{"title":"Inter- and Intra-Observer Reliability of the New Comprehensive Classification of Intertrochanteric Fracture of the Femur.","authors":"Xiaopei Xu, Yang Liu, Shuo Diao, Junlin Zhou","doi":"10.2147/IJGM.S508342","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the reliability of the new Comprehensive Classification in clinical practice by comparing it with Evans-Jensen (1975), AO/OTA (2007), and AO/OTA (2018).</p><p><strong>Methods: </strong>A total of 192 patients with intertrochanteric fractures were included in the study. The fractures were classified using the Comprehensive Classification system and the three traditional methods by eight observers, consisting of four high-experienced and four less-experienced surgeons. Interobserver and intraobserver agreements were assessed using kappa statistics and compared across the different classification systems.</p><p><strong>Results: </strong>The study included 192 patients. The average inter-observer Kappa values using CT scan for Evans-Jensen (1975), AO/OTA (2007), AO/OTA (2018), and Comprehensive Classification were 0.361 ± 0.06, 0.348 ± 0.05, 0.408 ± 0.06, and 0.492 ± 0.02, respectively. The average inter-observer Kappa values based on 3DR were 0.411 ± 0.04, 0.396 ± 0.03, 0.442 ± 0.03, and 0.524 ± 0.03, respectively. The average intra-observer Kappa values using CT scan were 0.467 ± 0.05, 0.453 ± 0.06, 0.542 ± 0.04, and 0.631 ± 0.02, respectively. The average intra-observer Kappa values using 3DR were 0.503 ± 0.05, 0.482 ± 0.03, 0.561 ± 0.03, and 0.672 ± 0.02, respectively. The mean kappa value of Inter- and intra-observer for the Comprehensive Classification were higher than Evans-Jensen (1975) and AO/OTA (2007/2018) using CT scans and 3DR (P < 0.05). Additionally, the high-experienced group using 3DR had the highest agreement, at approximately 75.86%, when comparing the implant type corresponding to the fracture classification evaluated by the observer with the implant type selected by the observer.</p><p><strong>Conclusion: </strong>The Comprehensive Classification system emerges as a reliable and superior tool for the classification of intertrochanteric fractures, offering improved agreement rates and practical treatment insights compared to traditional methods. This classification has guiding significance for treatment.</p>","PeriodicalId":14131,"journal":{"name":"International Journal of General Medicine","volume":"18 ","pages":"1261-1270"},"PeriodicalIF":2.1000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11892744/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of General Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2147/IJGM.S508342","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To evaluate the reliability of the new Comprehensive Classification in clinical practice by comparing it with Evans-Jensen (1975), AO/OTA (2007), and AO/OTA (2018).
Methods: A total of 192 patients with intertrochanteric fractures were included in the study. The fractures were classified using the Comprehensive Classification system and the three traditional methods by eight observers, consisting of four high-experienced and four less-experienced surgeons. Interobserver and intraobserver agreements were assessed using kappa statistics and compared across the different classification systems.
Results: The study included 192 patients. The average inter-observer Kappa values using CT scan for Evans-Jensen (1975), AO/OTA (2007), AO/OTA (2018), and Comprehensive Classification were 0.361 ± 0.06, 0.348 ± 0.05, 0.408 ± 0.06, and 0.492 ± 0.02, respectively. The average inter-observer Kappa values based on 3DR were 0.411 ± 0.04, 0.396 ± 0.03, 0.442 ± 0.03, and 0.524 ± 0.03, respectively. The average intra-observer Kappa values using CT scan were 0.467 ± 0.05, 0.453 ± 0.06, 0.542 ± 0.04, and 0.631 ± 0.02, respectively. The average intra-observer Kappa values using 3DR were 0.503 ± 0.05, 0.482 ± 0.03, 0.561 ± 0.03, and 0.672 ± 0.02, respectively. The mean kappa value of Inter- and intra-observer for the Comprehensive Classification were higher than Evans-Jensen (1975) and AO/OTA (2007/2018) using CT scans and 3DR (P < 0.05). Additionally, the high-experienced group using 3DR had the highest agreement, at approximately 75.86%, when comparing the implant type corresponding to the fracture classification evaluated by the observer with the implant type selected by the observer.
Conclusion: The Comprehensive Classification system emerges as a reliable and superior tool for the classification of intertrochanteric fractures, offering improved agreement rates and practical treatment insights compared to traditional methods. This classification has guiding significance for treatment.
期刊介绍:
The International Journal of General Medicine is an international, peer-reviewed, open access journal that focuses on general and internal medicine, pathogenesis, epidemiology, diagnosis, monitoring and treatment protocols. The journal is characterized by the rapid reporting of reviews, original research and clinical studies across all disease areas.
A key focus of the journal is the elucidation of disease processes and management protocols resulting in improved outcomes for the patient. Patient perspectives such as satisfaction, quality of life, health literacy and communication and their role in developing new healthcare programs and optimizing clinical outcomes are major areas of interest for the journal.
As of 1st April 2019, the International Journal of General Medicine will no longer consider meta-analyses for publication.