Performance evaluation of a novel MBT LipidART module (Bruker Daltonics) for detection of colistin resistance in Escherichia coli and Klebsiella pneumoniae.
{"title":"Performance evaluation of a novel MBT LipidART module (Bruker Daltonics) for detection of colistin resistance in Escherichia coli and Klebsiella pneumoniae.","authors":"Julija Germ, Mateja Pirs","doi":"10.1007/s10096-025-05099-4","DOIUrl":null,"url":null,"abstract":"<p><p>We evaluated the MBT LipidART module on a MALDI Biotyper® Sirius System (Bruker Daltonics) for the rapid detection of colistin resistance in Escherichia coli (EC) and Klebsiella pneumoniae (KPN) by analysing lipid A profiles in negative ion mode. Categorical agreement was achieved for 98.3% EC (N = 58) and 85.0% KPN (N = 40). Challenges included calibration difficulties, limited availability of compatible equipment and issues with mucoid and adherent KPN isolates that yielded invalid results. While MBT LipidART module shows promise as a rapid tool for detection of colistin resistance, its performance was notably better for EC compared to KPN.</p>","PeriodicalId":11782,"journal":{"name":"European Journal of Clinical Microbiology & Infectious Diseases","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Clinical Microbiology & Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10096-025-05099-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0
Abstract
We evaluated the MBT LipidART module on a MALDI Biotyper® Sirius System (Bruker Daltonics) for the rapid detection of colistin resistance in Escherichia coli (EC) and Klebsiella pneumoniae (KPN) by analysing lipid A profiles in negative ion mode. Categorical agreement was achieved for 98.3% EC (N = 58) and 85.0% KPN (N = 40). Challenges included calibration difficulties, limited availability of compatible equipment and issues with mucoid and adherent KPN isolates that yielded invalid results. While MBT LipidART module shows promise as a rapid tool for detection of colistin resistance, its performance was notably better for EC compared to KPN.
期刊介绍:
EJCMID is an interdisciplinary journal devoted to the publication of communications on infectious diseases of bacterial, viral and parasitic origin.