Force control of motion teaching suit using serial-connected pneumatic artificial muscles for actuation and estimation.

IF 3.4 Q2 ENGINEERING, BIOMEDICAL
Wearable technologies Pub Date : 2025-02-26 eCollection Date: 2025-01-01 DOI:10.1017/wtc.2024.30
Tetsuro Miyazaki, Yoshihide Tomita, Kenji Kawashima
{"title":"Force control of motion teaching suit using serial-connected pneumatic artificial muscles for actuation and estimation.","authors":"Tetsuro Miyazaki, Yoshihide Tomita, Kenji Kawashima","doi":"10.1017/wtc.2024.30","DOIUrl":null,"url":null,"abstract":"<p><p>Machine - human interaction systems have been proposed to improve motion learning efficiency. We developed a pneumatic-driven motion teaching system that provides feedback to the learner by simultaneously presenting visual and torque information. We achieved a lightweight, soft, and user-safety haptic system using a pneumatic artificial muscle (PAM). The PAM's shrink force was estimated based on its characteristic model and the suit link system, and the suit generated external torque. However, accurate force control was challenging due to the time delay of the feedback control, the loosening of the soft suit, and modeling errors of the driving PAM caused by hysteresis. To improve the force control performance of the motion teaching suit, this article's contributions are to develop a novel suit in which PAMs for drive and force estimation are connected in series and implement a 2-degree-of-freedom (DOF) force control system using force estimation values in this suit and to confirm the effectiveness of the proposed hardware and software. This article contains three topics: (a) the development of novel suit hardware, (b) force estimation using a sealed small PAM, and (c) a proposal of force control using a 2-DOF controller. The effect of loosening the soft suit is reduced in the novel-developed suit. A sealed small PAM with small deformation and little hysteresis is adopted for force estimation. The time delay in feedback control is decreased by adopting the proposed novel 2-DOF control. Finally, the proposed suit and its control system were evaluated in experiments and achieved the desired performance.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":"6 ","pages":"e10"},"PeriodicalIF":3.4000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11894422/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2024.30","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Machine - human interaction systems have been proposed to improve motion learning efficiency. We developed a pneumatic-driven motion teaching system that provides feedback to the learner by simultaneously presenting visual and torque information. We achieved a lightweight, soft, and user-safety haptic system using a pneumatic artificial muscle (PAM). The PAM's shrink force was estimated based on its characteristic model and the suit link system, and the suit generated external torque. However, accurate force control was challenging due to the time delay of the feedback control, the loosening of the soft suit, and modeling errors of the driving PAM caused by hysteresis. To improve the force control performance of the motion teaching suit, this article's contributions are to develop a novel suit in which PAMs for drive and force estimation are connected in series and implement a 2-degree-of-freedom (DOF) force control system using force estimation values in this suit and to confirm the effectiveness of the proposed hardware and software. This article contains three topics: (a) the development of novel suit hardware, (b) force estimation using a sealed small PAM, and (c) a proposal of force control using a 2-DOF controller. The effect of loosening the soft suit is reduced in the novel-developed suit. A sealed small PAM with small deformation and little hysteresis is adopted for force estimation. The time delay in feedback control is decreased by adopting the proposed novel 2-DOF control. Finally, the proposed suit and its control system were evaluated in experiments and achieved the desired performance.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信