The Use of Shape Memory Alloys in Cages for Cervical Spinal Surgery.

IF 0.9 4区 医学 Q4 CLINICAL NEUROLOGY
F Arlt, D Winkler, N Knoop, M Weidling, F Frank, J Meixensberger, R Grunert
{"title":"The Use of Shape Memory Alloys in Cages for Cervical Spinal Surgery.","authors":"F Arlt, D Winkler, N Knoop, M Weidling, F Frank, J Meixensberger, R Grunert","doi":"10.1055/s-0044-1795156","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> Degenerative changes in the cervical spine can include the gradual loss of functionality of the intervertebral disks, development of osteophytes and ligament hypertrophy. Removal of the intervertebral disk and replacement with a cage (anterior discectomy and fusion [ACDF]) is a standardized operative procedure in these patients. The implant should provide structural support, should restore the physiologic lordosis, and enable a solid fusion. In this context, shape memory materials have great potential in the development of implants in spinal surgery.</p><p><strong>Methods: </strong> We designed and developed a cage that automatically adapts to the cross-section of the intervertebral disk space and simultaneously ensures mechanical support for load transfer between the adjacent vertebral bodies. A special mechanism (shape memory alloy [SMA]) should allow the implant to adapt to the geometric configuration of the intervertebral disk space. The cage developed was tested in an artificial cervical spine.</p><p><strong>Results: </strong> The base body of the cage consists of polyether ether ketone (PEEK) with a width of 14 mm, length of 16 mm, and height of 4 mm. A shape memory actuator, made of nickel-titanium alloy, is used to realize the geometry adaptation. Utilizing this, the transformation from martensite to austenite is completed at 35°C. Biomechanical testing with lateral bending and compression was performed. Subsequent cyclic loading results in a constant hysteresis curve, indicating stable implant positioning.</p><p><strong>Conclusions: </strong> We feel confident about having developed an alternative cage for ACDF that can potentially reduce peri- and postoperative morbidity and provide long-term stability by reducing bone removal during cage implantation. Therefore, we are encouraged to proceed with further biomechanical testing in cadaver specimens to eventually reach the goal of in vivo application.</p>","PeriodicalId":16544,"journal":{"name":"Journal of neurological surgery. Part A, Central European neurosurgery","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurological surgery. Part A, Central European neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/s-0044-1795156","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background:  Degenerative changes in the cervical spine can include the gradual loss of functionality of the intervertebral disks, development of osteophytes and ligament hypertrophy. Removal of the intervertebral disk and replacement with a cage (anterior discectomy and fusion [ACDF]) is a standardized operative procedure in these patients. The implant should provide structural support, should restore the physiologic lordosis, and enable a solid fusion. In this context, shape memory materials have great potential in the development of implants in spinal surgery.

Methods:  We designed and developed a cage that automatically adapts to the cross-section of the intervertebral disk space and simultaneously ensures mechanical support for load transfer between the adjacent vertebral bodies. A special mechanism (shape memory alloy [SMA]) should allow the implant to adapt to the geometric configuration of the intervertebral disk space. The cage developed was tested in an artificial cervical spine.

Results:  The base body of the cage consists of polyether ether ketone (PEEK) with a width of 14 mm, length of 16 mm, and height of 4 mm. A shape memory actuator, made of nickel-titanium alloy, is used to realize the geometry adaptation. Utilizing this, the transformation from martensite to austenite is completed at 35°C. Biomechanical testing with lateral bending and compression was performed. Subsequent cyclic loading results in a constant hysteresis curve, indicating stable implant positioning.

Conclusions:  We feel confident about having developed an alternative cage for ACDF that can potentially reduce peri- and postoperative morbidity and provide long-term stability by reducing bone removal during cage implantation. Therefore, we are encouraged to proceed with further biomechanical testing in cadaver specimens to eventually reach the goal of in vivo application.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
90
期刊介绍: The Journal of Neurological Surgery Part A: Central European Neurosurgery (JNLS A) is a major publication from the world''s leading publisher in neurosurgery. JNLS A currently serves as the official organ of several national neurosurgery societies. JNLS A is a peer-reviewed journal publishing original research, review articles, and technical notes covering all aspects of neurological surgery. The focus of JNLS A includes microsurgery as well as the latest minimally invasive techniques, such as stereotactic-guided surgery, endoscopy, and endovascular procedures. JNLS A covers purely neurosurgical topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信