A comparison of the ventilatory responses to wearing either a hood or a mask escape respirator with identical nose-cups.

IF 1.5 4区 医学 Q4 ENVIRONMENTAL SCIENCES
Dror Ofir, Yehuda Arieli, Mirit Eynan, Ben Aviner, Yoav Yanir
{"title":"A comparison of the ventilatory responses to wearing either a hood or a mask escape respirator with identical nose-cups.","authors":"Dror Ofir, Yehuda Arieli, Mirit Eynan, Ben Aviner, Yoav Yanir","doi":"10.1080/15459624.2025.2473463","DOIUrl":null,"url":null,"abstract":"<p><p>Differences in escape respirator design can influence the wearer's ventilatory response and impact inspired oxygen (O<sub>2</sub>) and carbon dioxide (CO<sub>2</sub>) concentrations. There has been minimal investigation into the differences between hood and mask designs as escape respirators that compare between the ventilatory responses of wearing either a hood or mask escape respirator with an identical nose-cup. Thirty-nine healthy young males participated in the study. Each subject participated in two 20-min sessions of monitored breathing, wearing either a hood-type filtering facepiece respirator \"CAPS 2000\" (Shalon Chemical Industries, Israel & Supergum Industries Ltd, Israel) or an \"Orange Diamond\" filtering facepiece mask-type escape respirator (DEA Mop, Israel). Inspired gas concentrations of CO<sub>2</sub> and O<sub>2</sub> as well as the ventilatory response were recorded through a nose-cup during the test. Inspired CO<sub>2</sub>, minute ventilation, breathing frequency, and the index of central ventilatory drive (V<sub>T</sub>/T<sub>I</sub>) were all significantly higher (<i>p</i> < 0.05) while wearing a mask respirator compared to a hood respirator. The hood respirator evaluated in the present study outperformed the mask respirator in most indices when measured at rest. The hood respirator had a reduced ventilatory demand compared to the mask respirator and may be advantageous for individuals with weaker respiratory systems, such as the elderly or those who suffer from respiratory diseases.</p>","PeriodicalId":16599,"journal":{"name":"Journal of Occupational and Environmental Hygiene","volume":" ","pages":"1-7"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Occupational and Environmental Hygiene","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/15459624.2025.2473463","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Differences in escape respirator design can influence the wearer's ventilatory response and impact inspired oxygen (O2) and carbon dioxide (CO2) concentrations. There has been minimal investigation into the differences between hood and mask designs as escape respirators that compare between the ventilatory responses of wearing either a hood or mask escape respirator with an identical nose-cup. Thirty-nine healthy young males participated in the study. Each subject participated in two 20-min sessions of monitored breathing, wearing either a hood-type filtering facepiece respirator "CAPS 2000" (Shalon Chemical Industries, Israel & Supergum Industries Ltd, Israel) or an "Orange Diamond" filtering facepiece mask-type escape respirator (DEA Mop, Israel). Inspired gas concentrations of CO2 and O2 as well as the ventilatory response were recorded through a nose-cup during the test. Inspired CO2, minute ventilation, breathing frequency, and the index of central ventilatory drive (VT/TI) were all significantly higher (p < 0.05) while wearing a mask respirator compared to a hood respirator. The hood respirator evaluated in the present study outperformed the mask respirator in most indices when measured at rest. The hood respirator had a reduced ventilatory demand compared to the mask respirator and may be advantageous for individuals with weaker respiratory systems, such as the elderly or those who suffer from respiratory diseases.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Occupational and Environmental Hygiene
Journal of Occupational and Environmental Hygiene 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
3.30
自引率
10.00%
发文量
81
审稿时长
12-24 weeks
期刊介绍: The Journal of Occupational and Environmental Hygiene ( JOEH ) is a joint publication of the American Industrial Hygiene Association (AIHA®) and ACGIH®. The JOEH is a peer-reviewed journal devoted to enhancing the knowledge and practice of occupational and environmental hygiene and safety by widely disseminating research articles and applied studies of the highest quality. The JOEH provides a written medium for the communication of ideas, methods, processes, and research in core and emerging areas of occupational and environmental hygiene. Core domains include, but are not limited to: exposure assessment, control strategies, ergonomics, and risk analysis. Emerging domains include, but are not limited to: sensor technology, emergency preparedness and response, changing workforce, and management and analysis of "big" data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信