CI:81.9-94.9%), PPV was 0.0% and NPV was 100% (95.9% CI, 95.9-100%). Conclusions: These data indicate the following: (i) PCa MC shed in non-DRE voided urine can be detected by targeting VPAC receptors, (ii) MC are shed in non-DRE voided urine with increasing quantity, corresponding to the severity of the disease, and (iii) this non-DRE voided urine optical assay provides a simple, noninvasive, and reliable method for the preliminary detection of PCa with potentially a lower cost than the currently available pre-biopsy detection technologies.
DiagnosticsBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍:
Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.