{"title":"Agreement between swept-source OCT and Scheimpflug biometers in ocular measurements.","authors":"Cameron McLintock, James McKelvie, Hamed Niyazmand, Samir Uprety","doi":"10.1186/s12886-025-03916-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study evaluated the agreement of the ocular parameters obtained with the two optical biometers, the IOLMaster 700 and the Galilei G6 Lens Professional.</p><p><strong>Patients and methods: </strong>A comparative prospective study was conducted on 159 eyes of 91 adult patients using the IOLMaster 700 and Galilei G6 devices by a single examiner. Agreement between ocular biometric parameters: white-to-white (WTW) distance, keratometry (flat (K1) and steep (K2), mean (Km)) of anterior, posterior, and total corneal surfaces, central corneal thickness (CCT), anterior chamber depth (ACD), and axial length (AL) were assessed using Bland-Altman analysis. Keratometry measurements were further transformed into power vector components J0 and J45 for astigmatism analysis. Clinically significant differences were defined as deviations in biometric parameters translating to differences of 0.25 D or more in refractive outcomes.</p><p><strong>Results: </strong>Statistically and clinically significant difference was identified for ACD (mean difference: -0.15 mm), posterior corneal metrics: K1 (0.39 D), K2 (0.42 D), Km (0.41 D) and J0 (0.05 D) and total corneal metrics: K1 (0.95 D), K2 (0.91 D), Km (0.93 D) and J0 (0.13 D). No significant differences were found for J45 components of posterior and total K, WTW, CCT, and AL measurements.</p><p><strong>Conclusion: </strong>The difference in measurements of anterior chamber depth (ACD), posterior K, and total K metrics are clinically significant making the two devices are clinically significant and not interchangeable. These variation in metrics can impact the refractive outcomes of refractive and cataract surgery with toric IOLs.</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"25 1","pages":"127"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11905573/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-025-03916-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study evaluated the agreement of the ocular parameters obtained with the two optical biometers, the IOLMaster 700 and the Galilei G6 Lens Professional.

Patients and methods: A comparative prospective study was conducted on 159 eyes of 91 adult patients using the IOLMaster 700 and Galilei G6 devices by a single examiner. Agreement between ocular biometric parameters: white-to-white (WTW) distance, keratometry (flat (K1) and steep (K2), mean (Km)) of anterior, posterior, and total corneal surfaces, central corneal thickness (CCT), anterior chamber depth (ACD), and axial length (AL) were assessed using Bland-Altman analysis. Keratometry measurements were further transformed into power vector components J0 and J45 for astigmatism analysis. Clinically significant differences were defined as deviations in biometric parameters translating to differences of 0.25 D or more in refractive outcomes.

Results: Statistically and clinically significant difference was identified for ACD (mean difference: -0.15 mm), posterior corneal metrics: K1 (0.39 D), K2 (0.42 D), Km (0.41 D) and J0 (0.05 D) and total corneal metrics: K1 (0.95 D), K2 (0.91 D), Km (0.93 D) and J0 (0.13 D). No significant differences were found for J45 components of posterior and total K, WTW, CCT, and AL measurements.

Conclusion: The difference in measurements of anterior chamber depth (ACD), posterior K, and total K metrics are clinically significant making the two devices are clinically significant and not interchangeable. These variation in metrics can impact the refractive outcomes of refractive and cataract surgery with toric IOLs.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信