How much data is enough? Optimization of data collection for artifact detection in EEG recordings.

Lu Wang-Nöth, Philipp Heiler, Hai Huang, Daniel Lichtenstern, Alexandra Reichenbach, Luis Flacke, Linus Maisch, Helmut Mayer
{"title":"How much data is enough? Optimization of data collection for artifact detection in EEG recordings.","authors":"Lu Wang-Nöth, Philipp Heiler, Hai Huang, Daniel Lichtenstern, Alexandra Reichenbach, Luis Flacke, Linus Maisch, Helmut Mayer","doi":"10.1088/1741-2552/adbebe","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Electroencephalography (EEG) is a widely used neuroimaging technique known for its cost-effectiveness and user-friendliness. However, the presence of various artifacts leads to a poor signal-to-noise ratio, limiting the precision of analyses and applications. The proposed work focuses on the electromyography (EMG) artifacts, which are among the most challenging biological artifacts. The currently reported EMG artifact cleaning performance largely depends on the data used for validation, and in the case of machine learning approaches, also on the data used for training. The data are typically gathered either by recruiting subjects to perform specific EMG artifact tasks or by integrating existing datasets. Prevailing approaches, however, tend to rely on intuitive, concept-oriented data collection with minimal justification for the selection of artifacts and their quantities. Given the substantial costs associated with biological data collection and the pressing need for effective data utilization, we propose an optimization procedure for data-oriented data collection design using deep learning-based artifact detection.<i>Approach.</i>We apply a binary classification differentiating between artifact epochs (time intervals containing EMG artifacts) and non-artifact epochs (time intervals containing no EMG artifact) using three different neural architectures. Our aim is to minimize data collection efforts while preserving the cleaning efficiency.<i>Main results.</i>We were able to reduce the number of EMG artifact tasks from twelve to three and decrease repetitions of isometric contraction tasks from ten to three or sometimes even just one.<i>Significance.</i>Our work addresses the need for effective data utilization in biological data collection, offering a systematic and dynamic quantitative approach. By providing clear justifications for the choices of artifacts and their quantity, we aim to guide future studies toward more effective and economical data collection in EEG and EMG research.</p>","PeriodicalId":94096,"journal":{"name":"Journal of neural engineering","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neural engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1741-2552/adbebe","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Electroencephalography (EEG) is a widely used neuroimaging technique known for its cost-effectiveness and user-friendliness. However, the presence of various artifacts leads to a poor signal-to-noise ratio, limiting the precision of analyses and applications. The proposed work focuses on the electromyography (EMG) artifacts, which are among the most challenging biological artifacts. The currently reported EMG artifact cleaning performance largely depends on the data used for validation, and in the case of machine learning approaches, also on the data used for training. The data are typically gathered either by recruiting subjects to perform specific EMG artifact tasks or by integrating existing datasets. Prevailing approaches, however, tend to rely on intuitive, concept-oriented data collection with minimal justification for the selection of artifacts and their quantities. Given the substantial costs associated with biological data collection and the pressing need for effective data utilization, we propose an optimization procedure for data-oriented data collection design using deep learning-based artifact detection.Approach.We apply a binary classification differentiating between artifact epochs (time intervals containing EMG artifacts) and non-artifact epochs (time intervals containing no EMG artifact) using three different neural architectures. Our aim is to minimize data collection efforts while preserving the cleaning efficiency.Main results.We were able to reduce the number of EMG artifact tasks from twelve to three and decrease repetitions of isometric contraction tasks from ten to three or sometimes even just one.Significance.Our work addresses the need for effective data utilization in biological data collection, offering a systematic and dynamic quantitative approach. By providing clear justifications for the choices of artifacts and their quantity, we aim to guide future studies toward more effective and economical data collection in EEG and EMG research.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信