A multicenter validation and calibration of automated software package for detecting anterior circulation large vessel occlusion on CT angiography.

IF 2.2 3区 医学 Q3 CLINICAL NEUROLOGY
Kyu Sun Yum, Jong-Won Chung, Sue Young Ha, Kwang-Yeol Park, Dong-Ick Shin, Hong-Kyun Park, Yong-Jin Cho, Keun-Sik Hong, Jae Guk Kim, Soo Joo Lee, Joon-Tae Kim, Woo-Keun Seo, Oh Young Bang, Gyeong-Moon Kim, Myungjae Lee, Dongmin Kim, Leonard Sunwoo, Hee-Joon Bae, Wi-Sun Ryu, Beom Joon Kim
{"title":"A multicenter validation and calibration of automated software package for detecting anterior circulation large vessel occlusion on CT angiography.","authors":"Kyu Sun Yum, Jong-Won Chung, Sue Young Ha, Kwang-Yeol Park, Dong-Ick Shin, Hong-Kyun Park, Yong-Jin Cho, Keun-Sik Hong, Jae Guk Kim, Soo Joo Lee, Joon-Tae Kim, Woo-Keun Seo, Oh Young Bang, Gyeong-Moon Kim, Myungjae Lee, Dongmin Kim, Leonard Sunwoo, Hee-Joon Bae, Wi-Sun Ryu, Beom Joon Kim","doi":"10.1186/s12883-025-04107-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To validate JLK-LVO, a software detecting large vessel occlusion (LVO) on computed tomography angiography (CTA), within a multicenter dataset.</p><p><strong>Methods: </strong>From 2021 to 2023, we enrolled patients with ischemic stroke who underwent CTA within 24-hour of onset at six university hospitals for validation and calibration datasets and at another university hospital for an independent dataset for testing model calibration. The diagnostic performance was evaluated using area under the curve (AUC), sensitivity, and specificity across the entire study population and specifically in patients with isolated middle cerebral artery (MCA)-M2 occlusion. We calibrated LVO probabilities using logistic regression and by grouping LVO probabilities based on observed frequency.</p><p><strong>Results: </strong>After excluding 168 patients, 796 remained; the mean (SD) age was 68.9 (13.7) years, and 57.7% were men. LVO was present in 193 (24.3%) of patients, and the median interval from last-known-well to CTA was 5.7 h (IQR 2.5-12.1 h). The software achieved an AUC of 0.944 (95% CI 0.926-0.960), with a sensitivity of 89.6% (84.5-93.6%) and a specificity of 90.4% (87.7-92.6%). In isolated MCA-M2 occlusion, the AUROC was 0.880 (95% CI 0.824-0.921). Due to sparse data between 20 and 60% of LVO probabilities, recategorization into unlikely (0-20% LVO scores), less likely (20-60%), possible (60-90%), and suggestive (90-100%) provided a reliable estimation of LVO compared with mathematical calibration. The category of LVO probabilities was associated with follow-up infarct volumes and functional outcome.</p><p><strong>Conclusion: </strong>In this multicenter study, we proved the clinical efficacy of the software in detecting LVO on CTA.</p>","PeriodicalId":9170,"journal":{"name":"BMC Neurology","volume":"25 1","pages":"100"},"PeriodicalIF":2.2000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11892136/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Neurology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12883-025-04107-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To validate JLK-LVO, a software detecting large vessel occlusion (LVO) on computed tomography angiography (CTA), within a multicenter dataset.

Methods: From 2021 to 2023, we enrolled patients with ischemic stroke who underwent CTA within 24-hour of onset at six university hospitals for validation and calibration datasets and at another university hospital for an independent dataset for testing model calibration. The diagnostic performance was evaluated using area under the curve (AUC), sensitivity, and specificity across the entire study population and specifically in patients with isolated middle cerebral artery (MCA)-M2 occlusion. We calibrated LVO probabilities using logistic regression and by grouping LVO probabilities based on observed frequency.

Results: After excluding 168 patients, 796 remained; the mean (SD) age was 68.9 (13.7) years, and 57.7% were men. LVO was present in 193 (24.3%) of patients, and the median interval from last-known-well to CTA was 5.7 h (IQR 2.5-12.1 h). The software achieved an AUC of 0.944 (95% CI 0.926-0.960), with a sensitivity of 89.6% (84.5-93.6%) and a specificity of 90.4% (87.7-92.6%). In isolated MCA-M2 occlusion, the AUROC was 0.880 (95% CI 0.824-0.921). Due to sparse data between 20 and 60% of LVO probabilities, recategorization into unlikely (0-20% LVO scores), less likely (20-60%), possible (60-90%), and suggestive (90-100%) provided a reliable estimation of LVO compared with mathematical calibration. The category of LVO probabilities was associated with follow-up infarct volumes and functional outcome.

Conclusion: In this multicenter study, we proved the clinical efficacy of the software in detecting LVO on CTA.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Neurology
BMC Neurology 医学-临床神经学
CiteScore
4.20
自引率
0.00%
发文量
428
审稿时长
3-8 weeks
期刊介绍: BMC Neurology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of neurological disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信