Relationship between intraperitoneal volume and intraperitoneal pressure during peritoneal dialysis-a pilot study in adult patients.

IF 2.2 Q3 PHYSIOLOGY
Fansan Zhu, Laura Rosales Merlo, Lela Tisdale, Maricar Villarama, Jun Yi, Zahin Haq, Xiaoling Wang, Nadja Grobe, Karsten Fischer, Kulwinder Plahey, Richard A Lasher, Paul Chamney, Brigitte Schiller, Peter Kotanko
{"title":"Relationship between intraperitoneal volume and intraperitoneal pressure during peritoneal dialysis-a pilot study in adult patients.","authors":"Fansan Zhu, Laura Rosales Merlo, Lela Tisdale, Maricar Villarama, Jun Yi, Zahin Haq, Xiaoling Wang, Nadja Grobe, Karsten Fischer, Kulwinder Plahey, Richard A Lasher, Paul Chamney, Brigitte Schiller, Peter Kotanko","doi":"10.14814/phy2.70179","DOIUrl":null,"url":null,"abstract":"<p><p>Monitoring intraperitoneal pressure (IPP) offers valuable insights into changes of intraperitoneal volume (IPV) during peritoneal dialysis (PD). This study aims to investigate the relationship between IPV and IPP during a PD dwell. Thirteen patients were studied during a 2-h dwell using 2 L of dialysate containing 2.5% dextrose. IPP was measured using a pressure sensor integrated into an automated PD cycler. IPV was monitored concurrently by segmental bioimpedance (Hydra 4200). The density (ρ) of the PD dialysate was measured using a meter, and the creatinine and glucose concentrations in both dialysate (D) and serum (P) were measured pre- and post-PD dwell. A physical model (IPP = ρ × g × h), was used to describe the relationship between IPP and IPV, where h is the apparent dialysate height and g is the gravitational acceleration. The change in IPP (ΔIPP, -21.2 ± 18%) was mainly determined by the change of h (Δh, -20.9 ± 18.5%), while the change ρ (Δρ, -0.34 ± 0.06%), was minor. The study demonstrated an association between ΔIPP and the ratio of D/P creatinine and D/D<sub>0</sub> glucose, suggesting that ΔIPP may reflect membrane transport characteristics. Due to its noninvasive and seamless nature, the clinical utility of PD cycler-based measurement of IPP warrants further exploration.</p>","PeriodicalId":20083,"journal":{"name":"Physiological Reports","volume":"13 5","pages":"e70179"},"PeriodicalIF":2.2000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11898012/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14814/phy2.70179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Monitoring intraperitoneal pressure (IPP) offers valuable insights into changes of intraperitoneal volume (IPV) during peritoneal dialysis (PD). This study aims to investigate the relationship between IPV and IPP during a PD dwell. Thirteen patients were studied during a 2-h dwell using 2 L of dialysate containing 2.5% dextrose. IPP was measured using a pressure sensor integrated into an automated PD cycler. IPV was monitored concurrently by segmental bioimpedance (Hydra 4200). The density (ρ) of the PD dialysate was measured using a meter, and the creatinine and glucose concentrations in both dialysate (D) and serum (P) were measured pre- and post-PD dwell. A physical model (IPP = ρ × g × h), was used to describe the relationship between IPP and IPV, where h is the apparent dialysate height and g is the gravitational acceleration. The change in IPP (ΔIPP, -21.2 ± 18%) was mainly determined by the change of h (Δh, -20.9 ± 18.5%), while the change ρ (Δρ, -0.34 ± 0.06%), was minor. The study demonstrated an association between ΔIPP and the ratio of D/P creatinine and D/D0 glucose, suggesting that ΔIPP may reflect membrane transport characteristics. Due to its noninvasive and seamless nature, the clinical utility of PD cycler-based measurement of IPP warrants further exploration.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological Reports
Physiological Reports PHYSIOLOGY-
CiteScore
4.20
自引率
4.00%
发文量
374
审稿时长
9 weeks
期刊介绍: Physiological Reports is an online only, open access journal that will publish peer reviewed research across all areas of basic, translational, and clinical physiology and allied disciplines. Physiological Reports is a collaboration between The Physiological Society and the American Physiological Society, and is therefore in a unique position to serve the international physiology community through quick time to publication while upholding a quality standard of sound research that constitutes a useful contribution to the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信