Patch Fusion: A Novel Ultrafast Multi-Frequency Ultrasound Fusion Imaging Method for Pedicle Screw Navigation.

IF 3 2区 工程技术 Q1 ACOUSTICS
Xiangxin Li, Xueru Yang, Jiaqi Li, Yang Jiao, Jun Shen, Yaoyao Cui, Weiwei Shao
{"title":"Patch Fusion: A Novel Ultrafast Multi-Frequency Ultrasound Fusion Imaging Method for Pedicle Screw Navigation.","authors":"Xiangxin Li, Xueru Yang, Jiaqi Li, Yang Jiao, Jun Shen, Yaoyao Cui, Weiwei Shao","doi":"10.1109/TUFFC.2025.3549842","DOIUrl":null,"url":null,"abstract":"<p><p>Intraosseous ultrasound imaging is valuable for guiding pedicle screw placement in surgery. However, single-frequency ultrasound, whether low or high, often fails to provide both adequate imaging resolution and depth simultaneously. To address this limitation, we introduce a novel ultrafast multi-frequency ultrasound patch fusion imaging method for pedicle screw navigation. This approach combines the strengths of both high-frequency and low-frequency ultrasound images, greatly enhancing the detail and clarity of the resulting images while significantly reducing the time required for image fusion. We validated our method through simulation and ex-vivo experiments, using metrics such as Information Entropy (IE), Spatial Frequency (SF), and Average Gradient (AG) to assess the quality of the fused images. We also recorded the algorithm's execution time. The results demonstrate that our fusion method substantially improves image richness and clarity, enabling a more comprehensive and accurate assessment of the pedicle screw track. Importantly, it also reduces fusion time compared to previous methods, making real-time clinical multi-frequency ultrasound fusion imaging a viable possibility. The in-vivo experimental results of the sheep spinal pedicle screw track further demonstrate the capabilities of the patch fusion method in visualizing the internal conditions of the pedicle screw track and meeting the requirements for real-time fusion imaging. The proposed approach offers substantial support in surgical real-time navigation and ongoing monitoring within the domains of orthopedics and surgery.</p>","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"PP ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TUFFC.2025.3549842","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Intraosseous ultrasound imaging is valuable for guiding pedicle screw placement in surgery. However, single-frequency ultrasound, whether low or high, often fails to provide both adequate imaging resolution and depth simultaneously. To address this limitation, we introduce a novel ultrafast multi-frequency ultrasound patch fusion imaging method for pedicle screw navigation. This approach combines the strengths of both high-frequency and low-frequency ultrasound images, greatly enhancing the detail and clarity of the resulting images while significantly reducing the time required for image fusion. We validated our method through simulation and ex-vivo experiments, using metrics such as Information Entropy (IE), Spatial Frequency (SF), and Average Gradient (AG) to assess the quality of the fused images. We also recorded the algorithm's execution time. The results demonstrate that our fusion method substantially improves image richness and clarity, enabling a more comprehensive and accurate assessment of the pedicle screw track. Importantly, it also reduces fusion time compared to previous methods, making real-time clinical multi-frequency ultrasound fusion imaging a viable possibility. The in-vivo experimental results of the sheep spinal pedicle screw track further demonstrate the capabilities of the patch fusion method in visualizing the internal conditions of the pedicle screw track and meeting the requirements for real-time fusion imaging. The proposed approach offers substantial support in surgical real-time navigation and ongoing monitoring within the domains of orthopedics and surgery.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信