Design and Rationale for the Clinical Investigation of a Novel, Magnetically Levitated Left Ventricular Assist Device for the Treatment of Refractory Heart Failure.

IF 6.4 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Francis D Pagani, Jennifer A Cowger, Ulrich P Jorde, Christopher Salerno, Yoshifumi Naka, Geetha Bhat, Carmelo Milano, Vitaly Druker, James W Long
{"title":"Design and Rationale for the Clinical Investigation of a Novel, Magnetically Levitated Left Ventricular Assist Device for the Treatment of Refractory Heart Failure.","authors":"Francis D Pagani, Jennifer A Cowger, Ulrich P Jorde, Christopher Salerno, Yoshifumi Naka, Geetha Bhat, Carmelo Milano, Vitaly Druker, James W Long","doi":"10.1016/j.healun.2025.03.001","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Contemporary durable left ventricular assist devices (LVAD) have established current benchmarks for patient outcomes, but introduction of more novel technology is lacking. The BrioVAD System (BrioHealth Solutions, Burlington, MA) is an innovative, fully magnetically levitated pump intended to provide short-term (ST) and long-term (LT) mechanical circulatory support.</p><p><strong>Methods: </strong>The Investigation of a Novel, MagNetically Levitated VAD for the Treatment of RefractOry Left Ventricular HeArT FailurE Clinical Trial (INNOVATE) is designed to evaluate safety and efficacy of the BrioVAD by demonstrating non-inferiority to the HeartMate 3 (HM3; Abbott Labs, Chicago, IL). INNOVATE is a multi-center, prospective, non-blinded, randomized (2 BrioVAD: 1 HM3), controlled, non-inferiority study designed as a staged pivotal study with a pre-defined safety phase. Exclusion criteria are designed to enroll a patient population that aligns with contemporary clinical practice. Primary endpoints include a composite of survival to transplant, cardiac recovery, or 6 months (ST) or 24 months (LT) of LVAD support free from debilitating stroke (modified Rankin Scale > 3), or reoperation to replace the pump. A powered secondary outcome evaluates days spent in hospital, skilled nursing facility, or inpatient rehabilitation.</p><p><strong>Results: </strong>INNOVATE study screening and enrollment began in 2024. Completed enrollment of the safety cohort (n = 45) is projected in early 2025. Completion of the ST cohort (n = 237) and LT cohort (n = 402) is projected for 2026 and 2027, respectively.</p><p><strong>Conclusions: </strong>INNOVATE represents a contemporary clinical trial design evaluating unique design features of the BrioVAD System with the expectation to improve patient outcomes.</p>","PeriodicalId":15900,"journal":{"name":"Journal of Heart and Lung Transplantation","volume":" ","pages":""},"PeriodicalIF":6.4000,"publicationDate":"2025-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Heart and Lung Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.healun.2025.03.001","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Contemporary durable left ventricular assist devices (LVAD) have established current benchmarks for patient outcomes, but introduction of more novel technology is lacking. The BrioVAD System (BrioHealth Solutions, Burlington, MA) is an innovative, fully magnetically levitated pump intended to provide short-term (ST) and long-term (LT) mechanical circulatory support.

Methods: The Investigation of a Novel, MagNetically Levitated VAD for the Treatment of RefractOry Left Ventricular HeArT FailurE Clinical Trial (INNOVATE) is designed to evaluate safety and efficacy of the BrioVAD by demonstrating non-inferiority to the HeartMate 3 (HM3; Abbott Labs, Chicago, IL). INNOVATE is a multi-center, prospective, non-blinded, randomized (2 BrioVAD: 1 HM3), controlled, non-inferiority study designed as a staged pivotal study with a pre-defined safety phase. Exclusion criteria are designed to enroll a patient population that aligns with contemporary clinical practice. Primary endpoints include a composite of survival to transplant, cardiac recovery, or 6 months (ST) or 24 months (LT) of LVAD support free from debilitating stroke (modified Rankin Scale > 3), or reoperation to replace the pump. A powered secondary outcome evaluates days spent in hospital, skilled nursing facility, or inpatient rehabilitation.

Results: INNOVATE study screening and enrollment began in 2024. Completed enrollment of the safety cohort (n = 45) is projected in early 2025. Completion of the ST cohort (n = 237) and LT cohort (n = 402) is projected for 2026 and 2027, respectively.

Conclusions: INNOVATE represents a contemporary clinical trial design evaluating unique design features of the BrioVAD System with the expectation to improve patient outcomes.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.10
自引率
6.70%
发文量
1667
审稿时长
69 days
期刊介绍: The Journal of Heart and Lung Transplantation, the official publication of the International Society for Heart and Lung Transplantation, brings readers essential scholarly and timely information in the field of cardio-pulmonary transplantation, mechanical and biological support of the failing heart, advanced lung disease (including pulmonary vascular disease) and cell replacement therapy. Importantly, the journal also serves as a medium of communication of pre-clinical sciences in all these rapidly expanding areas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信